Correlations for Prediction of Mass Transfer Coefficients in Single Drop Systems and Liquid–Liquid Extraction Columns

Empirical correlations for the prediction of mass transfer coefficients for single drops are presented. Published experimental results for both circulating and oscillating drops are considered. Correlation for the individual continuous-phase mass transfer coefficient, which is based on data from 596 measurements taken from 10 different groups of investigators, reproduces the data with an average absolute error of 14.1%. This is then used to determine a correlating equation for the individual dispersed-phase mass transfer coefficient on the basis of data for overall dispersed-phase mass transfer coefficient taken from 21 sources. The average absolute value of the relative error in the predicted values of overall dispersed-phase mass transfer coefficient from the experimental points by using the correlations for individual mass transfer coefficients is 24.5%. It is further shown that by allowing for the effects of power input per unit mass and dispersed-phase hold-up, the correlations for single drops can be extended to extraction columns. The correction factors required for this purpose have been obtained by using simulated values of overall mass transfer coefficients for pulsed perforated-plate, Karr reciprocating-plate, Kuhni, and rotating disc columns.

[1]  B. Berger Scalar particle creation in an anisotropic universe , 1975 .

[2]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[3]  P. Calderbank,et al.  Mass transfer in the continuous phase around axisymmetric bodies of revolution , 1964 .

[4]  R. C. Kintner,et al.  Mass transfer from large oscillating drops , 1966 .

[5]  R. C. Kintner,et al.  Oscillations of drops falling in a liquid field , 1965 .

[6]  R. E. Treybal,et al.  Rate of rise or fall of liquid drops , 1956 .

[7]  J. B. Conway,et al.  Mechanism of Solute Transfer in Spray Towers , 1950 .

[8]  G. A. Hughmark,et al.  Liquid-Liquid Spray Column Drop Size, Holdup, and Continuous Phase Mass Transfer , 1967 .

[9]  D. W. Howard,et al.  Generalization of the penetration theory for surface stretch: Application to forming and oscillating drops , 1966 .

[10]  M. J. Slater,et al.  Liquid-liquid extraction equipment , 1994 .

[11]  S. G. Terjesen,et al.  On the mechanism of mass transfer in liquid-liquid extraction , 1962 .

[12]  N. Cheremisinoff,et al.  Shapes and velocities of single drops and bubbles moving freely through immiscible liquids. , 1976 .

[13]  A. Hamielec,et al.  End effect corrections in heat and mass transfer studies , 1958 .

[14]  R. M. Griffith Mass transfer from drops and bubbles , 1960 .

[15]  Thomas Baron,et al.  Mass and heat transfer from drops in liquid‐liquid extraction , 1957 .

[16]  D. W. Moore,et al.  The motion of a spherical liquid drop at high Reynolds number , 1968, Journal of Fluid Mechanics.

[17]  M. Weber Mass Transfer from Spherical Drops at High Reynolds Numbers , 1975 .

[18]  S. Friedlander A note on transport to spheres in stokes flow , 1961 .

[19]  W. Licht,et al.  Solute Transfer from Single Drops in Liquid-Liquid Extraction , 1953 .

[20]  Sumio Watanabe,et al.  EXPERIMENTAL STUDIES ON MASS TRANSFER RATE AROUND SINGLE OSCILLATING DROPS IN LIQUID-LIQUID SYSTEMS , 1975 .

[21]  R. Clift,et al.  Bubbles, Drops, and Particles , 1978 .

[22]  T. Katayama,et al.  EXPERIMENTAL STUDIES ON MASS TRANSFER IN CONTINUOUS AND DISPERSED PHASES FOR SINGLE DROPS MOVING THROUGH LIQUID FIELD AT INTERMEDIATE REYNOLDS NUMBERS , 1977 .

[23]  Modelling drop-side mass transfer in agitated polydispersed liquid—liquid systems , 1989 .

[24]  S. Hartland,et al.  Prediction of axial mixing coefficients in rotating disc and asymmetric rotating disc extraction columns , 1992 .

[25]  A. Hamielec,et al.  Mass transfer inside drops , 1960 .

[26]  R. J. Brunson,et al.  Mass transfer within oscillating liquid droplets , 1970 .

[27]  S. H. Zhang,et al.  Hydrodynamicst axial mixing and mass transfer in rotating disk contactors , 1981 .

[28]  J. Mecklenburgh,et al.  A comparison of differential and stagewise counter current extraction with backmixing , 1966 .

[29]  A. Bensalem Hydrodynamics and mass transfer in a reciprocating plate extraction column , 1985 .

[30]  A. Skelland,et al.  Extraction with single turbulent droplets , 1965 .

[31]  Peter D. Richardson,et al.  Heat and mass transfer in turbulent separated flows , 1963 .

[32]  A. Hamielec,et al.  Forced convection transfer around spheres at intermediate reynolds numbers , 1962 .

[33]  K. T. Leffek,et al.  SECONDARY KINETIC ISOTOPE EFFECTS IN BIMOLECULAR NUCLEOPHILIC SUBSTITUTIONS: II. α-DEUTERIUM EFFECTS IN MENSCHUTKIN REACTIONS OF METHYL IODIDE , 1965 .

[34]  T. Katayama,et al.  EXPERIMENTAL STUDIES OF MASS TRANSFER RATE IN THE DISPERSED PHASE AND MOVING BEHAVIOR FOR SINGLE OSCILLATING DROPS IN LIQUID-LIQUID SYSTEMS , 1975 .

[35]  S. Hu,et al.  The fall of single liquid drops through water , 1955 .

[36]  L. Boyadzhiev,et al.  On liquid‐liquid mass transfer inside drops in a turbulent flow field , 1969 .

[37]  S. Hartland,et al.  Unified Correlations for the Prediction of Drop Size in Liquid−Liquid Extraction Columns , 1996 .

[38]  A. F. Seibert,et al.  Hydrodynamics and mass transfer in spray and packed liquid-liquid extraction columns , 1988 .

[39]  M. Baird,et al.  Drop phase mass transfer coefficients for liquid—liquid systems and the influence of packings , 1988 .

[40]  P. Calderbank,et al.  Circulation in liquid drops: (A heat-transfer study) , 1956 .

[41]  A. Lochiel The influence of surfactants on mass transfer around spheres , 1965 .

[42]  R. Kronig,et al.  On the theory of extraction from falling droplets II , 1951 .

[43]  M. J. Slater,et al.  A combined model of mass transfer coefficients for contaminated drop liquid‐liquid systems , 1995 .

[44]  A. Skelland,et al.  Resistance to mass transfer inside droplets , 1964 .

[45]  P. M. Heertjes,et al.  Mass transfer between isobutanol and water in a spray-column , 1954 .

[46]  T. Sherwood,et al.  Extraction in Spray and Packed Columns , 1939 .

[47]  A. Hamielec,et al.  Viscous flow around fluid spheres at intermediate reynolds numbers (II) , 1962 .

[48]  G. V. Jeffreys,et al.  A study of mass transfer from single large oscillating drops , 1992 .

[49]  Irving Langmuir,et al.  The Evaporation of Small Spheres , 1918 .

[50]  L. Steiner Mass-transfer rates from single drops and drop swarms , 1986 .

[51]  O. Trass,et al.  Mass transfer from fluid and solid spheres at low Reynolds numbers: Part II , 1962 .