This paper reports on indirect cooling of high-power IC chips of notebook computers using a two phase closed thermosyphon loop with Fluorinert (FC-72) as the working fluid. The experimental set-up consists of an evaporator and a condenser connected by flexible tubing. The evaporator corresponds to a high-power IC chip, and the condenser represents a cooling plate located behind the display of notebook computer. The evaporator and the condenser have the outer dimensions of 50mm x 50mm x 20mm and 150mm x 200mm x 20mm, respectively. The effects of the heat input Q and the charged volume of Fluorinert liquid F on the heat transfer characteristics of the cooling system were studied experimentally. Further, the experiment for the evaporator with plate fin to enhance the boiling in the evaporator was carried out. It has been confirmed that the heater surface temperature for the evaporator with plate fin reduces about 10% in comparison with those for the evaporator without fin. It is found that enhancing the boiling in the evaporator is very effective to reduce the surface temperature of heater. In the case of the evaporator with the plate fin, the temperature difference between the heater surface and ambient is kept around 60K for the highest heat input Q=30W in the present experiments.
[1]
H. Honda,et al.
Enhanced Boiling of FC-72 on Silicon Chips with Micro-Pin-Fins and Submicron-Scale Roughness
,
2002
.
[2]
S. Gima,et al.
H105 INDIRECT FLUORINERT COOLING OF NOTEBOOK COMPUTERS WITH HIGH-POWER IC CHIPS(Electronics cooling-1)
,
2000
.
[3]
T. Tomimura,et al.
Experimental study on liquid cooling of high-power IC chips
,
1999
.
[4]
Yogendra Joshi,et al.
Performance of a Compact Two-Chamber Two-Phase Thermosyphon : Effect of Evaporator Inclination , Liquid Fill Volume and Contact Resistance
,
1998
.
[5]
Hideaki Imura,et al.
Natural-convection heat transfer from a plate with arbitrary inclination
,
1972
.
[6]
Rahmatollah Khodabandeh,et al.
An Experimental Investigation of Critical Heat Flux (CHF) in a Vertical Narrow Channel in an Advanced Thermosyphon Loop
,
2001
.