A novel control strategy of a distributed generator operating in seven modes for ancillary services under grid faults

Abstract This study was interested in a renewable distributed generator (RDG) made up of a wind turbine used as a principal source and a supercapacitor (SC) considered as a storage system. The studied RDG is associated with loads to constitute a micro-grid (MG) which can operate in grid connected mode, stand alone mode or synchronization mode. The objective of this work is to investigate a novel control scheme for MG integrated into power electrical system in order to maintain the voltage and the frequency of the grid in an allowable range and to ensure the continuity of power supply in case of grid failure. This control strategy made up of two parts: the first one is the power management algorithm used to detect islanding in case of defect and to monitor the RDG into seven operating modes. The second one is the droop control used to control the exported or imported active and reactive powers transferred with the grid ensuring its stability by adjusting the frequency and amplitude of its output voltage. The system is simulated using MATLAB software and results are provided in order to show the feasibility of this control strategy.

[1]  Stéphane Raël,et al.  Voltage regulated hybrid DC power source using supercapacitors as energy storage device , 2007 .

[2]  Lotfi Krichen,et al.  Electric power generation based on variable speed wind turbine under load disturbance , 2011 .

[3]  R. Mark Nelms,et al.  Classical equivalent circuit parameters for a double-layer capacitor , 2000, IEEE Trans. Aerosp. Electron. Syst..

[4]  Liuchen Chang,et al.  An intelligent maximum power extraction algorithm for inverter-based variable speed wind turbine systems , 2004 .

[5]  G. Joos,et al.  Supercapacitor Energy Storage for Wind Energy Applications , 2007, IEEE Transactions on Industry Applications.

[6]  Whei-Min Lin,et al.  Hybrid intelligent control of PMSG wind generation system using pitch angle control with RBFN , 2011 .

[7]  Ahmed M. Kassem Robust voltage control of a stand alone wind energy conversion system based on functional model predictive approach , 2012 .

[8]  Mehdi Savaghebi,et al.  Selective compensation of voltage harmonics in grid-connected microgrids , 2013, Math. Comput. Simul..

[9]  Jin Jiang,et al.  Control and load-dispatching strategies for a microgrid with a DC/AC inverter of fixed frequency , 2012 .

[10]  F. Dinçer,et al.  The analysis on wind energy electricity generation status, potential and policies in the world , 2011 .

[11]  Hu Yi,et al.  A Two-level Energy Storage System for Wind Energy Systems , 2012 .

[12]  Jure Margeta,et al.  Vision of total renewable electricity scenario , 2011 .

[13]  Daryoush Habibi,et al.  Power quality improvement in autonomous microgrid operation using particle swarm optimization , 2011 .

[14]  Arindam Ghosh,et al.  Operation and control of a hybrid microgrid containing unbalanced and nonlinear loads , 2010 .

[15]  Fang Hongwei,et al.  Impacts of P-f & Q-V Droop Control on MicroGrids Transient Stability , 2012 .

[16]  Juan C. Vasquez,et al.  Adaptive Droop Control Applied to Voltage-Source Inverters Operating in Grid-Connected and Islanded Modes , 2009, IEEE Transactions on Industrial Electronics.

[17]  Giuseppe Lo Re,et al.  An execution, monitoring and replanning approach for optimal energy management in microgrids , 2011 .

[18]  Ting-Chia Ou,et al.  A novel unsymmetrical faults analysis for microgrid distribution systems , 2012 .

[19]  J. McDowall,et al.  Integrating energy storage with wind power in weak electricity grids , 2006 .

[20]  H. Polinder,et al.  General Model for Representing Variable-Speed Wind Turbines in Power System Dynamics Simulations , 2002, IEEE Power Engineering Review.

[21]  K.. De Brabandere,et al.  A Voltage and Frequency Droop Control Method for Parallel Inverters , 2007, IEEE Transactions on Power Electronics.

[22]  Fernando Briz,et al.  An improved control scheme based in droop characteristic for microgrid converters , 2010 .

[23]  Benoit Robyns,et al.  Experimental study of variable speed wind generator contribution to primary frequency control , 2009 .

[24]  R. Mark Nelms,et al.  Analysis of double-layer capacitors supplying constant power loads , 2000, IEEE Trans. Aerosp. Electron. Syst..

[25]  S. P. Chowdhury,et al.  UK scenario of islanded operation of active distribution networks with renewable distributed generators , 2011 .