Acetylcholinesterase-based biosensors for quantification of carbofuran, carbaryl, methylparaoxon, and dichlorvos in 5% acetonitrile

Amperometric acetylcholinesterase biosensors have been developed for quantification of the pesticides carbofuran, carbaryl, methylparaoxon, and dichlorvos in phosphate buffer containing 5% acetonitrile. Three different biosensors were built using three different acetylcholinesterase (AChE) enzymes—AChE from electric eel, and genetically engineered (B394) and wild-type (B1) AChE from Drosophila melanogaster. Enzymes were immobilized on cobalt(II) phthalocyanine-modified electrodes by entrapment in a photocrosslinkable polymer (PVA-AWP). Each biosensor was tested against the four pesticides. Good operational stability, immobilisation reproducibility, and storage stability were obtained for each biosensor. The best detection limits were obtained with the B394 enzyme for dichlorvos and methylparaoxon (9.6 × 10−11 and 2.7 × 10−9 mol L−1, respectively), the B1 enzyme for carbofuran (4.5 × 10−9 mol L−1), and both the B1 enzyme and the AChE from electric eel for carbaryl (1.6 × 10−7 mol L−1). Finally, the biosensors were used for the direct detection of the pesticides in spiked apple samples.

[1]  K. Courtney,et al.  A new and rapid colorimetric determination of acetylcholinesterase activity. , 1961, Biochemical pharmacology.

[2]  I. H. Segel Enzyme Kinetics: Behavior and Analysis of Rapid Equilibrium and Steady-State Enzyme Systems , 1975 .

[3]  H. Kay Environmental Health Criteria , 1980 .

[4]  Selwayan Saini,et al.  Organic phase enzyme electrodes. , 1990 .

[5]  D. Barceló Environmental analysis : techniques, applications, and quality assurance , 1993 .

[6]  N. Ronzani Effet de solvants sur l'acetylcholinestérase , 1993 .

[7]  Jean-Louis Marty,et al.  Acetylcholinesterase in organic solvents for the detection of pesticides: Biosensor application , 1994 .

[8]  D Barceló,et al.  Determination of organophosphorus pesticides and their transformation products in river waters by automated on-line solid-phase extraction followed by thermospray liquid chromatography-mass spectrometry. , 1995, Journal of chromatography. A.

[9]  D. Barceló,et al.  Improvements in the determination of organophosphorus pesticides in ground- and wastewater samples from interlaboratory studies by automated on-line liquid-solid extraction followed by liquid chromatography-diode array detection , 1996 .

[10]  L. Gorton,et al.  Improvement of Electrochemical Biosensors Using Enzyme Immobilization from Water−Organic Mixtures with a High Content of Organic Solvent , 1996 .

[11]  C. Burstein,et al.  Increased paraoxon detection with solvents using acetylcholinesterase inactivation measured with a choline oxidase biosensor , 1997 .

[12]  M. Mascini,et al.  Determination of anticholinesterase pesticides in real samples using a disposable biosensor , 1997 .

[13]  A. L. Hart,et al.  The response of screen-printed enzyme electrodes containing cholinesterases to organo-phosphates in solution and from commercial formulations , 1997 .

[14]  D. Fournier,et al.  Engineering sensitive acetylcholinesterase for detection of organophosphate and carbamate insecticides. , 1998, Biosensors & bioelectronics.

[15]  Rolf D. Schmid,et al.  A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution , 1999 .

[16]  D. Ivnitski,et al.  A quantitative determination of organophosphate pesticides in organic solvents , 2000 .

[17]  Jean-Louis Marty,et al.  Disposable cholinesterase biosensor for the detection of pesticides in water-miscible organic solvents , 2001 .

[18]  Jean Louis Marty,et al.  Acetylcholine enzyme sensor for determining methamidophos insecticide: Evaluation of some genetically modified acetylcholinesterases from Drosophila melanogaster , 2001 .

[19]  Jean-Louis Marty,et al.  Screen-printed electrode based on AChE for the detection of pesticides in presence of organic solvents. , 2002, Talanta.

[20]  M. Mascini,et al.  Electrochemical bioassay for the investigation of chlorpyrifos-methyl in vine samples. , 2002, Journal of agricultural and food chemistry.

[21]  A. Avramescu,et al.  Detection of organophosphorus insecticides with immobilized acetylcholinesterase – comparative study of two enzyme sensors , 2002, Analytical and bioanalytical chemistry.

[22]  Till T Bachmann,et al.  Design of acetylcholinesterases for biosensor applications. , 2003, Biosensors & bioelectronics.

[23]  Jean-Louis Marty,et al.  Comparative investigation between acetylcholinesterase obtained from commercial sources and genetically modified Drosophila melanogaster: application in amperometric biosensors for methamidophos pesticide detection. , 2004, Biosensors & bioelectronics.

[24]  P. Millner,et al.  Acetylcholinesterase-based biosensor electrodes for organophosphate pesticide detection. I. Modification of carbon surface for immobilization of acetylcholinesterase. , 2004, Biosensors & bioelectronics.

[25]  S. Higson,et al.  Sonochemically fabricated acetylcholinesterase micro-electrode arrays within a flow injection analyser for the determination of organophosphate pesticides. , 2005, Biosensors & bioelectronics.

[26]  J. Marty,et al.  Organophosphorus insecticides extraction and heterogeneous oxidation on column for analysis with an acetylcholinesterase (AChE) biosensor. , 2006, Analytica chimica acta.

[27]  Jean-Louis Marty,et al.  Biosensors based on highly sensitive acetylcholinesterases for enhanced carbamate insecticides detection , 2006 .

[28]  Jean-Louis Marty,et al.  Twenty years research in cholinesterase biosensors: from basic research to practical applications. , 2006, Biomolecular engineering.

[29]  Marinella Sabina Turdean,et al.  Synergetic effect of organic solvents and paraoxon on the immobilized acetylcholinesterase , 2008 .