Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy

The value of capnography during procedural sedation and analgesia (PSA) for the detection of hypoxaemia during upper gastrointestinal (UGI) endoscopic procedures is limited. Photoplethysmography respiratory rate (RRp) monitoring may provide a useful alternative, but the level of agreement with capnography during PSA is unknown. We therefore investigated the level of agreement between the RRp and capnography-based RR (RRc) during PSA for UGI endoscopy. This study included patients undergoing PSA for UGI endoscopy procedures. Pulse oximetry (SpO2) and RRc were recorded in combination with Nellcor 2.0 (RRp) monitoring (Covidien, USA). Bland–Altman analysis was used to evaluate the level of agreement between RRc and RRp. Episodes of apnoea, defined as no detection of exhaled CO2 for minimal 36 s, and hypoxaemia, defined as an SpO2 < 92 %, were registered. A total of 1054 min of data from 26 patients were analysed. Bland–Altman analysis between the RRc and RRp revealed a bias of 2.25 ± 5.41 breath rate per minute (brpm), with limits of agreement from −8.35 to 12.84 brpm for an RR ≥ 4 brpm. A total of 67 apnoea events were detected. In 21 % of all apnoea events, the patient became hypoxaemic. Hypoxaemia occurred 42 times with a median length of 34 (19–141) s, and was preceded in 34 % of the cases by apnoea and in 64 % by an RRc ≥ 8 brpm. In 81 % of all apnoea events, photoplethysmography registered an RRp ≥ 4 brpm. We found a low level of agreement between capnography and the plethysmography respiratory rate during procedural sedation for UGI endoscopy. Moreover, respiratory rate derived from both the capnogram and photoplethysmogram showed a limited ability to provide warning signs for a hypoxaemic event during the sedation procedure.

[1]  J. Atkins,et al.  Performance of Masimo Rainbow Acoustic Monitoring for Tracking Changing Respiratory Rates Under Laryngeal Mask Airway General Anesthesia for Surgical Procedures in the Operating Room: A Prospective Observational Study , 2014, Anesthesia and analgesia.

[2]  C. Kalkman,et al.  Capnography During Deep Sedation with Propofol by Nonanesthesiologists: A Randomized Controlled Trial , 2014, Anesthesia and analgesia.

[3]  R. Marcus,et al.  The relationship between the Bispectral Index (BIS) and the Observer Alertness of Sedation Scale (OASS) scores during propofol sedation with and without ketamine: a randomized, double blinded, placebo controlled clinical trial , 2016, Journal of Clinical Monitoring and Computing.

[4]  J. Miner,et al.  End-tidal carbon dioxide monitoring during procedural sedation. , 2002, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[5]  J. N. Watson,et al.  Pulse oximetry-derived respiratory rate in general care floor patients , 2014, Journal of Clinical Monitoring and Computing.

[6]  R. Chuttani,et al.  A prospective assessment of sedation-related adverse events and patient and endoscopist satisfaction in ERCP with anesthesiologist-administered sedation. , 2011, Gastrointestinal endoscopy.

[7]  J. A. Blom,et al.  Peak-to-peak detector for the arterial pulsations in the plethysmogram II: Results of its use during anaesthesia , 1981, Medical and Biological Engineering and Computing.

[8]  D. Early,et al.  Obesity as a risk factor for sedation-related complications during propofol-mediated sedation for advanced endoscopic procedures. , 2011, Gastrointestinal endoscopy.

[9]  J. Burton,et al.  Does end-tidal carbon dioxide monitoring detect respiratory events prior to current sedation monitoring practices? , 2006, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[10]  J. Waugh,et al.  Capnography enhances surveillance of respiratory events during procedural sedation: a meta-analysis. , 2011, Journal of clinical anesthesia.

[11]  Welcome Guimera,et al.  Practice Guidelines for Sedation and Analgesia by Non- Anesthesiologists , 2005 .

[12]  L. Nilsson,et al.  Combined photoplethysmographic monitoring of respiration rate and pulse: a comparison between different measurement sites in spontaneously breathing subjects , 2007, Acta anaesthesiologica Scandinavica.

[13]  D. Early,et al.  Incidence of sedation-related complications with propofol use during advanced endoscopic procedures. , 2010, Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association.

[14]  Bhavani Shankar Kodali,et al.  Capnography outside the operating rooms. , 2013, Anesthesiology.

[15]  Gregory Zuccaro,et al.  Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy. , 2002, Gastrointestinal endoscopy.

[16]  T. Ebert,et al.  Ventilation monitoring during moderate sedation in GI patients , 2017, Journal of Clinical Monitoring and Computing.

[17]  M. Qadeer,et al.  Hypoxemia during Moderate Sedation for Gastrointestinal Endoscopy: Causes and Associations , 2011, Digestion.

[18]  E. Kochs,et al.  Capnography improves detection of apnea during procedural sedation for percutaneous transhepatic cholangiodrainage. , 2013, Canadian journal of gastroenterology = Journal canadien de gastroenterologie.

[19]  C. Beglinger,et al.  Safety of propofol for conscious sedation during endoscopic procedures in high-risk patients–a prospective, controlled study , 2003, American Journal of Gastroenterology.

[20]  L. Tarassenko,et al.  Photoplethysmographic derivation of respiratory rate: a review of relevant physiology , 2012, Journal of medical engineering & technology.

[21]  L. Nilsson Respiration Signals from Photoplethysmography , 2013, Anesthesia and analgesia.

[22]  A. Dahan,et al.  High-inspired oxygen concentration further impairs opioid-induced respiratory depression. , 2013, British journal of anaesthesia.

[23]  Baruch Krauss,et al.  Capnography for procedural sedation and analgesia in the emergency department. , 2007, Annals of emergency medicine.

[24]  D. Mathews,et al.  Monitoring minute ventilation versus respiratory rate to measure the adequacy of ventilation in patients undergoing upper endoscopic procedures , 2016, Journal of Clinical Monitoring and Computing.

[25]  A. Sinha,et al.  Outpatient endoscopic retrograde cholangiopancreatography: Safety and efficacy of anesthetic management with a natural airway in 653 consecutive procedures , 2013, Saudi journal of anaesthesia.

[26]  Knut Arvid Kirkebøen,et al.  Respiratory variations in the photoplethysmographic waveform amplitude depend on type of pulse oximetry device , 2016, Journal of Clinical Monitoring and Computing.

[27]  J. N. Watson,et al.  Developing an algorithm for pulse oximetry derived respiratory rate (RRoxi): a healthy volunteer study , 2012, Journal of Clinical Monitoring and Computing.

[28]  T. Stevens,et al.  Capnographic monitoring of respiratory activity improves safety of sedation for endoscopic cholangiopancreatography and ultrasonography. , 2009, Gastroenterology.

[29]  A. Pedotti,et al.  Effects of propofol anaesthesia on thoraco‐abdominal volume variations during spontaneous breathing and mechanical ventilation , 2011, Acta anaesthesiologica Scandinavica.

[30]  J. Miner,et al.  Does end tidal CO2 monitoring during emergency department procedural sedation and analgesia with propofol decrease the incidence of hypoxic events? A randomized, controlled trial. , 2010, Annals of emergency medicine.

[31]  Robert A. Smith,et al.  Supplemental oxygen impairs detection of hypoventilation by pulse oximetry. , 2004, Chest.