Radial Mass Sensitivity of the Quartz Crystal Microbalance in Liquid Media

[1]  G. Sauerbrey Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung , 1959 .

[2]  G. Sauerbrey,et al.  Use of quartz vibration for weighing thin films on a microbalance , 1959 .

[3]  Chih‐shun Lu,et al.  Investigation of film‐thickness determination by oscillating quartz resonators with large mass load , 1972 .

[4]  J. Najarian,et al.  An immunospecific microbalance. , 1972, Journal of biomedical materials research.

[5]  G. Guilbault Uses of the Piezoelectric Crystal Detector in Analytical Chemistry , 1981 .

[6]  M. Albrecht,et al.  Effects of stressed materials on the radial sensitivity function of a quartz crystal microbalance , 1982 .

[7]  J. Roederer,et al.  Microgravimetric immunoassay with piezoelectric crystals , 1983 .

[8]  K. Kanazawa,et al.  Gravimetric Electrochemical Voltage Spectroscopy: In Situ Mass Measurements during Electrochemical Doping of the Conducting Polymer Polypyrrole , 1984 .

[9]  J. Gordon,et al.  Frequency of a quartz microbalance in contact with liquid , 1985 .

[10]  K. Kanazawa,et al.  The quartz microbalance: A sensitive tool to probe surface reconstructions on gold electrodes in liquid , 1985 .

[11]  Stanley Bruckenstein,et al.  Experimental aspects of use of the quartz crystal microbalance in solution , 1985 .

[12]  J. Gordon,et al.  Direct determination of the mass of an underpotentially deposited monolayer of lead on gold , 1986 .

[13]  George G. Guilbault,et al.  Parathion antibodies on piezoelectric crystals , 1986 .

[14]  H. Masuda,et al.  Study of Electrochromic Reactions of WO3/H+ System by In Situ Electrogravimetry , 1987 .

[15]  J. Gordon,et al.  Observation of morphological relaxation of copper and silver electrodes in solution using a quartz microbalance , 1987 .

[16]  W. Stöckel,et al.  An in situ study on the mechanism of the electrochemical dissolution of copper in oxygenated sulphuric acid: An application on the quartz microbalance , 1987 .

[17]  E Tamiya,et al.  Piezoelectric crystal biosensor modified with protein A for determination of immunoglobulins. , 1987, Analytical chemistry.

[18]  D. Buttry,et al.  Applications of the quartz crystal microbalance to electrochemistry. Measurement of ion and solvent populations in thin films of poly(vinylferrocene) as functions of redox state , 1989 .

[19]  D. Buttry,et al.  Determination of ion populations and solvent content as functions of redox state and pH in polyaniline , 1987 .

[20]  J. Reynolds,et al.  A quartz microbalance study of the electrosynthesis of polypyrrole , 1988 .

[21]  Michael D. Ward,et al.  Amplified mass immunosorbent assay with a quartz crystal microbalance , 1988 .

[22]  M. Ward Ion exchange of ferro(ferri)cyanide in polyvinylferrocene films , 1988 .

[23]  M. Ward Investigation of open circuit reactions of polymer films using the quartz crystal microbalance. Reactions of polyvinylferrocene films , 1988 .

[24]  O. Melroy,et al.  Underpotential metal deposition on gold, monitored in situ with a quartz microbalance , 1988 .

[25]  Harold E. Hager,et al.  Velocity profile on quartz crystals oscillating in liquids , 1989 .

[26]  Michael D. Ward,et al.  Spontaneously Formed Functionally Active Avidin Monolayers on Metal Surfaces: A Strategy for Immobilizing Biological Reagents and Design of Piezoelectric Biosensors , 1990 .

[27]  M. Ward,et al.  In Situ Interfacial Mass Detection with Piezoelectric Transducers , 1990, Science.