Ultra-miniature fiber-optic pressure sensor using white light interferometry

We have developed a fiber-optic Fabry–Perot interferometric pressure sensor of 125 µm in diameter and a detection system for medical use. A Fabry–Perot cavity is formed at an optical fiber end. A deformation of the diaphragm of the Fabry–Perot cavity induced by pressure varies the cavity length. White light interferometry is used to avoid error and noise caused by bending of the optical fiber and fluctuation of the light source. The reflection light of the sensor cavity is detected by a commercial high-speed spectrometer. A pressure change has been detected by using the developed sensor system. Animal experiments using a goat have been carried out and dynamic pressure changes in the internal pressure of heart and aorta have been successfully monitored.

[1]  Kent A. Murphy,et al.  Wavelength-tracked white light interferometry for highly sensitive strain and temperature measurements , 1996 .

[2]  G. Stemme,et al.  A temperature compensated dual beam pressure sensor , 2002 .

[3]  B. T. Meggitt,et al.  Digital signal-processing techniques for electronically scanned optical-fiber white-light interferometry. , 1992, Applied optics.

[4]  D. Jackson,et al.  Recent progress in fibre optic low-coherence interferometry , 1996 .

[5]  Yunjiang Rao,et al.  A prototype fibre-optic-based Fizeau medical pressure and temperature sensor system using coherence reading , 1994 .

[6]  M. Esashi,et al.  Vacuum sealed ultra miniature fiber-optic pressure sensor using white light interferometry , 2003, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664).

[7]  M. Kohashi,et al.  A fiber-optic pressure microsensor for biomedical applications , 1998 .

[8]  Henry F. Taylor,et al.  Fiber-optic Fabry-Perot temperature sensor using a low-coherence light source , 1991 .

[9]  E. Saaski,et al.  Development of medical pressure and temperature sensors employing optical spectrum modulation , 1991, IEEE Transactions on Biomedical Engineering.

[10]  L. Tenerz,et al.  The first surface micromachined pressure sensor for cardiovascular pressure measurements , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[11]  Joseph T. Boyd,et al.  Novel MEMS pressure and temperature sensors fabricated on optical fibers , 2002 .

[12]  C. Belleville,et al.  White-light interferometric multimode fiber-optic strain sensor. , 1993, Optics letters.

[13]  Y. Haga,et al.  MICROMACHINED 125μm DIAMETER ULTRA MINIATURE FIBER-OPTIC PRESSURE SENSOR FOR CATHETER , 2000 .