Improved Flux-Weakening Control of IPMSMs Based on Torque Feedforward Technique

A flux-weakening control algorithm with an improved stator flux linkage command's adjustment part of interior permanent magnet synchronous motors is proposed in this paper. The current commands are derived from lookup tables, which consider variation of motor parameters. The merits of this algorithm are the maximization of torque and high torque stability. Experimental results are demonstrated to verify the effectiveness of the proposed algorithm.

[1]  Zhongping Yang,et al.  A novel flux-weakening control method based on single current regulator for permanent magnet synchronous motor , 2014, 2014 International Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE ASIA).

[2]  Seung-Ki Sul,et al.  Voltage Feedback Current Control Scheme for Improved Transient Performance of Permanent Magnet Synchronous Machine Drives , 2012, IEEE Transactions on Industrial Electronics.

[3]  Maarten J. Kamper,et al.  Optimal Torque Control of Synchronous Machines Based on Finite-Element Analysis , 2010, IEEE Transactions on Industrial Electronics.

[4]  Sung-Yoon Jung,et al.  Current Minimizing Torque Control of the IPMSM Using Ferrari’s Method , 2013, IEEE Transactions on Power Electronics.

[5]  Seung-Ki Sul,et al.  Field weakening control of interior permanent magnet machine using improved current interpolation technique , 2006 .

[6]  S.R. MacMinn,et al.  Control techniques for improved high-speed performance of interior PM synchronous motor drives , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[7]  Hideo Nakai,et al.  Development and testing of the torque control for the permanent-magnet synchronous motor , 2005, IEEE Transactions on Industrial Electronics.

[8]  Seung-Ki Sul,et al.  A novel flux weakening algorithm for surface mounted permanent magnet synchronous machines with infinite constant power speed ratio , 2007, 2007 International Conference on Electrical Machines and Systems (ICEMS).

[9]  Yazan M. Alsmadi,et al.  High fidelity nonlinear IPM modeling based on measured stator winding flux linkage , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[10]  Joachim Holtz,et al.  On continuous control of PWM inverters in the overmodulation range including the six-step mode , 1992, Proceedings of the 1992 International Conference on Industrial Electronics, Control, Instrumentation, and Automation.

[11]  Xuhui Wen,et al.  A new precise torque control method of PMSMs in flux-weakening operation , 2014, 2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific).

[12]  Jiunn-Jiang Chen,et al.  Minimum copper loss flux-weakening control of surface mounted permanent magnet synchronous motors , 2003 .

[13]  Yen-Shin Lai,et al.  Voltage Control Technique for the Extension of DC-Link Voltage Utilization of Finite-Speed SPMSM Drives , 2012, IEEE Transactions on Industrial Electronics.

[14]  Shigeo Morimoto,et al.  Wide-speed operation of interior permanent magnet synchronous motors with high-performance current regulator , 1994 .

[15]  D. Howe,et al.  Online optimal flux-weakening control of permanent-magnet brushless AC drives , 2000 .

[16]  M. Sanada,et al.  Effects and Compensation of Magnetic Saturation in Flux-Weakening Controlled Permanent Magnet Synchronous Motor Drives , 1994 .

[17]  Zhongping Yang,et al.  Flux-weakening control of PMSM based on single current regulator and variable q-axis voltage , 2012, 2012 15th International Conference on Electrical Machines and Systems (ICEMS).

[18]  Longya Xu,et al.  Characterizing the torque lookup table of an IPM machine for automotive application , 2014, 2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific).

[19]  M. Trlep,et al.  Evaluation of saturation and cross-magnetization effects in interior permanent magnet synchronous motor , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[20]  Gianmario Pellegrino,et al.  Performance Comparison Between Surface-Mounted and Interior PM Motor Drives for Electric Vehicle Application , 2012, IEEE Transactions on Industrial Electronics.

[21]  Chung-Yuen Won,et al.  IPMSM torque control method considering DC-link voltage variation and friction torque for EV/HEV applications , 2012, 2012 IEEE Vehicle Power and Propulsion Conference.

[22]  S. Sul,et al.  Novel Antiwindup of a Current Regulator of a Surface-Mounted Permanent-Magnet Motor for Flux-Weakening Control , 2005, IEEE Transactions on Industry Applications.

[23]  Bing Cheng,et al.  Torque Feedforward Control Technique for Permanent Magnet Synchronous Motors , 2007, IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society.

[24]  Seung-Ki Sul,et al.  Speed control of interior permanent magnet synchronous motor drive for the flux weakening operation , 1997 .

[25]  Thomas M. Jahns,et al.  Flux-Weakening Regime Operation of an Interior Permanent-Magnet Synchronous Motor Drive , 1987, IEEE Transactions on Industry Applications.

[26]  Dong-Choon Lee,et al.  A novel overmodulation technique for space vector PWM inverters , 1997, PESC97. Record 28th Annual IEEE Power Electronics Specialists Conference. Formerly Power Conditioning Specialists Conference 1970-71. Power Processing and Electronic Specialists Conference 1972.

[27]  Khoa Dang Hoang,et al.  Online Control of IPMSM Drives for Traction Applications Considering Machine Parameter and Inverter Nonlinearities , 2015, IEEE Transactions on Transportation Electrification.

[28]  Seung-Ki Sul,et al.  New field weakening technique for high saliency interior permanent magnet motor , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[29]  Seung-Ki Sul,et al.  Novel Flux-Weakening Control of an IPMSM for Quasi-Six-Step Operation , 2008, IEEE Transactions on Industry Applications.

[30]  Longya Xu,et al.  A new method to optimize q-axis voltage for deep flux weakening control of IPM machines based on single current regulator , 2008, 2008 International Conference on Electrical Machines and Systems.

[31]  D. P. Atherton,et al.  An analysis package comparing PID anti-windup strategies , 1995 .

[32]  Ali Emadi,et al.  Speed Range Extended Maximum Torque Per Ampere Control for PM Drives Considering Inverter and Motor Nonlinearities , 2017, IEEE Transactions on Power Electronics.

[33]  S. Morimoto,et al.  Expansion of operating limits for permanent magnet motor by current vector control considering inverter capacity , 1990 .