Regularization Analysis and Design for Prior-Image-Based X-Ray CT Reconstruction

Prior-image-based reconstruction (PIBR) methods have demonstrated great potential for radiation dose reduction in computed tomography applications. PIBR methods take advantage of shared anatomical information between sequential scans by incorporating a patient-specific prior image into the reconstruction objective function, often as a form of regularization. However, one major challenge with PIBR methods is how to optimally determine the prior image regularization strength which balances anatomical information from the prior image with data fitting to the current measurements. Too little prior information yields limited improvements over traditional model-based iterative reconstruction, while too much prior information can force anatomical features from the prior image not supported by the measurement data, concealing true anatomical changes. In this paper, we develop quantitative measures of the bias associated with PIBR. This bias exhibits as a fractional reconstructed contrast of the difference between the prior image and current anatomy, which is quite different from traditional reconstruction biases that are typically quantified in terms of spatial resolution or artifacts. We have derived an analytical relationship between the PIBR bias and prior image regularization strength and illustrated how this relationship can be used as a predictive tool to prospectively determine prior image regularization strength to admit specific kinds of anatomical change in the reconstruction. Because bias is dependent on local statistics, we further generalized shift-variant prior image penalties that permit uniform (shift invariant) admission of anatomical changes across the imaging field of view. We validated the mathematical framework in phantom studies and compared bias predictions with estimates based on brute force exhaustive evaluation using numerous iterative reconstructions across regularization values. The experimental results demonstrate that the proposed analytical approach can predict the bias-regularization relationship accurately, allowing for prospective determination of the prior image regularization strength in PIBR. Thus, the proposed approach provides an important tool for controlling image quality of PIBR methods in a reliable, robust, and efficient fashion.

[1]  M. L. R. D. Christenson,et al.  Guidelines for Management of Small Pulmonary Nodules Detected on CT Scans: A Statement From the Fleischner Society , 2006 .

[2]  Jeffrey H Siewerdsen,et al.  Prospective regularization design in prior-image-based reconstruction , 2015, Physics in medicine and biology.

[3]  Jie Tang,et al.  Low radiation dose C-arm cone-beam CT based on prior image constrained compressed sensing (PICCS): including compensation for image volume mismatch between multiple data acquisitions , 2009, Medical Imaging.

[4]  Lei Xing,et al.  Improved compressed sensing-based cone-beam CT reconstruction using adaptive prior image constraints , 2012, Physics in medicine and biology.

[5]  J H Siewerdsen,et al.  dPIRPLE: a joint estimation framework for deformable registration and penalized-likelihood CT image reconstruction using prior images , 2014, Physics in medicine and biology.

[6]  J. Webster Stayman,et al.  Prospective Regularization Analysis and Design for Prior-Image-Based Reconstruction of X-ray CT , 2017 .

[7]  Hao Zhang,et al.  Integration of prior CT into CBCT reconstruction for improved image quality via reconstruction of difference: first patient studies , 2017, Medical Imaging.

[8]  Ella A Kazerooni,et al.  The solitary pulmonary nodule. , 2003, Chest.

[9]  J. Fessler,et al.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs , 1996, 5th IEEE EMBS International Summer School on Biomedical Imaging, 2002..

[10]  R. Stevens,et al.  Evaluation of the reconstruction-of-difference (RoD) algorithm for cone-beam CT neuro-angiography , 2018, Medical Imaging.

[11]  Jeffrey H Siewerdsen,et al.  PIRPLE: a penalized-likelihood framework for incorporation of prior images in CT reconstruction , 2013, Physics in medicine and biology.

[12]  Varut Vardhanabhuti,et al.  Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms. , 2013, AJR. American journal of roentgenology.

[13]  Jeffrey A. Fessler,et al.  Regularization Designs for Uniform Spatial Resolution and Noise Properties in Statistical Image Reconstruction for 3-D X-ray CT , 2015, IEEE Transactions on Medical Imaging.

[14]  Thorsten Heußer,et al.  Prior-based artifact correction (PBAC) in computed tomography. , 2014, Medical physics.

[15]  E. Hoffman,et al.  Ultra-low dose lung CT perfusion regularized by a previous scan. , 2009, Academic radiology.

[16]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[17]  Emil Y. Sidky,et al.  Prior-image-based few-view cone beam CT for applications to daily scan in image-guided radiation therapy: preliminary study , 2009, Medical Imaging.

[18]  Jean-Baptiste Thibault,et al.  A three-dimensional statistical approach to improved image quality for multislice helical CT. , 2007, Medical physics.

[19]  Lei Zhang,et al.  Low-Dose X-ray CT Reconstruction via Dictionary Learning , 2012, IEEE Transactions on Medical Imaging.

[20]  Jianhua Ma,et al.  Extracting Information From Previous Full-Dose CT Scan for Knowledge-Based Bayesian Reconstruction of Current Low-Dose CT Images , 2016, IEEE Transactions on Medical Imaging.

[21]  S. Swensen,et al.  Lung cancer screening with CT: Mayo Clinic experience. , 2003, Radiology.

[22]  Jing Huang,et al.  Iterative Reconstruction for X-Ray Computed Tomography Using Prior-Image Induced Nonlocal Regularization , 2014, IEEE Transactions on Biomedical Engineering.

[23]  Zhengrong Liang,et al.  Assessment of prior image induced nonlocal means regularization for low‐dose CT reconstruction: Change in anatomy , 2017, Medical physics.

[24]  Guang-Hong Chen,et al.  Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm , 2012, IEEE Transactions on Medical Imaging.

[25]  Ken D. Sauer,et al.  A local update strategy for iterative reconstruction from projections , 1993, IEEE Trans. Signal Process..

[26]  J. Webster Stayman,et al.  Evaluation of Low-Dose CT Perfusion for the Liver using Reconstruction of Difference , 2017 .

[27]  Jing Wang,et al.  Deriving adaptive MRF coefficients from previous normal-dose CT scan for low-dose image reconstruction via penalized weighted least-squares minimization. , 2014, Medical physics.

[28]  Hakan Erdogan,et al.  Ordered subsets algorithms for transmission tomography. , 1999, Physics in medicine and biology.

[29]  T Isomura,et al.  Lung cancer screening: minimum tube current required for helical CT. , 2000, Radiology.

[30]  Jeffrey H Siewerdsen,et al.  Information Propagation in Prior-Image-Based Reconstruction. , 2012, Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography.

[31]  J H Siewerdsen,et al.  Reconstruction of difference in sequential CT studies using penalized likelihood estimation , 2016, Physics in medicine and biology.

[32]  Meng Wu,et al.  Approximate path seeking for statistical iterative reconstruction , 2015, Medical Imaging.

[33]  Sana Boudabbous,et al.  Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations , 2013, European Radiology.