Magnetic resonance imaging of shear wave propagation in excised tissue

The propagation of shear waves in ex vivo tissue samples, agar/gel phantoms, and human volunteers was investigated. A moving coil apparatus was constructed to generate low acoustic frequency shear perturbations of 50 to 400 Hz. Oscillating gradients phase‐locked with the shear stimulus were used to generate a series of phase contrast images of the shear waves at different time‐points throughout the wave cycle. Quantitative measurements of wave velocity and attenuation were obtained to evaluate the effects of temperature, frequency, and tissue anisotropy. Results of these experiments demonstrate significant variation in shear wave behavior with tissue type, whereas frequency and anisotropic behavior was mixed. Temperature‐dependent behavior related mainly to the presence of fat. Propagation velocities ranged from 1 to 5 m/sec, and attenuation coefficients of from 1 to 3 nepers/unit wavelength, depending on tissue type. These results confirm the potential of elastic imaging attributable to the intrinsic variability of elastic properties observed in normal tissue, although some difficulty may be experienced in clinical implementation because of viscous attenuation in fat.

[1]  M. O’Donnell,et al.  Theoretical analysis and verification of ultrasound displacement and strain imaging , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  A. Manduca,et al.  Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. , 1995, Science.

[3]  F. Silver Biological Materials: Structure, Mechanical Properties and Modeling of Soft Tissues , 1987 .

[4]  T. Foster,et al.  A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age. , 1984, Medical physics.

[5]  G. Glover,et al.  Encoding strategies for three‐direction phase‐contrast MR imaging of flow , 1991, Journal of magnetic resonance imaging : JMRI.

[6]  D B Plewes,et al.  Visualizing tissue compliance with MR imaging , 1995, Journal of magnetic resonance imaging : JMRI.

[7]  K J Parker,et al.  Tissue response to mechanical vibrations for "sonoelasticity imaging". , 1990, Ultrasound in medicine & biology.

[8]  P. Carson,et al.  Magnetic-resonance imaging techniques for detection of elasticity variation. , 1995, Medical physics.

[9]  B. Garra,et al.  Elastography of breast lesions: initial clinical results. , 1997, Radiology.

[10]  V. Wedeen Magnetic resonance imaging of myocardial kinematics. technique to detect, localize, and quantify the strain rates of the active human myocardium , 1992, Magnetic resonance in medicine.

[11]  J. D. de Certaines,et al.  MR imaging of viscoelastic properties , 1995, Journal of magnetic resonance imaging : JMRI.

[12]  F. S. Vinson,et al.  A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue. , 1987, Journal of rehabilitation research and development.

[13]  R O Potts,et al.  The dynamic mechanical properties of human skin in vivo. , 1983, Journal of biomechanics.

[14]  X. Truong Extensional wave-propagation characteristics in striated muscle. , 1972, The Journal of the Acoustical Society of America.

[15]  J. A. Smith,et al.  Tissue characterization using magnetic resonance elastography , 1997 .

[16]  K. Affeld,et al.  Biomechanical Tissue Properties as an Indicator of Organ Vitality Prior to Transplantations , 1994, The International journal of artificial organs.

[17]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[18]  W. O’Brien,et al.  Young's modulus measurements of soft tissues with application to elasticity imaging , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.