Attenuation correction in cardiac SPECT without a transmission measurement.

UNLABELLED The accuracy of SPECT cardiac perfusion imaging is impaired by artifacts induced by nonuniform gamma-ray attenuation. This study proposes a method to estimate attenuation in the chest of patients without the additional hardware and expense of transmission imaging. METHODS After the standard 201Tl or 99mTc-sestamibi delayed images were obtained, 99mTc macroaggregated albumin (MAA) was injected and dual-energy SPECT acquisition was performed with windows centered at 140 keV and 94 keV. Lung contours were obtained by thresholding the on-peak (140 keV) reconstructions. Outer body contours were defined from images produced by reconstruction of the lower energy scatter window obtained simultaneously at the time of the lung (MAA) imaging. Following assignment of standard attenuation values to the lung and nonlung (soft tissue) regions attenuation correction was achieved by means of a modified iterative Chang algorithm. The results were quantitatively evaluated by imaging of a cardiac phantom filled with uniform activity placed in a chest phantom. Sensitivity to the choice of lung and soft tissue attenuation values, the choice of the threshold used for lung segmentation, and errors in registration of the attenuation map were assessed. RESULTS Application of this technique in a chest phantom and in patients imaged with both 201Tl and 99mTc-sestamibi resulted in improvement in artifactually decreased inferior wall activity without adversely affecting the other walls. The results were relatively insensitive to choice of values for lung and soft-tissue attenuation, lung thresholding, and small (< or = 1.3 cm) registration errors. CONCLUSION This simple method corrects for nonuniform attenuation in males; studies are underway to adapt the method to determine breast contour in females and to determine the value of the method in clinical practice.

[1]  F D Thomas,et al.  Imaging of the human torso using cone-beam transmission CT implemented on a rotating gamma camera. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  N. Mullani,et al.  A segmented attenuation correction for PET. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  M. Miller,et al.  Maximum-Likelihood Reconstruction for Single-Photon Emission Computed-Tomography , 1985, IEEE Transactions on Nuclear Science.

[4]  Michael E. Phelps,et al.  Physics in nuclear medicine. Second edition , 1987 .

[5]  F D Thomas,et al.  Phantom study of breast tissue attenuation in myocardial imaging. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.