Evaluation of a fourth-generation focal plane camera for use in plasma-source mass spectrometry

A fourth-generation focal plane camera containing 1696 Faraday-strip detectors was fitted to a Mattauch-Herzog mass spectrograph and characterized for its performance with inductively coupled plasma ionization. The camera provides limits of detection in the single to tens of ng L−1 range for most elements and has a linear dynamic range of at least nine orders of magnitude. Isotope-ratio precision better than 0.02% has also been achieved with this device, and this fourth-generation system features the broadest simultaneous mass range obtainable to date with this family of focal plane camera detectors.

[1]  V. Celo,et al.  High precision determination of silver isotope ratios in commercial products by MC-ICP-MS , 2009 .

[2]  P. Froelich,et al.  Measurement of lithium isotope ratios by quadrupole-ICP-MS: application to seawater and natural carbonates , 2009 .

[3]  G. Hieftje,et al.  Evaluation of a 512-channel Faraday-strip array detector coupled to an inductively coupled plasma Mattauch-Herzog mass spectrograph. , 2009, Analytical chemistry.

[4]  A. Gerdes,et al.  Precise and accurate in situ U-Pb dating of zircon with high sample throughput by automated LA-SF-ICP-MS , 2009 .

[5]  M. B. Denton,et al.  Continuous simultaneous detection in mass spectrometry. , 2007, Analytical chemistry.

[6]  J. Cizdziel Determination of lead in blood by laser ablation ICP-TOF-MS analysis of blood spotted and dried on filter paper: a feasibility study , 2007, Analytical and bioanalytical chemistry.

[7]  James H Barnes,et al.  Characterization of a second-generation focal-plane camera coupled to an inductively coupled plasma Mattauch-Herzog geometry mass spectrograph. , 2006, Analytical chemistry.

[8]  James H. Barnes,et al.  Recent advances in detector-array technology for mass spectrometry , 2004 .

[9]  M. B. Denton,et al.  Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 2. Use with an inductively coupled plasma. , 2004, Analytical chemistry.

[10]  M. B. Denton,et al.  Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 1. Use with a glow-discharge source. , 2002, Analytical chemistry.

[11]  R. Hites,et al.  Design and performance of a plasma-source mass spectrograph , 1997 .

[12]  H. H. Tuithof,et al.  Simultaneous detection of a mass spectrum using a channeltron electron multiplier array , 1975 .