Application of radiant floor cooling in a large open space building with high-intensity solar radiation

Abstract Radiant floor cooling is suitable for environmental control in large space buildings with high-intensity solar radiation caused by a large transparent envelope. A simple method for predicting the performance of radiant floor cooling systems with solar radiation in steady state is proposed in this paper, and the key factors that influence performance are obtained. Cooling capacity of the radiant floor is significantly increased with high-intensity solar radiation and high-temperature building envelope surfaces in large space buildings. The effect of shelter of indoor furniture (such as chairs) on the performance of radiant floors is analyzed. The lowest floor surface temperature is located at the sheltered floor, and the cooling capacity of the sheltered radiant floor is also lower than that of the unsheltered radiant floor. A case study applying radiant floor cooling in a large space building is then analyzed, and the results are compared with those of a conventional all-air jet ventilation system. At the same indoor air temperature, the radiant cooling system can provide better thermal comfort at a lower operative temperature, and it presents a significant improvement in energy efficiency, with total energy demand 20–30% lower than the conventional all-air system.

[1]  Bjarne W. Olesen,et al.  Low temperature heating and high temperature cooling , 2009 .

[2]  Viktor Dorer,et al.  Interaction of an air system with concrete core conditioning , 1999 .

[3]  S. Holst,et al.  Using radiant cooled floors to condition large spaces and maintain comfort conditions , 2000 .

[4]  K. Ohtaka,et al.  Measurement and evaluation of the indoor thermal environment in a large domed stadium , 2000 .

[5]  B. Olesen,et al.  Experimental evaluation of heat transfer coefficients between radiant ceiling and room , 2009 .

[6]  M.N.A. Saïd,et al.  Measurement of thermal stratification in large single-cell buildings , 1996 .

[7]  D. Int-Hout,et al.  Air distribution for large spaces : Practical guide to HVAC for museums and historic renovation , 1999 .

[8]  Andrzej Górka,et al.  Simulations of floor cooling system capacity , 2013 .

[9]  Andreas K. Athienitis,et al.  The effect of solar radiation on dynamic thermal performance of floor heating systems , 2000 .

[10]  Yi Jiang,et al.  Simplified calculation for cooling/heating capacity, surface temperature distribution of radiant floor , 2012 .

[11]  Dengjia Wang,et al.  Study on heat transfer process for in-slab heating floor , 2012 .

[12]  Chen Huang,et al.  Measurements of indoor thermal environment and energy analysis in a large space building in typical seasons , 2007 .

[13]  Xing Jin,et al.  Numerical simulation of radiant floor cooling system: The effects of thermal resistance of pipe and water velocity on the performance , 2010 .

[14]  Bjarne W. Olesen,et al.  Heat exchange coefficient between floor surface and space by floor cooling -- Theory or a question of definition , 2000 .