Reliability analysis of shutdown system

Abstract This paper presents the results of reliability analysis of Shutdown System (SDS) of Indian Prototype Fast Breeder Reactor. Reliability analysis carried out using Fault Tree Analysis predicts a value of 3.5 × 10−8/de for failure of shutdown function in case of global faults and 4.4 × 10−8/de for local faults. Based on 20 de/y, the frequency of shutdown function failure is 0.7 × 10−6/ry, which meets the reliability target, set by the Indian Atomic Energy Regulatory Board. The reliability is limited by Common Cause Failure (CCF) of actuation part of SDS and to a lesser extent CCF of electronic components. The failure frequency of individual systems is