Simultaneous detection of antibodies to cytomegalovirus and herpes simplex virus by using flow cytometry and a microsphere-based fluorescence immunoassay

A sensitive assay for the simultaneous detection of anti-cytomegalovirus and anti-herpes simplex virus antibodies was developed. Two different sizes of polystyrene microspheres were coated with purified viral antigens. Human antiviral antibodies were detected with a biotin-streptavidin amplification procedure with phycoerythrin as the fluorescent label. Microsphere-associated fluorescence was quantitated with a flow cytometer. Sixteen percent of samples initially scored as seronegative for cytomegalovirus and 35% of samples initially scored as seronegative for herpes simplex virus by conventional assays were clearly found positive by the microsphere technique. This flow cytometric assay can simultaneously detect several specific antibodies at levels which are below the sensitivity of standard assays. The dynamic range of this assay is at least sixfold greater than that of enzyme immunoassays. This technique is amenable to numerous serologic assays and could greatly expand the clinical laboratory applications of flow cytometry.

[1]  A. Nahmias,et al.  Detection of antibodies to herpes simplex virus in the cerebrospinal fluid of patients with herpes simplex encephalitis. , 1987, The Journal of infectious diseases.

[2]  J. Baggett,et al.  Prevention of transfusion‐associated cytomegalovirus infection in very low‐birthweight infants using frozen blood and donors seronegative for cytomegalovirus , 1984, Transfusion.

[3]  N. Keiding,et al.  GRAFT-VERSUS-LEUKAEMIA ACTIVITY ASSOCIATED WITH CYTOMEGALOVIRUS ANTIBODY POSITIVE BONE MARROW DONORS IN ACUTE MYELOID LEUKAEMIA , 1987, The Lancet.

[4]  D. Stites,et al.  Effects of interleukin 2 and large envelope glycoprotein (gp 120) of human immunodeficiency virus (HIV) on lymphocyte proliferative responses to cytomegalovirus. , 1988, Clinical and experimental immunology.

[5]  M. Kronick,et al.  The use of phycobiliproteins as fluorescent labels in immunoassay. , 1986, Journal of immunological methods.

[6]  J H Jett,et al.  Amplified flow-cytometric separation-free fluorescence immunoassays. , 1985, Clinical chemistry.

[7]  S. Kohl,et al.  Defective production of antibody to herpes simplex virus in neonates: defective production of T helper lymphokine and induction of suppression. , 1987, The Journal of infectious diseases.

[8]  D. Stites,et al.  Detection of the Human Erythrocyte Surface Antigen Gerbich by Flow Cytometry using Human Antibodies and Phycoerythrin for Extreme Immunofluorescence Sensitivity , 1987, Vox sanguinis.

[9]  L. Corey,et al.  Detection of asymptomatic herpes simplex virus infections after vaccination , 1987, Journal of virology.

[10]  J. Grundy,et al.  Radioimmunoassay for the detection of IgG antibodies to herpes simplex virus and its use as a prognostic indicator of HSV excretion in transplant recipients , 1987, Journal of medical virology.

[11]  L. Wheeless,et al.  Quantitative single cell analysis and sorting. , 1977, Science.

[12]  L. Hutt-Fletcher,et al.  Antigenic cross-reactions among herpes simplex virus types 1 and 2, Epstein-Barr virus, and cytomegalovirus , 1987, Journal of virology.

[13]  B. Wahrén,et al.  Sensitive analytic ELISAs for subclass herpes virus IgG. , 1985, Journal of virological methods.

[14]  D. Stites,et al.  Comparison of six methods for the detection of antibody to cytomegalovirus , 1985, Journal of clinical microbiology.

[15]  C. Fraser,et al.  Specificity differentiation of herpes simplex virus types 1 and 2 by indirect immunofluorescence. , 1974, The Journal of infectious diseases.

[16]  D. Stites,et al.  Flow cytometric detection and quantitation of immune complexes using human C1q-coated microspheres. , 1986, Journal of immunological methods.

[17]  M. Wilson,et al.  A new microsphere-based immunofluorescence assay using flow cytometry. , 1988, Journal of immunological methods.