Comparing AC Dynamic Transients Propagated Through VSC HVDC Connection With Master–Slave Control Versus DC Voltage Droop Control

This paper investigates the propagation of ac dynamic transients through a voltage-source converter-based high-voltage direct current (VSC HVdc) connection, comparing master–slave control and dc voltage droop control, and the impact of the propagation of ac dynamic transients on the small-signal stability of an ac/dc power system is also examined. In this paper, an interconnected model of the ac/dc power system is derived. Analysis using the derived model indicates that under master–slave control, the ac dynamic transients can propagate only unidirectionally through the VSC HVdc connection, and instability from a local ac system may not spread throughout the entire ac/dc power system through the VSC HVdc connection. However, under dc voltage droop control, the propagation becomes bidirectional between the VSCs that participate in the dc voltage droop control, and instability from the local ac system will spread throughout the ac/dc power system. In addition, even if the local ac subsystems are stable, the bidirectional propagation of ac dynamic transients through the VSC HVdc connection may still cause instability. Hence, implementation of dc voltage droop control increases the ac/dc power system's instability risk.

[1]  Lingling Fan,et al.  Impedance-Based Resonance Analysis in a VSC-HVDC System , 2013, IEEE Transactions on Power Delivery.

[2]  Wenjing Ding Self-Excited Vibration , 2010 .

[3]  Shuhui Li,et al.  Optimal and Direct-Current Vector Control of Direct-Driven PMSG Wind Turbines , 2012, IEEE Transactions on Power Electronics.

[4]  Nilanjan Ray Chaudhuri,et al.  System Frequency Support Through Multi-Terminal DC (MTDC) Grids , 2013 .

[5]  Jon Are Suul,et al.  Identification and small-signal analysis of interaction modes in VSC MTDC systems , 2016, 2016 IEEE Power and Energy Society General Meeting (PESGM).

[6]  Lidong Zhang,et al.  Offshore Wind Integration to a Weak Grid by VSC-HVDC Links Using Power-Synchronization Control: A Case Study , 2014, IEEE Transactions on Power Delivery.

[7]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[8]  M. Bongiorno,et al.  Modeling and Analysis of VSC-Based HVDC Systems for DC Network Stability Studies , 2016, IEEE Transactions on Power Delivery.

[9]  Lidong Zhang,et al.  Modeling and Control of VSC-HVDC Links Connected to Island Systems , 2011, IEEE Transactions on Power Systems.

[10]  Alvaro Luna,et al.  A generalized voltage droop strategy for control of multi-terminal DC grids , 2013 .

[11]  Massimo Bongiorno,et al.  Stability Analysis of Two-Terminal VSC-HVDC Systems Using the Net-Damping Criterion , 2016, IEEE Transactions on Power Delivery.

[12]  Xing Zhang,et al.  Analysis and design of vector control for VSC-HVDC connected to weak grids , 2017 .

[13]  W. Marsden I and J , 2012 .

[14]  Graham Rogers,et al.  Power System Oscillations , 1999 .

[15]  Jiuping Pan,et al.  Stability Analysis of VSC MTDC Grids Connected to Multimachine AC Systems , 2011, IEEE Transactions on Power Delivery.

[16]  M. Chinchilla,et al.  Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid , 2006, IEEE Transactions on Energy Conversion.

[17]  Xiao-Ping Zhang,et al.  Basic topology and key devices of the five-terminal DC grid , 2015 .

[18]  O. Anaya-Lara,et al.  Small-Signal Stability Analysis of Multi-Terminal VSC-Based DC Transmission Systems , 2012, IEEE Transactions on Power Systems.