The ear as a location for wearable vital signs monitoring

Obtaining vital signs non-invasively and in a wearable manner is essential for personal health monitoring. We propose the site behind the ear as a location for an integrated wearable vital signs monitor. This location is ideal for both physiological and mechanical reasons. Physiologically, the reflectance photoplethysmograph (PPG) signal behind the ear shows similar signal quality when compared to traditional finger transmission PPG measurements. Ballistocardiogram (BCG) can be obtained behind the ear using 25mm×25mm differential capacitive electrodes constructed using fabric. The BCG signal is able to provide continuous heart rate and respiratory rate, and correlates to cardiac output and blood pressure. Mechanically, the ear remains in the same orientation relative to the heart when upright, thus simplifying pulse transit time calculations. Furthermore, the ear provides a discreet and natural anchoring point that reduces device visibility and the need for adhesives.

[1]  I. Starr,et al.  STUDIES ON THE ESTIMATION OF CARDIAC OUPTUT IN MAN, AND OF ABNORMALITIES IN CARDIAC FUNCTION, FROM THE HEART'S RECOIL AND THE BLOOD'S IMPACTS; THE BALLISTOCARDIOGRAM , 1939 .

[2]  B. Letac,et al.  [Variations in blood pressure at rest and during the day in 40 ambulatory hypertensive patients]. , 1986, Archives des maladies du coeur et des vaisseaux.

[3]  J. McNeil,et al.  Comparison of felodipine extended release and conventional tablets in essential hypertension using ambulatory blood pressure monitoring. , 1989, Journal of hypertension.

[4]  B.H. Jansen,et al.  Monitoring of the ballistocardiogram with the static charge sensitive bed , 1991, IEEE Transactions on Biomedical Engineering.

[5]  R. Kirkpatrick,et al.  Ambulatory Blood Pressure Monitoring , 1993, The Journal of the American Board of Family Medicine.

[6]  L. Kirkup,et al.  A direct comparison of wet, dry and insulating bioelectric recording electrodes. , 2000, Physiological measurement.

[7]  R. Mark,et al.  Computational modeling of cardiovascular response to orthostatic stress. , 2002, Journal of applied physiology.

[8]  A. Varri,et al.  A new method for measuring the ballistocardiogram using EMFi sensors in a normal chair , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  Y. Mendelson,et al.  Measurement reproducibility and sensor placement considerations in designing a wearable pulse oximeter for military applications , 2004, IEEE 30th Annual Northeast Bioengineering Conference, 2004. Proceedings of the.

[10]  Y.T. Zhang,et al.  Wearable medical devices for tele-home healthcare , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  H. Asada,et al.  Novel Design for a Wearable, Rapidly Deployable, Wireless Noninvasive Triage Sensor , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[12]  Francis Eng Hock Tay,et al.  A Long-term Wearable Vital Signs Monitoring System using BSN , 2008, 2008 11th EUROMICRO Conference on Digital System Design Architectures, Methods and Tools.

[13]  H. Harry Asada,et al.  Cuffless Blood Pressure Monitoring Using Hydrostatic Pressure Changes , 2008, IEEE Transactions on Biomedical Engineering.

[14]  Richard M. Wiard,et al.  Robust ballistocardiogram acquisition for home monitoring , 2009, Physiological measurement.

[15]  Marta Di Nicola,et al.  Prognostic value of different indices of blood pressure variability in hypertensive patients. , 2009, American journal of hypertension.

[16]  Kwang Suk Park,et al.  Non-constrained monitoring of systolic blood pressure on a weighing scale , 2009, Physiological measurement.