Revision of the acetabular component without cement after total hip arthroplasty. A concise follow-up, at fifteen to nineteen years, of a previous report.

We previously reported our results at a minimum of three and seven years after use of a porous-coated acetabular metal shell in a consecutive series of 138 revision total hip arthroplasties. The current report presents the longer-term outcomes of these procedures, at fifteen to nineteen years postoperatively. A total of twenty metal shells (14%) underwent repeat revision. Seven of the repeat revisions were performed because of recurrent dislocation, seven were done at the time of femoral revision surgery, and six were done because of infection. Nineteen of the revised shells were well fixed, and one was aseptically loose. Of the sixty-seven hips in which the acetabular component survived for more than fifteen years after the index operation, two (3%) required a change of the modular acetabular liner because of wear or osteolysis. Nine (16%) of the fifty-seven hips with at least fifteen years of radiographic follow-up had an osteolytic lesion of >1 cm in diameter. The fifteen-year survival rate of the metal shells, with failure defined as revision because of loosening or as radiographic evidence of loosening, was 97%. Revision total hip arthroplasty with this cementless acetabular component has been followed by excellent component survivorship at fifteen years; the most common reasons for repeat revision were recurrent dislocation and infection.

[1]  E. Kaplan,et al.  Nonparametric Estimation from Incomplete Observations , 1958 .

[2]  W. Harris,et al.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. , 1969, The Journal of bone and joint surgery. American volume.

[3]  J. Galante,et al.  Revision of the acetabular component without cement after total hip arthroplasty. Three to six-year follow-up. , 1993, The Journal of bone and joint surgery. American volume.

[4]  J O Galante,et al.  Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement. , 1993, The Journal of bone and joint surgery. American volume.

[5]  J. Lawrence,et al.  Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. , 1994, The Journal of arthroplasty.

[6]  J. Galante,et al.  Revision of the Acetabular Component without Cement after Total Hip Arthroplasty. A Follow-up Note Regarding Results at Seven to Eleven Years* , 1996, The Journal of bone and joint surgery. American volume.

[7]  J O Galante,et al.  Second-Generation Cementless Total Hip Arthroplasty: Eight to Eleven-Year Results , 2001, The Journal of bone and joint surgery. American volume.

[8]  H. Amstutz,et al.  Fate of cementless acetabular components retained during revision total hip arthroplasty. , 2003, The Journal of bone and joint surgery. American volume.