Measurement of Gd‐DTPA dialysis clearance rates by using a look‐locker imaging technique

The exponential clearance rate constant, (k), and filtration fraction (FF) have been measured for dialysis of Gadoliniumdiethylenetriaminepentaacetic acid (Gd‐DTPA) (Magnevist, Berlex, Wayne, NJ) solutions by using a Look‐Locker imaging technique under conditions of flow. The measured values of k for the Baxter CA‐50, CA‐110, and CA‐210 filters were 0.0037 ± 0.0003, 0.0057 ± 0.0017, and 0.0092 ± 0.0018 min−1, respectively, for dialysis of 4.0 liters of aqueous Gd‐DTPA solutions. The measured values of FF for the Baxter CA‐110 and CA‐210 filters were 0.060 ± 0.013 and 0.089 ± 0.015, respectively, for dialysis of aqueous Gd‐DTPA at 350 ml/min. The k and FF measurements agree with values that use inversion recovery (IR) on static samples obtained by drawing aliquots of solution during the course of dialysis. This in vitro experiment suggests that accurate in vivo measurements of filtration fraction and glomerular filtration rate (GFR) may be possible.

[1]  G F Gates,et al.  Split Renal Function Testing Using Tc–99m DTPA: A Rapid Technique for Determining Differential Glomerular Filtration , 1983, Clinical nuclear medicine.

[2]  N. Schneiders Solutions of two paramagnetic ions for use in nuclear magnetic resonance phantoms. , 1988, Medical physics.

[3]  S. Maier,et al.  Renal artery velocity mapping with MR imaging , 1995, Journal of magnetic resonance imaging : JMRI.

[4]  M. Koopman,et al.  Creatinine clearance during cimetidine administration for measurement of glomerular filtration rate , 1992, The Lancet.

[5]  M. Walser,et al.  Radioisotopic measurement of glomerular filtration rate in severe chronic renal failure. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  D. Look,et al.  Time Saving in Measurement of NMR and EPR Relaxation Times , 1970 .

[7]  A. Crawley,et al.  A comparison of one‐shot and recovery methods in T1 imaging , 1988, Magnetic resonance in medicine.

[8]  M. Buonocore,et al.  Noninvasive measurement of renal hemodynamic functions using gadolinium enhanced magnetic resonance imaging , 1994, Investigative radiology.

[9]  M H Buonocore,et al.  Noninvasive measurement of renal hemodynamic functions using gadolinium enhanced magnetic resonance imaging. , 1994, Magnetic resonance in medicine.

[10]  R. Henkelman,et al.  Practical Implementation and Optimization of One‐shot T1 imaging , 1991, Magnetic resonance in medicine.

[11]  M. Walser,et al.  Prediction of glomerular filtration rate from serum creatinine concentration in advanced chronic renal failure. , 1993, Kidney international.

[12]  William H. Press,et al.  Numerical recipes , 1990 .

[13]  J. Becker Evaluation of renal function. , 1991, Radiology.