Comparison of the Microflex LT and Vitek MS Systems for Routine Identification of Bacteria by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

ABSTRACT This study compared the performance of three matrix-assisted laser desorption ionization–time of flight mass spectrometry systems: Microflex LT (Bruker Daltonics, Bremen, Germany), Vitek MS RUO (Axima Assurance-Saramis database; bioMérieux, Marcy l'Etoile, France), and Vitek MS IVD (bioMérieux). A total of 1,129 isolates, including 1,003 routine isolates, 73 anaerobes, and 53 bacterial enteropathogens, were tested on the Microflex LT and Axima Assurance devices. The spectra were analyzed using three databases: Biotyper (Bruker Daltonics), Saramis, and Vitek MS (bioMérieux). Among the routine isolates requiring identification to the species level (n = 986), 92.7% and 93.2% were correctly identified by the Biotyper and Vitek MS databases, respectively. The Vitek MS database is more specific for the identification of Streptococcus viridans. For the anaerobes, the Biotyper database often identified Fusobacterium isolates to only the genus level, which is of low clinical significance, whereas 20% of the Bacteroides species were not identified or were misidentified by the Vitek MS database. For the enteropathogens, the poor discrimination between Escherichia coli and Shigella explains the high proportion of unidentified organisms. In contrast to the Biotyper database, the Vitek MS database properly discriminated all of the Salmonella entrica serovar Typhi isolates (n = 5). The performance of the Saramis database was globally poorer. In conclusion, for routine procedures, the Microflex LT and Vitek-MS systems are equally good choices in terms of analytical efficiency. Other factors, including price, work flow, and lab activity, will affect the choice of a system.

[1]  O. Petrini,et al.  Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for the Identification of Clinically Relevant Bacteria , 2011, PloS one.

[2]  D. Raoult,et al.  Ongoing revolution in bacteriology: routine identification of bacteria by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. , 2009, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[3]  C. Stratton,et al.  Improved Identification of Yeast Species Directly from Positive Blood Culture Media by Combining Sepsityper Specimen Processing and Microflex Analysis with the Matrix-Assisted Laser Desorption Ionization Biotyper System , 2011, Journal of Clinical Microbiology.

[4]  M. Kuhns,et al.  Improved clinical laboratory identification of human pathogenic yeasts by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. , 2011, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases.

[5]  P. Murray,et al.  Identification of Mycobacteria in Solid-Culture Media by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry , 2011, Journal of Clinical Microbiology.

[6]  Trinad Chakraborty,et al.  Rapid Identification and Typing of Listeria Species by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry , 2008, Applied and Environmental Microbiology.

[7]  L. Hall,et al.  Performance and Cost Analysis of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Routine Identification of Yeast , 2011, Journal of Clinical Microbiology.

[8]  E. Kuijper,et al.  Comparison of two matrix-assisted laser desorption ionisation-time of flight mass spectrometry methods for the identification of clinically relevant anaerobic bacteria. , 2011, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases.

[9]  M. Maley,et al.  Utility of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry following Introduction for Routine Laboratory Bacterial Identification , 2011, Journal of Clinical Microbiology.

[10]  L. Hoang,et al.  Rapid Identification of Cryptococcus neoformans and Cryptococcus gattii by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry , 2011, Journal of Clinical Microbiology.

[11]  P. Demirev,et al.  Microorganism identification by mass spectrometry and protein database searches. , 1999, Analytical chemistry.

[12]  P. François,et al.  Comparison of Two Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Methods with Conventional Phenotypic Identification for Routine Identification of Bacteria to the Species Level , 2010, Journal of Clinical Microbiology.

[13]  I. Wybo,et al.  Differentiation of cfiA-Negative and cfiA-Positive Bacteroides fragilis Isolates by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry , 2011, Journal of Clinical Microbiology.

[14]  M. Drancourt Detection of microorganisms in blood specimens using matrix-assisted laser desorption ionization time-of-flight mass spectrometry: a review. , 2010, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases.

[15]  A. Bizzini,et al.  Matrix-assisted laser desorption ionization time-of-flight mass spectrometry, a revolution in clinical microbial identification. , 2010, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases.

[16]  M. Tonolla,et al.  Rapid identification of Legionella spp. by MALDI-TOF MS based protein mass fingerprinting. , 2011, Systematic and applied microbiology.

[17]  R. Leuschner,et al.  Difference and consensus of whole cell Salmonella enterica subsp. enterica serovars matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry spectra , 2004, Letters in applied microbiology.

[18]  Etienne Carbonnelle,et al.  MALDI-TOF mass spectrometry tools for bacterial identification in clinical microbiology laboratory. , 2011, Clinical biochemistry.

[19]  A. Mellmann,et al.  High Interlaboratory Reproducibility of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-Based Species Identification of Nonfermenting Bacteria , 2009, Journal of Clinical Microbiology.

[20]  Laura Ferreira,et al.  Identification of Brucella by MALDI-TOF Mass Spectrometry. Fast and Reliable Identification from Agar Plates and Blood Cultures , 2010, PloS one.

[21]  Helen Sutton,et al.  Compilation of a MALDI-TOF mass spectral database for the rapid screening and characterisation of bacteria implicated in human infectious diseases. , 2004, Infection, genetics and evolution : journal of molecular epidemiology and evolutionary genetics in infectious diseases.

[22]  P. Berche,et al.  Matrix-assisted laser desorption ionization time-of-flight mass spectrometry for fast and accurate identification of clinically relevant Aspergillus species. , 2011, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases.

[23]  E. Claas,et al.  High-Throughput Identification of Bacteria and Yeast by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry in Conventional Medical Microbiology Laboratories , 2010, Journal of Clinical Microbiology.

[24]  M. Fisher,et al.  Identification of HACEK Clinical Isolates by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry , 2011, Journal of Clinical Microbiology.

[25]  I. Wybo,et al.  Vitek 2 ANC card versus BBL Crystal Anaerobe and RapID ANA II for identification of clinical anaerobic bacteria. , 2010, Anaerobe.

[26]  M. Skov,et al.  Species Identification of Clinical Isolates of Anaerobic Bacteria: a Comparison of Two Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Systems , 2011, Journal of Clinical Microbiology.

[27]  G Greub,et al.  Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry as an Alternative to 16S rRNA Gene Sequencing for Identification of Difficult-To-Identify Bacterial Strains , 2010, Journal of Clinical Microbiology.

[28]  Karl Wegscheider,et al.  Rapid Identification of Bacteria from Positive Blood Culture Bottles by Use of Matrix-Assisted Laser Desorption-Ionization Time of Flight Mass Spectrometry Fingerprinting , 2010, Journal of Clinical Microbiology.

[29]  N. Lima,et al.  Filamentous fungal characterizations by matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry , 2010, Journal of applied microbiology.

[30]  J. Schrenzel,et al.  Comparative Analysis of PCR–Electrospray Ionization/Mass Spectrometry (MS) and MALDI-TOF/MS for the Identification of Bacteria and Yeast from Positive Blood Culture Bottles , 2011, Clinical chemistry.

[31]  P. Vandamme,et al.  Accuracy of the API Campy system, the Vitek 2 Neisseria-Haemophilus card and matrix-assisted laser desorption ionization time-of-flight mass spectrometry for the identification of Campylobacter and related organisms. , 2011, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases.

[32]  A. Urbani,et al.  MALDI-TOF mass spectrometry proteomic phenotyping of clinically relevant fungi. , 2011, Molecular bioSystems.

[33]  Robin Patel,et al.  Comparison of Bruker Biotyper Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometer to BD Phoenix Automated Microbiology System for Identification of Gram-Negative Bacilli , 2011, Journal of Clinical Microbiology.

[34]  G Greub,et al.  Performance of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Bacterial Strains Routinely Isolated in a Clinical Microbiology Laboratory , 2010, Journal of Clinical Microbiology.