Fixation of the reversed shoulder prosthesis.

The last decade has seen an increased interest in reversed shoulder prostheses. Success rates with these designs have been varied, with initial performance marred by failures resulting from improper implant alignment and an emerging engineering understanding. Competitor products to the well-documented Grammont design have yielded increasingly high success rates. Understanding the relationships between implant design, surgical procedure, and clinical outcome is important so that current results can be improved upon. This study considers the performance of 3 different reversed shoulder designs from the perspective of osseointegration, with the results broadly validated through comparison with experimental data. Finite element modeling was used to clarify the relationships between lateral offset of the center of rotation, screw insertion angle, screw length, screw diameter, bone material quality, and the potential for interdigitation of the supporting bone onto the reversed prosthesis. The results indicate that screw length, insertion angle, and diameter, when maximized, allow the least relative motion between the implant and underlying bone. When the bone is stiffer, the relative motion of the implant is lower. In almost all scenarios modeled, the interface micromotion was small enough to suggest that the glenoid was stable enough to encourage bone ingrowth across the majority of the bone-implant interfaces.

[1]  G Walch,et al.  Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders. , 2004, The Journal of bone and joint surgery. British volume.

[2]  Christian Gerber,et al.  Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. , 2005, Journal of shoulder and elbow surgery.

[3]  Gilles Walch,et al.  The Influence of Glenohumeral Prosthetic Mismatch on Glenoid Radiolucent Lines: Results of a Multicenter Study , 2002, The Journal of bone and joint surgery. American volume.

[4]  P. Grammont,et al.  Delta shoulder prosthesis for rotator cuff rupture. , 1993, Orthopedics.

[5]  Matthew Vasey,et al.  The Reverse Shoulder Prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. A minimum two-year follow-up study of sixty patients. , 2005, The Journal of bone and joint surgery. American volume.

[6]  F A Matsen,et al.  Prosthetic replacement of the shoulder for the treatment of defects in the rotator cuff and the surface of the glenohumeral joint. , 1993, The Journal of bone and joint surgery. American volume.

[7]  C Gerber,et al.  Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis. , 2005, The Journal of bone and joint surgery. American volume.

[8]  R. Huiskes,et al.  Friction and stem stiffness affect dynamic interface motion in total hip replacement , 1996, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[9]  Mark Taylor,et al.  Glenohumeral kinematics following total shoulder arthroplasty: A finite element investigation , 2007, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[10]  G. Walch,et al.  Reverse total shoulder arthroplasty. Survivorship analysis of eighty replacements followed for five to ten years. , 2006, The Journal of bone and joint surgery. American volume.

[11]  C A Rockwood,et al.  Complications of total shoulder-replacement arthroplasty. , 1996, The Journal of bone and joint surgery. American volume.

[12]  P J Prendergast,et al.  Structural analysis of an offset-keel design glenoid component compared with a center-keel design. , 2001, Journal of shoulder and elbow surgery.

[13]  J. E. Akin,et al.  Effect of porous coating and loading conditions on total hip femoral stem stability. , 1995, The Journal of arthroplasty.

[14]  G. Walch,et al.  9: Complications and revision of the reverse prosthesis: A multicenter study of 457 cases , 2007 .

[15]  M. Dauty,et al.  Prothèse totale inversée de l'épaule et insuffisance de la coiffe des rotateurs : évaluation et approche de paramètres anatomiques prédictifs d'une bonne fonctionnalité à propos de 21 cas , 2001 .

[16]  T. Kaufler,et al.  Analysis of glenoid component fixation designs in the rheumatoid scapula , 1998 .

[17]  Mark Taylor,et al.  Wear in the prosthetic shoulder: association with design parameters. , 2007, Journal of biomechanical engineering.

[18]  S. B. Mostofi,et al.  Biomechanical considerations of the normal and rotator cuff deficient shoulders and the reverse shoulder prosthesis , 2007 .

[19]  P J Prendergast,et al.  Three-dimensional finite element analysis of glenoid replacement prostheses: a comparison of keeled and pegged anchorage systems. , 2000, Journal of biomechanical engineering.

[20]  D R Pichora,et al.  Mechanical testing of shoulder prostheses and recommendations for glenoid design. , 2000, Journal of shoulder and elbow surgery.

[21]  Mark Taylor,et al.  Initial stability of ankle arthrodesis with three-screw fixation. A finite element analysis. , 2004, Clinical biomechanics.

[22]  I. Babuska,et al.  Finite Element Analysis , 2021 .

[23]  E A Audenaert,et al.  Shoulder prostheses treating cuff tear arthropathy: A comparative biomechanical study , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[24]  Scott Banks,et al.  Initial glenoid component fixation in "reverse" total shoulder arthroplasty: a biomechanical evaluation. , 2005, Journal of shoulder and elbow surgery.

[25]  W H Harris,et al.  Factors influencing stability at the interface between a porous surface and cancellous bone: a finite element analysis of a canine in vivo micromotion experiment. , 1997, Journal of biomedical materials research.

[26]  Jonathan C. Levy,et al.  Center of Rotation Affects Abduction Range of Motion of Reverse Shoulder Arthroplasty , 2007, Clinical orthopaedics and related research.

[27]  J. M. Lee,et al.  Observations on the Effect of Movement on Bone Ingrowth into Porous‐Surfaced Implants , 1986, Clinical orthopaedics and related research.

[28]  F.C.T. van der Helm The ‘reversed’ glenohumeral endoprosthesis: The role of the rotator cuff muscles for stability and strength , 1998 .

[29]  P S Walker,et al.  Analysis of glenoid fixation for a reversed anatomy fixed-fulcrum shoulder replacement. , 2004, Journal of biomechanics.

[30]  C A Rockwood,et al.  Hemiarthroplasty in rotator cuff-deficient shoulders. , 1996, Journal of shoulder and elbow surgery.

[31]  U. Wyss,et al.  Review of arm motion analyses , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[32]  D. Pichora,et al.  Glenoid cancellous bone strength and modulus. , 1999, Journal of biomechanics.

[33]  A. Amis,et al.  The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty. , 2004, Journal of shoulder and elbow surgery.

[34]  R. Cofield,et al.  Shoulder Hemiarthroplasty for Glenohumeral Arthritis Associated with Severe Rotator Cuff Deficiency , 2001, The Journal of bone and joint surgery. American volume.

[35]  Jui-Ting Hsu,et al.  The relation between micromotion and screw fixation in acetabular cup , 2006, Comput. Methods Programs Biomed..

[36]  R. Emery Surgery to the shoulder--shoulder replacement. , 1995, British journal of rheumatology.