Reconstruction of apparent orthotropic conductivity tensor image using magnetic resonance electrical impedance tomography

Magnetic resonance electrical impedance tomography visualizes current density and/or conductivity distributions inside an electrically conductive object. Injecting currents into the imaging object along at least two different directions, induced magnetic flux density data can be measured using a magnetic resonance imaging scanner. Without rotating the object inside the scanner, we can measure only one component of the magnetic flux density denoted as Bz. Since the biological tissues such as skeletal muscle and brain white matter show strong anisotropic properties, the reconstruction of anisotropic conductivity tensor is indispensable for the accurate observations in the biological systems. In this paper, we propose a direct method to reconstruct an axial apparent orthotropic conductivity tensor by using multiple Bz data subject to multiple injection currents. To investigate the anisotropic conductivity properties, we first recover the internal current density from the measured Bz data. From the recovered ...

[1]  William R B Lionheart,et al.  Uniqueness and reconstruction in magnetic resonance-electrical impedance tomography (MR-EIT). , 2003, Physiological measurement.

[2]  Eung Je Woo,et al.  In Vivo High-ResolutionConductivity Imaging of the Human Leg Using MREIT: The First Human Experiment , 2009, IEEE Transactions on Medical Imaging.

[3]  Y Ziya Ider,et al.  Algebraic reconstruction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density. , 2004, Physiological measurement.

[4]  Harmonic decomposition in PDE-based denoising technique for magnetic resonance electrical impedance tomography , 2005, IEEE Transactions on Biomedical Engineering.

[5]  Byung Il Lee,et al.  In vivo electrical conductivity imaging of a canine brain using a 3 T MREIT system , 2008, Physiological measurement.

[6]  Chunjae Park,et al.  Non-iterative conductivity reconstruction algorithm using projected current density in MREIT. , 2008, Physics in medicine and biology.

[7]  Byung Il Lee,et al.  Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography. , 2003, Physics in medicine and biology.

[8]  Eung Je Woo,et al.  Reconstruction of conductivity using the dual-loop method with one injection current in MREIT. , 2010, Physics in medicine and biology.

[9]  M. Joy,et al.  In vivo detection of applied electric currents by magnetic resonance imaging. , 1989, Magnetic resonance imaging.

[10]  E. Woo,et al.  Identification of current density distribution in electrically conducting subject with anisotropic conductivity distribution. , 2005, Physics in medicine and biology.

[11]  R. Henkelman,et al.  Sensitivity of magnetic-resonance current-density imaging , 1992 .

[12]  Y. Birgül,et al.  Use of the Magnetic Field Generated by the Internal Distribution of Injected Currents for Electrical Impedance Tomography (MR-EIT) , 1998 .

[13]  B. Murat Eyüboglu,et al.  Image Reconstruction in Magnetic Resonance Conductivity Tensor Imaging (MRCTI) , 2012, IEEE Transactions on Medical Imaging.

[14]  Ohin Kwon,et al.  Image reconstruction of anisotropic conductivity tensor distribution in MREIT: computer simulation study. , 2004, Physics in medicine and biology.

[15]  June-Yub Lee A reconstruction formula and uniqueness of conductivity in MREIT using two internal current distributions , 2004 .

[16]  A. Dale,et al.  Conductivity tensor mapping of the human brain using diffusion tensor MRI , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[17]  Byung Il Lee,et al.  Measurement of induced magnetic flux density using injection current nonlinear encoding (ICNE) in MREIT. , 2007, Physiological measurement.

[18]  L. Rudin,et al.  Nonlinear total variation based noise removal algorithms , 1992 .

[19]  M. Ozdemir,et al.  Equipotential projection-based magnetic resonance electrical impedance tomography and experimental realization. , 2004, Physics in medicine and biology.

[20]  Ohin Kwon,et al.  Axial Anisotropic Conductivity Imaging Based on Projected Current Density in MREIT , 2010, IEEE Transactions on Medical Imaging.

[21]  Bin He,et al.  A new magnetic resonance electrical impedance tomography (MREIT) algorithm: the RSM-MREIT algorithm with applications to estimation of human head conductivity , 2006, Physics in medicine and biology.

[22]  Stanley Osher,et al.  Total variation based image restoration with free local constraints , 1994, Proceedings of 1st International Conference on Image Processing.

[23]  Byung Il Lee,et al.  Conductivity imaging with low level current injection using transversal J-substitution algorithm in MREIT. , 2007, Physics in medicine and biology.

[24]  Ozlem Birgul,et al.  Resolution and Contrast in Magnetic Resonance Electrical Impedance Tomography (MREIT) and its Application to Cancer Imaging , 2004, Technology in cancer research & treatment.

[25]  Ozlem Birgul,et al.  Contrast and spatial resolution in MREIT using low amplitude current , 2006, Physics in medicine and biology.

[26]  Ohin Kwon,et al.  Uniqueness and convergence of conductivity image reconstruction in magnetic resonance electrical impedance tomography , 2003 .

[27]  Hyun Soo Nam,et al.  Optimization of multiply acquired magnetic flux density B(z) using ICNE-Multiecho train in MREIT. , 2010, Physics in medicine and biology.

[28]  R M Henkelman,et al.  Measurement of nonuniform current density by magnetic resonance. , 1991, IEEE transactions on medical imaging.

[29]  Ohin Kwon,et al.  Reconstruction of conductivity and current density images using only one component of magnetic field measurements , 2003, IEEE Transactions on Biomedical Engineering.

[30]  Byung Il Lee,et al.  Analysis of recoverable current from one component of magnetic flux density in MREIT and MRCDI , 2007, Physics in medicine and biology.

[31]  Eung Je Woo,et al.  Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging , 2008, Physiological measurement.

[32]  Ohin Kwon,et al.  Equipotential line method for magnetic resonance electrical impedance tomography , 2002 .

[33]  B Murat Eyüboğlu,et al.  Anisotropic conductivity imaging with MREIT using equipotential projection algorithm. , 2007, Physics in medicine and biology.

[34]  Byung Il Lee,et al.  Noise analysis in magnetic resonance electrical impedance tomography at 3 and 11 T field strengths. , 2005, Physiological measurement.

[35]  M.L.G. Joy MR current density and conductivity imaging: the state of the Aart , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[36]  Byung Il Lee,et al.  Three-dimensional forward solver and its performance analysis for magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes. , 2003, Physics in medicine and biology.

[37]  B Murat Eyüboğlu,et al.  Current constrained voltage scaled reconstruction (CCVSR) algorithm for MR-EIT and its performance with different probing current patterns. , 2003, Physics in medicine and biology.

[38]  Eung Je Woo,et al.  Ion mobility imaging and contrast mechanism of apparent conductivity in MREIT. , 2011, Physics in medicine and biology.

[39]  Ohin Kwon,et al.  Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm , 2002, IEEE Transactions on Biomedical Engineering.