Electroanalytical biosensors and their potential for food pathogen and toxin detection

The detection and identification of foodborne pathogens continue to rely on conventional culturing techniques. These are very elaborate, time-consuming, and have to be completed in a microbiology laboratory and are therefore not suitable for on-site monitoring. The need for a more rapid, reliable, specific, and sensitive method of detecting a target analyte, at low cost, is the focus of a great deal of research. Biosensor technology has the potential to speed up the detection, increase specificity and sensitivity, enable high-throughput analysis, and to be used for monitoring of critical control points in food production. This article reviews food pathogen detection methods based on electrochemical biosensors, specifically amperometric, potentiometric, and impedimetric biosensors. The underlying principles and application of these biosensors are discussed with special emphasis on new biorecognition elements, nanomaterials, and lab on a chip technology.

[1]  Miri Yemini,et al.  Specific electrochemical phage sensing for Bacillus cereus and Mycobacterium smegmatis. , 2007, Bioelectrochemistry.

[2]  J R Scherer,et al.  Integrated portable genetic analysis microsystem for pathogen/infectious disease detection. , 2004, Analytical chemistry.

[3]  A. Gehring,et al.  PROTEIN-BASED MICROARRAY FOR THE DETECTION OF PATHOGENIC BACTERIA1 , 2007 .

[4]  Roger J Lewis,et al.  Rapid electrochemical detection and identification of catalase positive micro-organisms. , 2003, Biosensors & bioelectronics.

[5]  A. Gehring,et al.  Use of a light-addressable potentiometric sensor for the detection of Escherichia coli O157:H7. , 1998, Analytical biochemistry.

[6]  A. Merkoçi,et al.  Electrochemical genosensor design: immobilisation of oligonucleotides onto transducer surfaces and detection methods. , 2000, Biosensors & bioelectronics.

[7]  G. Palleschi,et al.  Disposable immunosensor for the determination of domoic acid in shellfish. , 2004, Biosensors & bioelectronics.

[8]  M. Slavik,et al.  Detection of Campylobacter jejuni in poultry samples using an enzyme-linked immunoassay coupled with an enzyme electrode. , 2001, Biosensors & bioelectronics.

[9]  Sylvia Kwakye,et al.  Electrochemical microfluidic biosensor for nucleic acid detection with integrated minipotentiostat. , 2006, Biosensors & bioelectronics.

[10]  P Atanasov,et al.  Flow-through immunofiltration assay system for rapid detection of E. coli O157:H7. , 1999, Biosensors & bioelectronics.

[11]  A. Bhunia,et al.  Microscale electronic detection of bacterial metabolism , 2002 .

[12]  E. Alocilja,et al.  A high density microelectrode array biosensor for detection of E. coli O157:H7. , 2005, Biosensors & bioelectronics.

[13]  J. W. Parce,et al.  Light-addressable potentiometric sensor for biochemical systems. , 1988, Science.

[14]  Isao Karube,et al.  Disposable amperometric CO2 sensor employing bacteria and a miniature oxygen electrode , 1991 .

[15]  Joseph Wang Electrochemical nucleic acid biosensors , 2002 .

[16]  A. Gehring,et al.  Immunoelectrochemical assays for bacteria: use of epifluorescence microscopy and rapid-scan electrochemical techniques in development of an assay for Salmonella. , 1996, Analytical chemistry.

[17]  E. Alocilja,et al.  Market analysis of biosensors for food safety. , 2003, Biosensors & bioelectronics.

[18]  John Elmerdahl Olsen,et al.  DNA-based methods for detection of food-borne bacterial pathogens , 2000 .

[19]  G G Guilbault,et al.  Demonstration of labeless detection of food pathogens using electrochemical redox probe and screen printed gold electrodes. , 2003, Biosensors & bioelectronics.

[20]  Lucia Mosiello,et al.  Escherichia coli detection in vegetable food by a potentiometric biosensor , 2003 .

[21]  Giuseppe Palleschi,et al.  Development of an Electrochemical Immunosensor for Ochratoxin A , 2004 .

[22]  G. Volpe,et al.  A RAPID ELECTROCHEMICAL ELISA FOR THE DETECTION OF SALMONELLA IN MEAT SAMPLES , 2001 .

[23]  M. Slavik,et al.  Rapid detection of Salmonella typhimurium in chicken carcass wash water using an immunoelectrochemical method. , 2000, Journal of food protection.

[24]  C. Cutter,et al.  Use of a Rapid Microbial ATP Bioluminescence Assay to Detect Contamination on Beef and Pork Carcasses †. , 1995, Journal of food protection.

[25]  Eliora Z Ron,et al.  Amperometric quantification of total coliforms and specific detection of Escherichia coli. , 2002, Analytical chemistry.

[26]  Qin Pan,et al.  Aptamers That Preferentially Bind Type IVB Pili and Inhibit Human Monocytic-Cell Invasion by Salmonella enterica Serovar Typhi , 2005, Antimicrobial Agents and Chemotherapy.

[27]  B. D. Malhotra,et al.  Recent developments in bio-molecular electronics techniques for food pathogens. , 2006, Analytica chimica acta.

[28]  Jean-Louis Marty,et al.  Highly sensitive amperometric immunosensors for microcystin detection in algae. , 2007, Biosensors & bioelectronics.

[29]  Dmitri Ivnitski,et al.  Biosensors for detection of pathogenic bacteria , 1999 .

[30]  Ihab Abdel-Hamid,et al.  Application of Electrochemical Biosensors for Detection of Food Pathogenic Bacteria , 2000 .

[31]  M. Levy,et al.  Peptide nucleic acids rather than RNA may have been the first genetic molecule. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[32]  B. Dunn,et al.  A MEMS based amperometric detector for E. coli bacteria using self-assembled monolayers. , 2001, Biosensors & bioelectronics.

[33]  D. Lim,et al.  Detection of microorganisms and toxins with evanescent wave fiber-optic biosensors , 2003, Proc. IEEE.

[34]  Miloslav Pravda,et al.  Development of Polyclonal Antibodies Against Domoic Acid for Their Use in Electrochemical Biosensors , 2003 .

[35]  D. Bánáti,et al.  The EU and candidate countries: How to cope with food safety policies? , 2003 .

[36]  J. Pingarrón,et al.  In-a-day electrochemical detection of coliforms in drinking water using a tyrosinase composite biosensor. , 2005, Analytical chemistry.

[37]  S. Maiti,et al.  Thermodynamic, counterion, and hydration effects for the incorporation of locked nucleic acid nucleotides into DNA duplexes. , 2006, Biochemistry.

[38]  Richard A Montagna,et al.  Microfluidic biosensor for the serotype-specific detection of dengue virus RNA. , 2005, Analytical chemistry.

[39]  K. Dill,et al.  Detection of salmonella in poultry using a silicon chip-based biosensor. , 1999, Journal of biochemical and biophysical methods.

[40]  S. Hernández,et al.  In situ DNA amplification with magnetic primers for the electrochemical detection of food pathogens. , 2007, Biosensors & bioelectronics.

[41]  Evangelyn C. Alocilja,et al.  A Disposable Biosensor for Pathogen Detection in Fresh Produce Samples , 2004 .

[42]  E. Paleček,et al.  Past, present and future of nucleic acids electrochemistry. , 2002, Talanta.

[43]  Chuanmin Ruan,et al.  A bienzyme electrochemical biosensor coupled with immunomagnetic separation for rapid detection of Escherichia coli O157:H7 in food samples , 2002 .

[44]  G. Marrazza,et al.  Disposable electrochemical genosensor for the simultaneous analysis of different bacterial food contaminants. , 2007, Biosensors & bioelectronics.

[45]  Shaoping Deng,et al.  A disposable amperometric enzyme immunosensor for rapid detection of Vibrio parahaemolyticus in food based on agarose/Nano-Au membrane and screen-printed electrode , 2007 .

[46]  Chin-Yi Chen,et al.  Single-chain Fv antibody with specificity for Listeria monocytogenes. , 2004, Journal of immunological methods.

[47]  R. Beumer,et al.  Methodology for detection and typing of foodborne microorganisms. , 1999, International journal of food microbiology.

[48]  Ashok Mulchandani,et al.  Amperometric microbial biosensor for p-nitrophenol using Moraxella sp.-modified carbon paste electrode. , 2005, Biosensors & bioelectronics.

[49]  Piet Bergveld,et al.  Thirty years of ISFETOLOGY ☆: What happened in the past 30 years and what may happen in the next 30 years , 2003 .

[50]  Yanbin Li,et al.  Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium. , 2004, Biosensors & bioelectronics.

[51]  A. Gehring,et al.  Enzyme-linked immunomagnetic electrochemical detection of Salmonella typhimurium. , 1996, Journal of immunological methods.

[52]  G. Palleschi,et al.  Electrochemical immunosensor array using a 96-well screen-printed microplate for aflatoxin B1 detection. , 2007, Biosensors & bioelectronics.

[53]  Stephen J. Forsythe,et al.  Hazard analysis critical control point and prerequisite programme implementation in small and medium size food businesses , 2003 .

[54]  R. O'Kennedy,et al.  Advances in biosensors for detection of pathogens in food and water , 2003 .

[55]  M. Mascini,et al.  Aptamers-based assays for diagnostics, environmental and food analysis. , 2007, Biomolecular engineering.

[56]  G. Palleschi,et al.  Development and Comparative Evaluation of Different Screening Methods for Detection of Staphylococcus aureus , 2005 .

[57]  A. Baeumner,et al.  RNA biosensor for the rapid detection of viable Escherichia coli in drinking water. , 2003, Biosensors & bioelectronics.

[58]  Joy L. Brooks,et al.  A semi-homogeneous amperometric immunosensor for protein A-bearing Staphylococcus aureus in foods , 1990, Applied Microbiology and Biotechnology.

[59]  G. Marrazza,et al.  Carbon and gold electrodes as electrochemical transducers for DNA hybridisation sensors. , 2004, Biosensors & bioelectronics.

[60]  Kagan Kerman,et al.  Recent trends in electrochemical DNA biosensor technology , 2004 .

[61]  A P Turner,et al.  Immunomagnetic separation with mediated flow injection analysis amperometric detection of viable Escherichia coli O157. , 1998, Analytical chemistry.

[62]  J. Brewster,et al.  Filtration capture and immunoelectrochemical detection for rapid assay of Escherichia coli O157:H7. , 1998, Journal of immunological methods.

[63]  Paul Leonard,et al.  Applications and Recent Developments in the use of Antibodies for Analysis , 2000 .

[64]  J. Kiel,et al.  Anti-Francisella tularensis DNA aptamers detect tularemia antigen from different subspecies by Aptamer-Linked Immobilized Sorbent Assay , 2006, Laboratory Investigation.

[65]  Avraham Rasooly,et al.  Biosensors for the analysis of food- and waterborne pathogens and their toxins. , 2006, Journal of AOAC International.

[66]  Marco Mascini,et al.  Rapid detection of Escherichia coli in water by a culture-based amperometric method , 2001 .

[67]  Yanbin Li,et al.  Rapid detection of viable Salmonella typhimurium in a selective medium by monitoring oxygen consumption with electrochemical cyclic voltammetry , 2002 .

[68]  A. Baeumner,et al.  Application of a unique server-based oligonucleotide probe selection tool toward a novel biosensor for the detection of Streptococcus pyogenes. , 2007, Biosensors & bioelectronics.

[69]  Olivier Lazcka,et al.  Pathogen detection: a perspective of traditional methods and biosensors. , 2007, Biosensors & bioelectronics.

[70]  R. Hintsche,et al.  Automated detection and quantitation of bacterial RNA by using electrical microarrays. , 2006, Analytical chemistry.

[71]  S. Yaron,et al.  A reverse transcriptase‐polymerase chain reaction assay for detection of viable Escherichia coli O157:H7: investigation of specific target genes , 2002, Journal of applied microbiology.

[72]  A. Baeumner,et al.  A microfluidic biosensor based on nucleic acid sequence recognition , 2003, Analytical and bioanalytical chemistry.

[73]  J. Ho,et al.  Electrochemical immunosensor for cholera toxin using liposomes and poly(3,4-ethylenedioxythiophene)-coated carbon nanotubes. , 2006, Analytical chemistry.

[74]  E. Alocilja,et al.  Nanowire labeled direct-charge transfer biosensor for detecting Bacillus species. , 2007, Biosensors & bioelectronics.