Modeling of the Plane Needle Cutting Edge Rake and Inclination Angles for Biopsy

Hollow needles are one of the most common medical devices, yet little study has focused on the needle tip cutting geometry for biopsy, which is a tissue cutting process. This research develops mathematical models to calculate the inclination and rake angles along cutting edges on needle tips generated by planes. Three types of plane needle tips, the one-plane bias bevel, multi-plane symmetrical, and two-plane nonsymmetric needles, are investigated. The models show that the leading tip of a bias bevel needle has an inclination angle of 0 deg, the worst configuration for cutting. Symmetric multiplane needles on the other hand have very high inclination angles, 60, 56.3, and 50.8 deg, given a needle formed by two-, three-, and four-plane, respectively, for a bevel angle of 30 deg and can assist more effective needle biopsy. The rake angle is at its greatest value (the best configuration for cutting), which equals the 90 deg minus the bevel angle, at the initial cutting point for the bias bevel needle. Experiments are performed using three 11 gauge two-plane symmetric needles with 20, 25, and 30 deg bevel angles on bovine liver and demonstrate that the needle tip geometry affects biopsy performance, where longer biopsy samples are collected with needles of higher rake and inclination angle.

[1]  Allison M. Okamura,et al.  Modeling of Tool-Tissue Interactions for Computer-Based Surgical Simulation: A Literature Review , 2008, PRESENCE: Teleoperators and Virtual Environments.

[2]  Kyle B. Reed,et al.  Mechanics of Flexible Needles Robotically Steered through Soft Tissue , 2010, Int. J. Robotics Res..

[3]  G. Hutarew,et al.  Prostate Biopsy Outcome Using 29 mm Cutting Length , 2005, Urologia Internationalis.

[4]  Jason Zachary Moore,et al.  BLADE OBLIQUE CUTTING OF TISSUE FOR INVESTIGATION OF BIOPSY NEEDLE INSERTION , 2009 .

[5]  C. Corbishley,et al.  Improving glandular coverage during prostate biopsy using a long‐core needle: technical performance of an end‐cutting needle , 2002, BJU international.

[6]  Rishi Singal,et al.  Fundamentals of Machining and Machine Tools , 2008 .

[7]  Allison M. Okamura,et al.  Robotic needle insertion: effects of friction and needle geometry , 2003, 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422).

[8]  A. Billis Needle core length in sextant biopsy influences prostate cancer detection rate. , 2002, International braz j urol : official journal of the Brazilian Society of Urology.

[9]  Rajni V. Patel,et al.  Needle insertion into soft tissue: a survey. , 2007, Medical engineering & physics.

[10]  Jin Seob Kim,et al.  Nonholonomic Modeling of Needle Steering , 2006, Int. J. Robotics Res..

[11]  Daniel Glozman,et al.  Flexible Needle Steering and Optimal Trajectory Planning for Percutaneous Therapies , 2004, MICCAI.

[12]  John S. Agapiou,et al.  Metal Cutting Theory and Practice , 1996 .

[13]  Allison M. Okamura,et al.  Modeling the Forces of Cutting With Scissors , 2008, IEEE Transactions on Biomedical Engineering.

[14]  Allison M. Okamura,et al.  Force modeling for needle insertion into soft tissue , 2004, IEEE Transactions on Biomedical Engineering.

[15]  T. Podder,et al.  EFFECTS OF TIP GEOMETRY OF SURGICAL NEEDLES: AN ASSESSMENT OF FORCE AND DEFLECTION , 2005 .