Automated intraoperative calibration for prostate cancer brachytherapy.

PURPOSE Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called "calibration". The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. METHODS A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. RESULTS Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 ± 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 ± 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 ± 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 ± 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. CONCLUSIONS The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

[1]  Pierre Hellier,et al.  A novel temporal calibration method for 3-D ultrasound , 2006, IEEE Transactions on Medical Imaging.

[2]  J. Waterton,et al.  Three-dimensional freehand ultrasound: image reconstruction and volume analysis. , 1997, Ultrasound in medicine & biology.

[3]  R W Prager,et al.  Rapid calibration for 3-D freehand ultrasound. , 1998, Ultrasound in medicine & biology.

[4]  Bruno Siciliano,et al.  Modelling and Control of Robot Manipulators , 1997, Advanced Textbooks in Control and Signal Processing.

[5]  Russell H. Taylor,et al.  Rapid calibration method for registration and 3D tracking of ultrasound images using spatial localizer , 2003, SPIE Medical Imaging.

[6]  L. Collins,et al.  A review of calibration techniques for freehand 3-D ultrasound systems. , 2005, Ultrasound in medicine & biology.

[7]  Robert B. Fisher,et al.  Estimating 3-D rigid body transformations: a comparison of four major algorithms , 1997, Machine Vision and Applications.

[8]  Purang Abolmaesumi,et al.  A real-time freehand ultrasound calibration system with automatic accuracy feedback and control. , 2009, Ultrasound in medicine & biology.

[9]  Jeffrey Siewerdsen,et al.  A dual modality phantom for cone beam CT and ultrasound image fusion in prostate implant. , 2008, Medical physics.

[10]  Gregory D. Hager,et al.  Ultrasound self-calibration , 2006, SPIE Medical Imaging.

[11]  John T. Wei,et al.  Long-term outcomes among localized prostate cancer survivors: health-related quality-of-life changes after radical prostatectomy, external radiation, and brachytherapy. , 2005, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[12]  Albert Goldstein,et al.  Design of Quality Assurance for Sonographic Prostate Brachytherapy Needle Guides , 2002, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[13]  W D Richard,et al.  Three-dimensional imaging with stereotactic ultrasonography. , 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[14]  Po-Wei Hsu,et al.  Real-time freehand 3D ultrasound calibration. , 2008, Ultrasound in medicine & biology.

[15]  K. Cleary,et al.  Image-guided interventions : technology and applications , 2008 .

[16]  J Alison Noble,et al.  Temporal calibration of freehand three-dimensional ultrasound using image alignment. , 2005, Ultrasound in medicine & biology.

[17]  K. Cleary,et al.  Image Guided Interventions. , 2020, Biomedizinische Technik. Biomedical engineering.

[18]  Dinesh K Pai,et al.  Surface extraction with a three-dimensional freehand ultrasound system. , 2004, Ultrasound in medicine & biology.

[19]  David J. Hawkes,et al.  Self-calibrating 3D-ultrasound-based bone registration for minimally invasive orthopedic surgery , 2006, IEEE Transactions on Medical Imaging.

[20]  Marco Zaider,et al.  Five-year outcome of intraoperative conformal permanent I-125 interstitial implantation for patients with clinically localized prostate cancer. , 2007, International journal of radiation oncology, biology, physics.

[21]  Gregory D. Hager,et al.  Real-Time Quality Control of Tracked Ultrasound , 2005, MICCAI.

[22]  Frank Lindseth,et al.  A robust and automatic method for evaluating accuracy in 3-D ultrasound-based navigation. , 2003, Ultrasound in medicine & biology.

[23]  Andrew H. Gee,et al.  Stradx: real-time acquisition and visualization of freehand three-dimensional ultrasound , 1999, Medical Image Anal..

[24]  Ivar Jacobson,et al.  Unified Modeling Language User Guide, The (2nd Edition) (Addison-Wesley Object Technology Series) , 2005 .

[25]  Thomas Langø,et al.  Probe calibration for freehand 3-D ultrasound. , 2003, Ultrasound in medicine & biology.

[26]  S Meairs,et al.  Reconstruction and visualization of irregularly sampled three- and four-dimensional ultrasound data for cerebrovascular applications. , 2000, Ultrasound in medicine & biology.

[27]  J. Blasko,et al.  Initial analysis of Pro-Qura: a multi-institutional database of prostate brachytherapy dosimetry. , 2007, Brachytherapy.

[28]  A. Jemal,et al.  Global Cancer Statistics , 2011 .

[29]  Purang Abolmaesumi,et al.  A mutual-information-based registration algorithm for ultrasound-guided computer-assisted orthopaedic surgery , 2005, SPIE Medical Imaging.

[30]  John T. Wei,et al.  Comprehensive comparison of health-related quality of life after contemporary therapies for localized prostate cancer. , 2002, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[31]  S Mutic,et al.  A simple technique for alignment of perineal needle template to ultrasound image grid for permanent prostate implants. , 2000, Medical physics.

[32]  Laurence Mercier,et al.  A review of calibration techniques for freehand 3-D ultrasound systems. , 2005, Ultrasound in medicine & biology.

[33]  Graham M. Treece,et al.  High-definition freehand 3-D ultrasound. , 2003, Ultrasound in medicine & biology.

[34]  A system for ultrasound-guided computer-assisted orthopaedic surgery , 2005, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[35]  Yoshikazu Nakajima,et al.  A temporal calibration method for freehand 3D ultrasound system: a preliminary result , 2003, Computer Assisted Radiology and Surgery - International Congress and Exhibition.

[36]  Purang Abolmaesumi,et al.  A real-time ultrasound calibration system with automatic accuracy control and incorporation of ultrasound section thickness , 2008, SPIE Medical Imaging.

[37]  D M Muratore,et al.  Beam calibration without a phantom for creating a 3-D freehand ultrasound system. , 2001, Ultrasound in medicine & biology.

[38]  N Pagoulatos,et al.  A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer. , 2001, Ultrasound in medicine & biology.

[39]  Gabor Fichtinger,et al.  Bootstrapped ultrasound calibration. , 2006, Studies in health technology and informatics.

[40]  D. Parkin,et al.  Global cancer statistics in the year 2000. , 2001, The Lancet. Oncology.