Optimal selection of PEMF signal for wound healing system

There have been few technical advances that add to wound healing in the past. It has been considered as a complicated issue to study as a result of its subjectivity, assorted qualities and complexity in the wound healing process and differing qualities of patients. The applications of PEMF (Pulsed Electromagnetic Field) radiations to the target tissue with the help of coil cause physiological changes at the cellular site and thereby facilitate the process of wound healing. In PEMF device the various combination of frequency, waveform and amplitude have different effects upon biological tissues. The efficacy of a PEMF device is highly dependent on waveforms that are used in combination with the pulsing frequencies. Therefore there is need of proper signal selection for generating PEMF. The current study has been conducted to show an optimization of signal based on frequency and duty cycle for magnetic stimulation. The work presented here consists of signal generator design and implementation of the design using hardware approach and simulation.

[1]  R. Balamurugan,et al.  Pulsed electromagnetic field (PEMF) treatment for fracture healing , 2009 .

[2]  D. Pienkowski,et al.  Comparison of asymmetrical and symmetrical pulse waveforms in electromagnetic stimulation , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  M A Stuchly,et al.  Cancer promotion in a mouse-skin model by a 60-Hz magnetic field: I. Experimental design and exposure system. , 1991, Bioelectromagnetics.

[4]  Arthur A. Pilla,et al.  Mechanisms and Therapeutic Applications of Time-Varying and Static Magnetic Fields , 2018, Biological and Medical Aspects of Electromagnetic Fields.

[5]  J. Moffett,et al.  Effect of pulsed electromagnetic field treatment on programmed resolution of inflammation pathway markers in human cells in culture , 2015, Journal of inflammation research.

[6]  A. Pilla ELECTROCHEMICAL INFORMATION TRANSFER AT LIVING CELL MEMBRANES , 1974, Annals of the New York Academy of Sciences.

[7]  R. Shahar,et al.  The effect of short, high intensity magnetic field pulses on the healing of skin wounds in rats , 2004, Bioelectromagnetics.

[8]  F. Barnes,et al.  Combined action of static and alternating magnetic fields on ionic current in aqueous glutamic acid solution. , 1998, Bioelectromagnetics.

[9]  K. Javed,et al.  Evaluation of bone fracture in animal model using bio-electrical impedance analysis , 2016 .

[10]  Janet Walker,et al.  Therapeutic Aspects of Electromagnetic Fields for Soft-Tissue Healing , 1995 .

[11]  A. Evangelou,et al.  The effect of pulsed electromagnetic fields on secondary skin wound healing: An experimental study , 2007, Bioelectromagnetics.

[12]  A. Yadollahpour,et al.  Therapeutic Applications of Electromagnetic Fields in Musculoskeletal Disorders: A Review of Current Techniques and Mechanisms of Action , 2014 .

[13]  R. Sherman,et al.  Treatment of Migraine With Pulsing Electromagnetic Fields: A Double‐Blind, Placebo‐Controlled Study , 1999, Headache.

[14]  T. K. Hunt,et al.  Human skin wounds: A major and snowballing threat to public health and the economy , 2009, Wound repair and regeneration : official publication of the Wound Healing Society [and] the European Tissue Repair Society.

[15]  W. Garner Pulsed Magnetic Fields Accelerate Cutaneous Wound Healing in Rats , 2009 .

[16]  Atit Tamtrakarn A Single-Battery Switching Boost Converting Pulse Generator for Functional Electrical Stimulation in Rehabilitation Application , 2014 .

[17]  An integrated ELF magnetic-field generator and incubator for long-term in vitro studies. , 1992, Bioelectromagnetics.