Double trouble

This article presents the modeling, simulation, and practical application of a double-fed asynchronous motor-generator for pumped-storage plants equipped with a three-level VSI cascade. The problem of DC unbalance control is studied in this particular application. A solution is proposed and tested in practice. This solution uses a specific adaptable filter and is based on the injection of the second order harmonic. A method for determining the critical point has been developed. It ensures the correct action of the regulator over the whole operating range. This important aspect has also been validated. A sensorless method is presented for the determination of the rotor angle, which is needed in the control strategy. Measurements performed on a low-power system validate the method. Finally, comparisons between simulations and measurements performed on a low-power system validate not only the complete control strategy but also the DC unbalance control, the sensorless method, and the modeling of the overall system. This study provides a useful basis for an optimized design of a large variable speed motor-generator equipped with a three-level VSI cascade.

[1]  Z. Krzeminski Sensorless multiscalar control of double fed machine for wind power generators , 2002, Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579).

[2]  J.-J. Simond,et al.  Double-fed asynchronous motor-generator equipped with a 3-level VSI cascade , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[3]  Catherine D. Wolfram,et al.  Measuring Duopoly Power in the British Electricity Spot Market , 1999 .

[4]  Jean-Jacques Simond,et al.  Adjustable speed asynchronous machine in hydro power plants and its advantages for the electric grid stability. , 1998 .

[5]  S. Borenstein,et al.  An Empirical Analysis of the Potential for Market Power in California&Apos;S Electricity Industry , 1998 .

[6]  A. Sapin,et al.  Expected benefits of adjustable speed pumped storage in the European network. , 1999 .

[7]  S. Borenstein,et al.  Measuring Market Inefficiencies in California's Restructured Wholesale Electricity Market , 2002 .

[8]  George Hendrikse,et al.  The Theory of Industrial Organization , 1989 .

[9]  The Fall in British Electricity Prices: Market Rules, Market Structure, or Both? , 2003 .

[10]  R. Green,et al.  Competition in the British Electricity Spot Market , 1992, Journal of Political Economy.

[11]  A. Hodder,et al.  Investigation and comparison between classical and state-space control for the entry VSI of a frequency converter. , 2002 .

[12]  J. M. Kauffmann,et al.  Double-fed induction machine: converter optimisation and field oriented control without position sensor , 1998 .