Simultaneous MRI and PET imaging of a rat brain.

Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging.

[1]  Paul Marsden,et al.  A system to obtain radiotracer uptake data simultaneously with NMR spectra in a high field magnet , 1995 .

[2]  Raymond R Raylman,et al.  Positron emission mammography with tomographic acquisition using dual planar detectors: initial evaluations. , 2004, Physics in medicine and biology.

[3]  Chin-Tu Chen,et al.  Incorporation of correlated structural images in PET image reconstruction , 1994, IEEE Trans. Medical Imaging.

[4]  J.A. Fessler,et al.  Regularized emission image reconstruction using imperfect side information , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[5]  Richard M. Leahy,et al.  Incorporation of Anatomical MR Data for Improved Dunctional Imaging with PET , 1991, IPMI.

[6]  S. Majewski,et al.  Readout electronics for multianode photomultiplier tubes with pad matrix anode layout , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[7]  Alfred O. Hero,et al.  Model-based estimation with boundary side information or boundary regularization [cardiac emission CT] , 1994, IEEE Trans. Medical Imaging.

[8]  Anand Rangarajan,et al.  Bayesian reconstruction of functional images using anatomical information as priors , 1993, IEEE Trans. Medical Imaging.

[9]  Ciprian Catana,et al.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  P. Halsted,et al.  Design and development of an MR-compatible PET scanner for imaging small animals , 2004, IEEE Transactions on Nuclear Science.

[11]  Simon R. Cherry,et al.  Design of a small animal MR compatible PET scanner , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[12]  P. Vaska,et al.  Development of a simultaneous PET/MRI scanner , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[13]  Manuel Desco,et al.  PET, CT, and MR image registration of the rat brain and skull , 2001 .

[14]  J. Boone,et al.  Small-animal X-ray dose from micro-CT. , 2004, Molecular imaging.

[15]  Randy Wojcik,et al.  Initial tests of a prototype MRI-compatible PET imager , 2006 .

[16]  M. Schwaiger,et al.  Performance test of a LSO-APD PET module in a 9.4 Tesla magnet , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[17]  K Fetterly,et al.  Positron emission tomography within a magnetic field using photomultiplier tubes and lightguides. , 1995, Physics in medicine and biology.

[18]  P. Marsden,et al.  Gamma shielding materials for MR-compatible PET , 2003 .

[19]  R. Lecomte,et al.  A novel APD-based detector module for multi-modality PET/SPECT/CT scanners , 1998 .