Polymer-Enhanced Capillary Transient Isotachophoresis with Boronic Acid-Functionalized Squarylium Dyes for the Fluorescent Determination of Digoxin and Digoxigenin

ABSTRACT Here is reported a new application of polymer-enhanced capillary transient isotachophoresis for the separation and quantification of the drug digoxin and its primary metabolite digoxigenin coupled with laser-induced fluorescence (LIF) detection facilitated by labeling with two boronic acid-functionalized squarylium dyes of different alkyl side chain lengths, SQ-BA1 and SQ-BA2. The conditions for drug–dye complex formation were optimized, as determined by absorbance and fluorescence spectra, according to solution pH and buffer composition. As digoxin has a digitoxose sugar moiety in its structure, it was shown to exhibit better enhancement in the fluorescence intensity of both dyes than digoxigenin, which lacks this moiety, presumably through the formation of a cyclic boronate ester complex. A comparison of analyte labeling in pre-column and on-column modes was conducted in subsequent capillary electrophoresis-LIF studies, with the latter labeling mode yielding superior sensitivity. However, to achieve the complete resolution of labeled digoxin and digoxigenin analytes, it was necessary to use the modified isotachophoresis method, with added borate ions that may differentially interact with the drug and its metabolite, hence affecting their mobilities. Limits of quantification of the method for the determination of digoxin with SQ-BA1 and SQ-BA2 were 2.61 × 10−3 and 2.82 × 10−3 M and limits of detection were 7.83 × 10−4 and 8.47 × 10−4 M while sensitivities were as great as 5.06 × 109 and 2.89 × 109 M−1, respectively, indicating that the method is suitable for practical analysis.

[1]  M. Shibukawa,et al.  Molecular design of boronic acid-functionalized squarylium cyanine dyes for multiple discriminant analysis of sialic acid in biological samples: selectivity toward monosaccharides controlled by different alkyl side chain lengths. , 2015, Analytical chemistry.

[2]  C. Colyer,et al.  An application of polymer-enhanced capillary transient isotachophoresis with an emissive boronic acid functionalized squarylium dye as an on-capillary labeling agent for gram-positive bacteria. , 2013, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[3]  M. Marina,et al.  Molecularly imprinted SPE and MEKC with in‐capillary sample preconcentration for the determination of digoxin in human urine , 2012, Electrophoresis.

[4]  Tara L. Massie,et al.  Asymmetric Mono- and Bis-Squarylium Dyes as Pre-Column and On-Column Labels for Protein Analysis by Capillary Electrophoresis with Laser-Induced Fluorescence Detection , 2012 .

[5]  Takeshi Maeda,et al.  A Long-Wavelength Fluorescent Squarylium Cyanine Dye Possessing Boronic Acid for Sensing Monosaccharides and Glycoproteins with High Enhancement in Aqueous Solution , 2012, Sensors.

[6]  Tara L. Massie,et al.  On-column labeling of gram-positive bacteria with a boronic acid functionalized squarylium cyanine dye for analysis by polymer-enhanced capillary transient isotachophoresis. , 2012, Analytical chemistry.

[7]  Rawi Ramautar,et al.  High capacity capillary electrophoresis-electrospray ionization mass spectrometry: coupling a porous sheathless interface with transient-isotachophoresis. , 2010, Analytical chemistry.

[8]  Gang-yi Liu,et al.  Therapeutic monitoring of serum digoxin for patients with heart failure using a rapid LC-MS/MS method. , 2010, Clinical biochemistry.

[9]  F. Borrull,et al.  Sorbent preconcentration procedures coupled to capillary electrophoresis for environmental and biological applications. , 2008, Analytica chimica acta.

[10]  A. Marino,et al.  Development of a quantitative LC-MS/MS analytical method coupled with turbulent flow chromatography for digoxin for the in vitro P-gp inhibition assay. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[11]  R. Moreno,et al.  Digoxin bioequivalence study: determination in human plasma by microparticle enzyme immunoassay. , 2007, International journal of clinical pharmacology and therapeutics.

[12]  Rajiv Bharadwaj,et al.  On-chip millionfold sample stacking using transient isotachophoresis. , 2006, Analytical chemistry.

[13]  Hsin-Lung Wu,et al.  Simultaneous determination of digoxin and digitoxin by micellar electrokinetic chromatography and application to drug formulations , 2003 .

[14]  A. Jedlička,et al.  HPLC method with UV detection for evaluation of digoxin tablet dissolution in acidic medium after solid-phase extraction. , 2003, Journal of pharmaceutical and biomedical analysis.

[15]  S. Chong,et al.  A rapid and sensitive LC/MS/MS assay for quantitative determination of digoxin in rat plasma. , 2003, Journal of pharmaceutical and biomedical analysis.

[16]  D. Armstrong,et al.  Monitoring the migration behavior of living microorganisms in capillary electrophoresis using laser‐induced fluorescence detection with a charge‐coupled device imaging system , 2002, Electrophoresis.

[17]  T. Araki,et al.  Development of radioimmunoassay for measurement of serum digoxin in digitalized patients using novel anti-digoxin antiserum. , 2002, Biological & pharmaceutical bulletin.

[18]  J. Sowell,et al.  Investigation of the spectral properties of a squarylium near-infrared dye and its complexation with Fe(III) and Co(II) ions. , 2000, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[19]  M. Breadmore,et al.  On-capillary ion-exchange preconcentration of inorganic anions in open-tubular capillary electrochromatogrpahy with elution using transient-isotachophoretic gradient. 2. Characterization of the isotachophoretic gradient. , 2001, Analytical chemistry.

[20]  D. Armstrong,et al.  Separating microbes in the manner of molecules. 1. Capillary electrokinetic approaches. , 1999, Analytical chemistry.

[21]  X. Le,et al.  Capillary electrophoretic immunoassays for digoxin and gentamicin with laser-induced fluorescence polarization detection. , 1999, Journal of chromatography. B, Biomedical sciences and applications.

[22]  B. Ludes,et al.  High-performance liquid chromatography-ionspray mass spectrometry for the specific determination of digoxin and some related cardiac glycosides in human plasma. , 1997, Journal of chromatography. B, Biomedical sciences and applications.

[23]  R. Sams,et al.  Specific and sensitive determination of digoxin and metabolites in human serum by high performance liquid chromatography with cyclodextrin solid-phase extraction and precolumn fluorescence derivatization. , 1995, Journal of pharmaceutical and biomedical analysis.

[24]  B. Kimball,et al.  Quantitation of digitoxin, digoxin, and their metabolites by high-performance liquid chromatography using pulsed amperometric detection , 1995 .

[25]  X. Liu,et al.  Capillary electrophoretic enzyme immunoassay for digoxin in human serum. , 1995, Analytical chemistry.

[26]  L. Winger,et al.  High-performance assays of small molecules: enhanced sensitivity, rapidity, and convenience demonstrated with a noncompetitive immunometric anti-immune complex assay system for digoxin. , 1994, Clinical chemistry.

[27]  W. Heineman,et al.  Electrochemical enzyme immunoassay using sequential saturation technique in a 20-μl capillary: digoxin as a model analyte , 1994 .

[28]  Barry L. Karger,et al.  On-column transient and coupled column isotachophoretic preconcentration of protein samples in capillary zone electrophoresis , 1992 .

[29]  William J. Jusko,et al.  Berichten , 2005, Pharmaceutisch weekblad.

[30]  H. Bessen Therapeutic and toxic effects of digitalis: William Withering, 1785. , 1986, The Journal of emergency medicine.

[31]  B. A. Bush,et al.  Effect of protein concentration on the determination of digoxin in serum by fluorescence polarization immunoassay. , 1984, Clinical chemistry.

[32]  H. Neu,et al.  Digoxin-inactivating bacteria: identification in human gut flora. , 1983, Science.

[33]  L. Longerich,et al.  Digoxigenin biotransformation , 1982, Clinical pharmacology and therapeutics.

[34]  R. Christenson,et al.  A routine method for the determination of digoxin in urine by radioimmunoassay. , 1982, Clinica chimica acta; international journal of clinical chemistry.

[35]  Marcus Fi,et al.  The reactivity of derivatives of digoxin and digitoxin as measured by the Na-K-atpase displacement assay and by radioimmunoassay. , 1975 .

[36]  J. Ryan,et al.  The reactivity of derivatives of digoxin and digitoxin as measured by the Na-K-atpase displacement assay and by radioimmunoassay. , 1975, The Journal of laboratory and clinical medicine.