Sensitivity analysis aimed at blood vessels detection using interstitial optical tomography during brain needle biopsy procedures.

A brain needle biopsy procedure is performed for suspected brain lesions in order to sample tissue that is subsequently analysed using standard histopathology techniques. A common complication resulting from this procedure is brain hemorrhaging from blood vessels clipped off during tissue extraction. Interstitial optical tomography (iOT) has recently been introduced by our group as a mean to assess the presence of blood vessels in the vicinity of the needle. The clinical need to improve safety requires the detection of blood vessels within 2 mm from the outer surface of the needle, since this distance is representative of the volume of tissue that is aspirated durirng tissue extraction. Here, a sensitivity analysis is presented to establish the intrinsic detection limits of iOT based on simulations and experiments using brain tissue phantoms. It is demonstrated that absorbers can be detected with diameters >300 μm located up to >2 mm from the biopsy needle core for bulk optical properties consistent with brain tissue.

[1]  R. Grossman,et al.  Haemorrhagic complications and the incidence of asymptomatic bleeding associated with stereotactic brain biopsies , 2005, Acta Neurochirurgica.

[2]  Mark Bernstein,et al.  Complications in 622 Cases of Frame-Based Stereotactic Biopsy, a Decreasing Procedure , 2008, Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques.

[3]  C. Avezaat,et al.  Safety and efficacy of frameless and frame-based intracranial biopsy techniques , 2008, Acta Neurochirurgica.

[4]  Johan M. Kros,et al.  Towards improving the safety and diagnostic yield of stereotactic biopsy in a single centre , 2010, Acta Neurochirurgica.

[5]  Frederic Leblond,et al.  System and methods for wide-field quantitative fluorescence imaging during neurosurgery. , 2013, Optics letters.

[6]  R. Price The advantages of frameless stereotactic biopsy over frame-based biopsy , 2003, British journal of neurosurgery.

[7]  V. Seifert,et al.  Intraoperative Bleeding in Stereotactic Biopsies and Its Implication on Postoperative Management: Can We Predict CT Findings? , 2014, Stereotactic and Functional Neurosurgery.

[8]  Frederic Leblond,et al.  Combined fluorescence and reflectance spectroscopy for in vivo quantification of cancer biomarkers in low- and high-grade glioma surgery. , 2011, Journal of biomedical optics.

[9]  Kevin Petrecca,et al.  Sub-diffuse interstitial optical tomography to improve the safety of brain needle biopsies: a proof-of-concept study. , 2015, Optics letters.

[10]  Alfredo Quiñones-Hinojosa,et al.  Frame-based stereotactic biopsy remains an important diagnostic tool with distinct advantages over frameless stereotactic biopsy , 2005, Journal of Neuro-Oncology.

[11]  F. Jolesz,et al.  Survival rates in patients with low‐grade glioma after intraoperative magnetic resonance image guidance , 2005, Cancer.

[12]  Yin-Cheng Huang,et al.  Stereotactic brain biopsy: Single center retrospective analysis of complications , 2009, Clinical Neurology and Neurosurgery.

[13]  Mitchel S Berger,et al.  Impact of extent of resection for recurrent glioblastoma on overall survival: clinical article. , 2012, Journal of neurosurgery.

[14]  M. Kacprzak,et al.  Determination of reference values for optical properties of liquid phantoms based on Intralipid and India ink. , 2014, Biomedical optics express.

[15]  E. Fonoff,et al.  Stereotactic biopsies of brain lesions. , 2009, Arquivos de neuro-psiquiatria.

[16]  D. Thomas,et al.  The advantages of frameless stereotactic biopsy over frame-based biopsy , 2002, British journal of neurosurgery.

[17]  Susan Baldwin,et al.  Compute Canada: Advancing Computational Research , 2012 .

[18]  D. Macarthur,et al.  Stereotactic brain biopsy: an audit of sampling reliabilityin a clinical case series , 2006, British journal of neurosurgery.

[19]  David R. Kaeli,et al.  Accelerating mesh-based Monte Carlo method on modern CPU architectures , 2012, Biomedical optics express.

[20]  K. Ceyhan,et al.  An analysis of stereotactic biopsy of brain tumors and nonneoplastic lesions: a prospective clinicopathologic study. , 2005, Surgical neurology.

[21]  Qianqian Fang,et al.  Mesh-based Monte Carlo method using fast ray-tracing in Plücker coordinates , 2010, Biomedical optics express.

[22]  I. Yaroslavsky,et al.  Optical properties of selected native and coagulated human brain tissues in vitro in the visible and near infrared spectral range. , 2002, Physics in medicine and biology.

[23]  T. Hakan,et al.  Accuracy and diagnostic yield of stereotactic biopsy in the diagnosis of brain masses: Comparison of results of biopsy and resected surgical specimens , 2005, Neuropathology : official journal of the Japanese Society of Neuropathology.