Graphene Encapsulated Copper Microwires as Highly MRI Compatible Neural Electrodes.

Magnetic resonance imaging (MRI) compatible neural electrodes are important for combining high-resolution electrophysiological measurements with more global MRI mapping of brain activity, which is critical for fundamental neuroscience studies, as well as clinical evaluation and monitoring. Copper is a favorable material to use in MRI because it has magnetic susceptibility close to water and tissues. However, the cytotoxicity of copper precludes its direct implantation for neural recording. Here, we overcome this limitation by developing a graphene encapsulated copper (G-Cu) microelectrode. The toxicity of copper is largely eliminated, as evidenced by the in vitro cell tests and in vivo histology studies. Local field potentials and single-unit spikes were recorded from rodent brains with the G-Cu microelectrodes. Notably, the G-Cu microelectrodes show no image artifacts in a 7.0 T MRI scanner, indicating minimal magnetic field distortion in their vicinity. This high MRI compatibility of our G-Cu probes would open up new opportunities for fundamental brain activity studies and clinical applications requiring continuous MRI and electrophysiological recordings.

[1]  Changqing Jiang,et al.  Artifact properties of carbon nanotube yarn electrode in magnetic resonance imaging , 2013, Journal of neural engineering.

[2]  Kwang S. Kim,et al.  Large-scale pattern growth of graphene films for stretchable transparent electrodes , 2009, Nature.

[3]  Frank Bihari,et al.  MRI compatible EEG electrode system for routine use in the epilepsy monitoring unit and intensive care unit , 2004, Clinical Neurophysiology.

[4]  Enge Wang,et al.  Ultrafast growth of single-crystal graphene assisted by a continuous oxygen supply. , 2016, Nature nanotechnology.

[5]  Nicole C. Swann,et al.  Therapeutic deep brain stimulation reduces cortical phase-amplitude coupling in Parkinson's disease , 2015, Nature Neuroscience.

[6]  Suzanne S. Stensaas,et al.  Histopathological evaluation of materials implanted in the cerebral cortex , 1978, Acta Neuropathologica.

[7]  David C. Martin,et al.  Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays , 2005, Experimental Neurology.

[8]  Nicholas V. Annetta,et al.  Restoring cortical control of functional movement in a human with quadriplegia , 2016, Nature.

[9]  Patrick A Tresco,et al.  Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortex. , 2010, Biomaterials.

[10]  Yei Hwan Jung,et al.  Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics , 2013, Science.

[11]  William Regan,et al.  Graphene as a long-term metal oxidation barrier: worse than nothing. , 2013, ACS nano.

[12]  Paul S. Weiss,et al.  The Brain Activity Map , 2013, Science.

[13]  D. Kipke,et al.  Neural probe design for reduced tissue encapsulation in CNS. , 2007, Biomaterials.

[14]  Jianbo Yin,et al.  Selectively enhanced photocurrent generation in twisted bilayer graphene with van Hove singularity , 2016, Nature Communications.

[15]  P. Tresco,et al.  Response of brain tissue to chronically implanted neural electrodes , 2005, Journal of Neuroscience Methods.

[16]  Andre K. Geim,et al.  Raman spectrum of graphene and graphene layers. , 2006, Physical review letters.

[17]  Zhongfan Liu,et al.  Surface Engineering of Copper Foils for Growing Centimeter-Sized Single-Crystalline Graphene. , 2016, ACS Nano.

[18]  Tao Zhou,et al.  Stable long-term chronic brain mapping at the single-neuron level , 2016, Nature Methods.

[19]  J. Schenck The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. , 1996, Medical physics.

[20]  Petros Martirosian,et al.  Metal artifacts caused by gradient switching , 2005, Magnetic resonance in medicine.

[21]  Bejoy Thomas,et al.  Principles, techniques, and applications of T2*-based MR imaging and its special applications. , 2009, Radiographics : a review publication of the Radiological Society of North America, Inc.

[22]  Edson Amaro,et al.  Performing functional magnetic resonance imaging in patients with Parkinson's disease treated with deep brain stimulation , 2006, Movement disorders : official journal of the Movement Disorder Society.

[23]  S. Banerjee,et al.  Large-Area Synthesis of High-Quality and Uniform Graphene Films on Copper Foils , 2009, Science.

[24]  G. Buzsáki,et al.  Hippocampal network patterns of activity in the mouse , 2003, Neuroscience.

[25]  C. Lieber,et al.  Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes. , 2015, Nature materials.

[26]  N. Logothetis,et al.  Neurophysiological investigation of the basis of the fMRI signal , 2001, Nature.

[27]  Mark R. Bower,et al.  Microseizures and the spatiotemporal scales of human partial epilepsy. , 2010, Brain : a journal of neurology.

[28]  M. Jahanshahi,et al.  MRI-guided STN DBS in Parkinson's disease without microelectrode recording: efficacy and safety , 2010, Journal of Neurology, Neurosurgery & Psychiatry.

[29]  D. Losic,et al.  Graphene: a multipurpose material for protective coatings , 2015 .

[30]  K. Bolotin,et al.  Graphene: corrosion-inhibiting coating. , 2012, ACS nano.