In vivo cellular-resolution retinal imaging in infants and children using an ultracompact handheld probe

A handheld probe enables retinal imaging in children. Enabled by adaptive optics, retinal photoreceptor cell imaging is changing our understanding of retinal structure1,2 and function3,4, as well as the pathogenesis of numerous ocular diseases5. To date, use of this technology has been limited to cooperative adult subjects due to the size, weight and inconvenience of the equipment, thus excluding study of retinal maturation during human development. Here, we report the design and operation of a handheld probe that can perform both scanning laser ophthalmoscopy and optical coherence tomography of the parafoveal photoreceptor structure in infants and children without the need for adaptive optics. The probe, featuring a compact optical design weighing only 94 g, was able to quantify packing densities of parafoveal cone photoreceptors and visualize cross-sectional photoreceptor substructure in children with ages ranging from 14 months to 12 years. The probe will benefit paediatric research by improving the understanding of retinal development, maldevelopment and early onset of disease during human growth.

[1]  David A Atchison,et al.  Eye shape in emmetropia and myopia. , 2004, Investigative ophthalmology & visual science.

[2]  David Williams,et al.  Optical fiber properties of individual human cones. , 2002, Journal of vision.

[3]  Joseph A. Izatt,et al.  True color scanning laser ophthalmoscopy and optical coherence tomography handheld probe. , 2014, Biomedical optics express.

[4]  Austin Roorda,et al.  High-speed, image-based eye tracking with a scanning laser ophthalmoscope , 2012, Biomedical optics express.

[5]  J. Duker,et al.  Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second. , 2010, Optics express.

[6]  David Williams,et al.  Noninvasive imaging of the human rod photoreceptor mosaic using a confocal adaptive optics scanning ophthalmoscope , 2011, Biomedical optics express.

[7]  Nicolas Chateau,et al.  Biomedical imaging: New view of the eye , 2011 .

[8]  Sina Farsiu,et al.  Optimization of confocal scanning laser ophthalmoscope design , 2013, Journal of biomedical optics.

[9]  Lawrence C. Sincich,et al.  Resolving Single Cone Inputs to Visual Receptive Fields , 2009, Nature Neuroscience.

[10]  Joseph A. Izatt,et al.  Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation , 2010, Optics express.

[11]  Christoph Kolbitsch,et al.  Ultra-high-speed volumetric tomography of human retinal blood flow. , 2009, Optics express.

[12]  David Williams,et al.  The arrangement of the three cone classes in the living human eye , 1999, Nature.

[13]  S. Sadda,et al.  Proposed lexicon for anatomic landmarks in normal posterior segment spectral-domain optical coherence tomography: the IN•OCT consensus. , 2014, Ophthalmology.

[14]  Jeehyun Kim,et al.  Handheld Optical Coherence Tomography Scanner for Primary Care Diagnostics , 2011, IEEE Transactions on Biomedical Engineering.

[15]  P. B. Donzis,et al.  Refractive development of the human eye. , 1985, Archives of ophthalmology.

[16]  Sina Farsiu,et al.  Insights into advanced retinopathy of prematurity using handheld spectral domain optical coherence tomography imaging. , 2009, Ophthalmology.

[17]  A. Hendrickson,et al.  Human photoreceptor topography , 1990, The Journal of comparative neurology.

[18]  E. Rossi,et al.  The relationship between visual resolution and cone spacing in the human fovea , 2009, Nature Neuroscience.

[19]  T. Hebert,et al.  Adaptive optics scanning laser ophthalmoscopy. , 2002, Optics express.

[20]  Cynthia A Toth,et al.  Histologic development of the human fovea from midgestation to maturity. , 2012, American journal of ophthalmology.

[21]  Martin F. Kraus,et al.  Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror. , 2013, Biomedical optics express.

[22]  A. Roorda,et al.  Optimal pupil size in the human eye for axial resolution. , 2003, Journal of the Optical Society of America. A, Optics, image science, and vision.

[23]  Christopher S. Langlo,et al.  Automatic detection of modal spacing (Yellott's ring) in adaptive optics scanning light ophthalmoscope images , 2013, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[24]  A. Weiss,et al.  Imaging a child's fundus without dilation using a handheld confocal scanning laser ophthalmoscope. , 2003, Archives of ophthalmology.

[25]  Stephen A Burns,et al.  Individual variations in human cone photoreceptor packing density: variations with refractive error. , 2008, Investigative ophthalmology & visual science.

[26]  Zhuolin Liu,et al.  Modal content of living human cone photoreceptors. , 2015, Biomedical optics express.

[27]  Chris Dainty,et al.  Wide-field schematic eye models with gradient-index lens. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[28]  Jean-Marie Parel,et al.  Human ocular biometry. , 2012, Experimental eye research.

[29]  J. Fujimoto,et al.  Ultrahigh speed spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second. , 2008, Optics express.

[30]  Nathan D. Shemonski,et al.  Computational high-resolution optical imaging of the living human retina , 2015, Nature Photonics.

[31]  A. Hendrickson,et al.  A qualitative and quantitative analysis of the human fovea during development , 1986, Vision Research.

[32]  A. Swaroop,et al.  High-resolution imaging with adaptive optics in patients with inherited retinal degeneration. , 2007, Investigative ophthalmology & visual science.

[33]  D. Wallace,et al.  Retinal imaging in premature infants using the Pictor noncontact digital camera. , 2014, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus.

[34]  Sina Farsiu,et al.  Handheld simultaneous scanning laser ophthalmoscopy and optical coherence tomography system. , 2013, Biomedical optics express.

[35]  D. Wallace,et al.  Imaging the infant retina with a hand-held spectral-domain optical coherence tomography device. , 2009, American journal of ophthalmology.