Multi-transmit beam forming for fast cardiac imaging-a simulation study

Imaging at high temporal resolution is critical for a better understanding of transient cardiac phases with potential diagnostic value. Typically, parallel receive beam forming is used to achieve this. As an alternative, transmitting multiple lines simultaneously [i.e., multi-line transmit (MLT)] has been proposed. However, this approach has received less attention, most likely because of potential cross-talk artifacts between beams. In this study, based on different transducer configurations, the cross-talk level of different MLT systems was investigated and their point spread functions (PSFs) were compared with that of conventional beam forming (single-line transmit, SLT) by computer simulation. To reduce cross-talk artifacts, 7 different windowing functions were tested on transmit and receive: rectangular, Tukey (α = 0.5), Hann, cosine, Hamming, Gaussian (α = 0.4), and Nuttall. The simulation results showed the cross-talk varied inversely with the MLT beam opening angle and apodization could significantly reduce these artifacts at distinct opening angles, which were dependent on the transducer configuration. The optimal settings for an MLT system were highly dependent on the exact transducer configuration and must be deduced based on a given transducer. In particular, for a typical cardiac transducer configuration, a 4MLT imaging system with an opening angle of 22.73° and a Tukey (α = 0.5)-Tukey (α = 0.5) windowing scheme provided very similar image quality to SLT but with a 4 times higher frame rate. In addition, the MLT approach can be combined with (multiple) parallel receive beamforming to increase frame rate further. With these methods, a frame rate of approximately 300 Hz can be achieved to generate a 90° sector image without significant loss in image quality.

[1]  M. Fink,et al.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  K. Kristoffersen,et al.  Parallel beamforming using synthetic transmit beams , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Toshio Shirasaka Ultrasonic imaging apparatus using pulsed Doppler signal , 1989 .

[4]  Marc D Weinshenker,et al.  Explososcan: a parallel processing technique for high speed ultrasound imaging with linear phased arrays. , 1984 .

[5]  P. Stepanishen The Time‐Dependent Force and Radiation Impedance on a Piston in a Rigid Infinite Planar Baffle , 1971 .

[6]  Paul Suetens,et al.  The calculation of the transient near and far field of a baffled piston using low sampling frequencies , 1997 .

[7]  Matthias Bo Stuart,et al.  Performance of SARUS: A synthetic aperture real-time ultrasound system , 2010, 2010 IEEE International Ultrasonics Symposium.

[8]  Tore Gruner Bjastad,et al.  High frame rate ultrasound imaging using parallel beamforming , 2009 .

[9]  T. Misaridis,et al.  Use of modulated excitation signals in medical ultrasound. Part III: high frame rate imaging , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Jian-yu Lu,et al.  Extended high-frame rate imaging method with limited-diffraction beams , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. II. Parallel processing and image display , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  P. Stepanishen Transient Radiation from Pistons in an Infinite Planar Baffle , 1970 .

[13]  K. Thomenius,et al.  Accelerated focused ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Hiroshi Kanai,et al.  High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming , 2011, Journal of Medical Ultrasonics.

[15]  A. Drukarev,et al.  Beam transformation techinques for ultrasonic medical imaging , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  A. Dallai,et al.  ULA-OP: an advanced open platform for ultrasound research , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  Raoul Mallart,et al.  Improved imaging rate through simultaneous transmission of several ultrasound beams , 1992, SPIE Optics + Photonics.

[18]  Hon Fai Choi,et al.  Comparison of conventional parallel beamforming with plane wave and diverging wave imaging for cardiac applications: a simulation study , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.