Noise Robust Mojette Reconstructions for Missing Wedge Effect Attenuation

The Mojette transform is a tomographic reconstruction method based on a discrete and finite interpretation of the Radon theorem. Since the Mojette acquisition follows the discrete image geometry, this method resolves the well-known irregular sampling problem. A specific algorithm called Corner Based Inversion (CBI) is proposed to reconstruct without any error an image from its projections even if the angular coverage is not sufficient (missing wedge). However, this reconstruction is noise sensitive and reconstruction from corrupted data fails. In this paper, we develop new noise robust CBI algorithms and we apply them both on discrete Mojette acquisitions and on usual Radon acquisitions. Reconstruction results are discussed to highlight the efficiency of these algorithms for usual tomography and perspectives are proposed to reduce the missing wedge effect.

[1]  Jean-Pierre V. Guédon,et al.  Spline Mojette transform. Applications in tomography and communications , 2002, 2002 11th European Signal Processing Conference.

[2]  Jean-Pierre V. Guédon,et al.  The Mojette Transform: The First Ten Years , 2005, DGCI.

[3]  Pascal Desbarats,et al.  Radon and Mojette Projections' Equivalence for Tomographic Reconstruction using Linear Systems , 2008 .

[4]  Akram Aldroubi,et al.  B-spline signal processing. II. Efficiency design and applications , 1993, IEEE Trans. Signal Process..

[5]  P. Midgley,et al.  Reducing the missing wedge: High-resolution dual axis tomography of inorganic materials. , 2006, Ultramicroscopy.

[6]  C.A. Bouman,et al.  Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithms for the IndyPET scanner , 2003, IEEE Transactions on Medical Imaging.

[7]  B. F. Logan,et al.  The Fourier reconstruction of a head section , 1974 .

[8]  Richard Gordon,et al.  Questions of uniqueness and resolution in reconstruction from projection , 1978 .

[9]  H Guan,et al.  Computed tomography using algebraic reconstruction techniques (ARTs) with different projection access schemes: a comparison study under practical situations , 1996, Physics in medicine and biology.

[10]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[11]  Ming Jiang,et al.  Convergence of the simultaneous algebraic reconstruction technique (SART) , 2003, Conference Record of Thirty-Fifth Asilomar Conference on Signals, Systems and Computers (Cat.No.01CH37256).

[12]  Akram Aldroubi,et al.  B-SPLINE SIGNAL PROCESSING: PART I-THEORY , 1993 .

[13]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[14]  Linda Kaufman,et al.  Implementing and Accelerating the EM Algorithm for Positron Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[15]  Akram Aldroubi,et al.  B-SPLINE SIGNAL PROCESSING: PART II-EFFICIENT DESIGN AND APPLICATIONS , 1993 .

[16]  Pascal Desbarats,et al.  Mojette reconstruction from noisy projections , 2010, 2010 2nd International Conference on Image Processing Theory, Tools and Applications.

[17]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[18]  P. Toft The Radon Transform - Theory and Implementation , 1996 .

[19]  Jean-Pierre Guédon The Mojette Transform: Theory and Applications , 2009 .

[20]  Jean-Pierre V. Guédon,et al.  The Mojette transform: Discrete angles for tomography , 2005, Electron. Notes Discret. Math..

[21]  Michael Unser,et al.  B-spline signal processing. I. Theory , 1993, IEEE Trans. Signal Process..