Integration of a handheld based anaesthesia rounding system into an anaesthesia information management system

BACKGROUND At the University Hospital Giessen, an anesthesia information management system (AIMS) is used for online record keeping of perioperative patient care, but preoperative anaesthesia assessments were still being recorded on paper and subsequently entered into the AIMS. Personal digital assistants (PDAs) seem to be useful instruments to establish a seamless digital anesthesiological documentation. OBJECTIVES We decided to implement a solution for direct integration of data gathered during the preoperative assessment into the existing data management infrastructure. Parallel to the development of the system, we surveyed the future users to match their wishes and needs as far as possible. SYSTEM DESCRIPTION A C program embedding the preoperative AIMS' data fields was developed. Data alignment with the Hospital information system (HIS) is controlled by a Java desktop software. The anaesthesiologist completes the available fields at the patient's bedside following the same algorithm and integrity check as the PC version. STATUS REPORT: Overall, 68% of the surveyed physicians supported the implementation of the system. The PDA solution has been available since May 2002. Data replication into the handheld and integration of mobile collected data into the AIMS generally work without problems. The HIS interconnection software converts the PDA file into the AIMS format for further processing. DISCUSSION The preoperative anaesthetic assessment is a standardised task well suitable for conversion to an electronic data storage medium. Changing from redundant data entry in the OR to direct electronic recording at the patient's bedside seems simply logical. Handheld computers are inexpensive, flexible gadgets to realize this.

[1]  Yuan-Hsiang Lin,et al.  A wireless PDA-based physiological monitoring system for patient transport , 2004, IEEE Transactions on Information Technology in Biomedicine.

[2]  E J Hammond,et al.  Electronic data collection by trainee anaesthetists using palm top computers. , 2000, European journal of anaesthesiology.

[3]  Orin M. Goldblum Electronic Prescribing: Criteria for Evaluating Hand-held Prescribing Systems and an Evaluation of a New, Hand-held, Wireless Wide Area Network (WWAN) Prescribing System , 2001, AMIA.

[4]  Marcela D. Rodríguez,et al.  Location-aware access to hospital information and services , 2004, IEEE Transactions on Information Technology in Biomedicine.

[5]  G. Hempelmann,et al.  Factors determining length of stay of surgical day-case patients. , 2001, European journal of anaesthesiology.

[6]  David W. Bates,et al.  Research Paper: Clinician Use of a Palmtop Drug Reference Guide , 2002, J. Am. Medical Informatics Assoc..

[7]  Axel Junger,et al.  Using an Anesthesia Information Management System to Prove a Deficit in Voluntary Reporting of Adverse Events in a Quality Assurance Program , 2004, Journal of Clinical Monitoring and Computing.

[8]  M Benson,et al.  Data processing at the anesthesia workstation: from data entry to data presentation. , 2000, Methods of information in medicine.

[9]  Computerized recordkeeping and information management in cardiothoracic and vascular anesthesia. , 1997, Journal of cardiothoracic and vascular anesthesia.

[10]  Qiang Fu,et al.  Anaesthesia record system on handheld computers - pilot experience and uses for quality control and clinical guidelines , 2005, Comput. Methods Programs Biomed..

[11]  M P Smith,et al.  The anesthesiologist's guide to Palm Computing. , 1999, Regional anesthesia and pain medicine.

[12]  Smith Nt,et al.  The anesthesia database, the automated record, and the quality assurance process. , 1992 .

[13]  Lewis Tj Integrating handheld PCs into a PACS network with commercially available components. , 2002 .

[14]  B. Sloan,et al.  Computerized patient anesthesia records: less time and better quality than manually produced anesthesia records. , 1993, Journal of clinical anesthesia.

[15]  G. Hempelmann,et al.  Incidence and risk calculation of inotropic support in patients undergoing cardiac surgery with cardiopulmonary bypass using an automated anaesthesia record-keeping system. , 2002, British journal of anaesthesia.

[16]  Axel Junger,et al.  The Incidence and Risk Factors for Hypotension After Spinal Anesthesia Induction: An Analysis with Automated Data Collection , 2002 .

[17]  S. Lapinsky,et al.  Handheld computers in critical care , 2001, Critical care.

[18]  Carsten Fuchs,et al.  Clinical and practical requirements of online software for anesthesia documentation - an experience report , 2000, Int. J. Medical Informatics.

[19]  John S McDonald,et al.  Anesthesiology Point of Care project. , 2002, Studies in health technology and informatics.

[20]  Abel,et al.  Eight year’s experience with automated anesthesia record keeping: Lessons learned—new directions taken , 1992, International journal of clinical monitoring and computing.

[21]  Qiang Fu,et al.  Using Mobile Information Technology to Build a Database For Anesthesia Quality Control and to Provide Clinical Guidelines , 2003, MIE.

[22]  N. T. Smith,et al.  The Anesthesia Database, the Automated Record, and the Quality Assurance Process , 1992, International anesthesiology clinics.

[23]  R. Gardner,et al.  Integrating computerized anesthesia charting into a hospital information system , 1995, International journal of clinical monitoring and computing.

[24]  Sangeeta Mehta,et al.  Prospective evaluation of an internet-linked handheld computer critical care knowledge access system , 2004, Critical care.