Spectral Response of THM Grown CdZnTe Crystals

The spectral response of several crystals grown by the Traveling Heater Method (THM) were investigated. An energy resolution of 0.98% for a Pseudo Frisch-Grid of 4 times 4 times 9 mm3 and 2.1% FWHM for a coplanar-grid of size 11 times 11 times 5 mm3 were measured using 137Cs-662 keV. In addition a 4% FWHM at 122 keV has also been measured on 20 times 20 X 5 mm3 monolithic pixellated devices. The material shows great potential toward producing large-volume detectors with spectral performance that meets the requirement for high-resolution gamma-ray spectroscopy.

[1]  T. Schlesinger,et al.  Material uniformity of CdZnTe grown by low-pressure bridgman , 2001 .

[2]  Arnold Burger,et al.  Development of large single crystal (3-inch ingot) CdZnTe for large-volume nuclear radiation detectors , 2003, SPIE Optics + Photonics.

[3]  P. A. Russo,et al.  Electrode design for coplanar-grid detectors , 1996 .

[4]  Robert Triboulet,et al.  Cdte and CdZnTe crystal growth by horizontal bridgman technique , 1990 .

[5]  J. F. Schetzina,et al.  Properties of CdZnTe crystals grown by a high pressure Bridgman method , 1992 .

[6]  W. E. Collins,et al.  Low‐temperature photoluminescence of detector grade Cd1−xZnxTe crystal treated by different chemical etchants , 1996 .

[7]  Zhong He,et al.  Experimental results from an Imarad 8×8 pixellated CZT detector , 2001 .

[8]  P. Luke Electrode configuration and energy resolution in gamma-ray detectors , 1996 .

[9]  Csaba Szeles,et al.  Current Issues of High-Pressure Bridgman Growth of Semi-Insulating CdZnTe , 1997 .

[10]  P. Luke Single-polarity charge sensing in ionization detectors using coplanar electrodes , 1994 .

[11]  Michael R. Pelling,et al.  CZT detectors with 3D readout for gamma-ray spectroscopy and imaging , 2003, SPIE Optics + Photonics.

[12]  P. Luke,et al.  Coplanar-grid CdZnTe detector with three-dimensional position sensitivity , 2000 .

[13]  W. E. Collins,et al.  Study of gamma-ray detector performance of Cd1-xZnxTe crystal treated by different etchants , 1996, Optics & Photonics.

[14]  J. F. Butler,et al.  CdTe low level gamma detectors based on a new crystal growth method , 1988 .

[15]  Tuviah E. Schlesinger,et al.  Cadmium zinc telluride and its use as a nuclear radiation detector material , 2001 .

[16]  R. Guillemaud,et al.  Performance and perspectives of a CdZnTe-based gamma camera for medical imaging , 2004, IEEE Transactions on Nuclear Science.

[17]  L. Verger,et al.  A capacitive Frisch grid structure for CdZnTe detectors , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[18]  P. K. Nag,et al.  Passivation of CdZnTe surfaces by oxidation in low energy atomic oxygen , 1999 .

[19]  W. E. Collins,et al.  Characterization of metal contacts on and surfaces of cadmium zinc telluride , 1999 .

[20]  P. Luke Unipolar charge sensing with coplanar electrodes-application to semiconductor detectors , 1995 .

[21]  Zhong He,et al.  Position-sensitive single carrier CdZnTe detectors , 1997 .

[22]  Feng Zhang,et al.  Analysis of detector response using 3-D position-sensitive CZT gamma-ray spectrometers , 2003, IEEE Transactions on Nuclear Science.

[23]  W. E. Collins,et al.  Investigation of electrical contacts for Cd/sub 1-x/Zn/sub x/Te nuclear radiation detector , 1997 .

[24]  S. V. Vadawale,et al.  Multipixel characterization of imaging CZT detectors for hard x-ray imaging and spectroscopy , 2004, SPIE Optics + Photonics.

[25]  D. Wehe,et al.  Single charge carrier type sensing with a parallel strip pseudo-Frisch-grid CdZnTe semiconductor radiation detector , 1998 .

[26]  R. Triboulet The Travelling Heater Method (THM) for Hg1−xCdxTe and related materials , 1994 .

[27]  R. James,et al.  Characterization of Traveling Heater Method (THM) Grown ${\hbox{Cd}}_{0.9}{\hbox{Zn}}_{0.1}{\hbox{Te}}$ Crystals , 2007, IEEE Transactions on Nuclear Science.

[28]  T. Schlesinger,et al.  Semiconductors for room temperature nuclear detector applications , 1995 .

[29]  M. Ohmori,et al.  High quality CdTe and its application to radiation detectors , 1993 .

[30]  Allon Shahar,et al.  CZT pixel detectors equipped with effective Ohmic contacts; their spectroscopic performance and the enigma of why they thus behave , 1999, Optics & Photonics.

[31]  C. Budtz-Jørgensen,et al.  CdZnTe drift detector with correction for hole trapping , 1998 .

[32]  P. Luke,et al.  A CdZnTe coplanar-grid detector array for environmental remediation , 2001 .