Acoustic attenuation compensation in photoacoustic tomography using time-variant filtering

Abstract. Most reconstruction algorithms used in photoacoustic tomography do not account for the effects of acoustic attenuation on the recorded signals. For experimental measurements made in biological tissue, the frequency dependent acoustic attenuation causes high frequency components of the propagating photoacoustic waves to be significantly reduced. This signal loss manifests as a depth dependent magnitude error and blurring of features within the reconstructed image. Here, a general method for compensating for this attenuation using time-variant filtering is presented. The time-variant filter is constructed to correct for acoustic attenuation and dispersion following a frequency power law under the assumption the distribution of attenuation parameters is homogeneous. The filter is then applied directly to the recorded time-domain signals using a form of nonstationary convolution. Regularization is achieved using a time-variant window where the cutoff frequency is based on the local time-frequency distribution of the recorded signals. The approach is computationally efficient and can be used in combination with any detector geometry or reconstruction algorithm. Numerical and experimental examples are presented to illustrate the utility of the technique. Clear improvements in the magnitude and resolution of reconstructed photoacoustic images are seen when acoustic attenuation compensation is applied.

[1]  Bradley E. Treeby,et al.  Fast tissue-realistic models of photoacoustic wave propagation for homogeneous attenuating media , 2009, BiOS.

[2]  Jan Laufer,et al.  Backward-mode multiwavelength photoacoustic scanner using a planar Fabry-Perot polymer film ultrasound sensor for high-resolution three-dimensional imaging of biological tissues. , 2008, Applied optics.

[3]  Lihong V. Wang,et al.  Photoacoustic computed tomography correcting for heterogeneity and attenuation. , 2012, Journal of biomedical optics.

[4]  B. T. Cox,et al.  The challenges for quantitative photoacoustic imaging , 2009, BiOS.

[5]  Hughes,et al.  On the applicability of Kramers-Kronig relations for ultrasonic attenuation obeying a frequency power law , 2000, The Journal of the Acoustical Society of America.

[6]  P. Burgholzer,et al.  Efficient modeling and compensation of ultrasound attenuation losses in photoacoustic imaging , 2010 .

[7]  P. Burgholzer,et al.  Information changes and time reversal for diffusion-related periodic fields , 2009, BiOS.

[8]  J. Mobley,et al.  Causality-imposed (Kramers-Kronig) relationships between attenuation and dispersion , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  S Holm,et al.  Modified Szabo's wave equation models for lossy media obeying frequency power law. , 2003, The Journal of the Acoustical Society of America.

[10]  Patrick J. La Riviere,et al.  Photoacoustic image reconstruction in an attenuating medium using singular-value decomposition , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[11]  P. Burgholzer,et al.  Experimental evaluation of time domain models for ultrasound attenuation losses in photoacoustic imaging. , 2012, The Journal of the Acoustical Society of America.

[12]  M A Srinivasan,et al.  High-frequency ultrasonic attenuation and backscatter coefficients of in vivo normal human dermis and subcutaneous fat. , 2001, Ultrasound in medicine & biology.

[13]  M. Haltmeier,et al.  Thermoacoustic Tomography - Ultrasound Attenuation Artifacts , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[14]  P. L. La Riviere,et al.  Image reconstruction in optoacoustic tomography accounting for frequency-dependent attenuation , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[15]  S. Arridge,et al.  Quantitative spectroscopic photoacoustic imaging: a review. , 2012, Journal of biomedical optics.

[16]  K. Parker,et al.  Absorption and attenuation in soft tissues. II. Experimental results , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  Yanghua Wang,et al.  Inverse Q-filter for seismic resolution enhancement , 2006 .

[18]  R. Kowar Integral equation models for thermoacoustic imaging of acoustic dissipative tissue , 2010, 1002.4731.

[19]  Bradley E Treeby,et al.  Automatic sound speed selection in photoacoustic image reconstruction using an autofocus approach. , 2011, Journal of biomedical optics.

[20]  Patrick J La Rivière,et al.  Image reconstruction in optoacoustic tomography for dispersive acoustic media. , 2006, Optics letters.

[21]  Lihong V. Wang,et al.  Time reversal and its application to tomography with diffracting sources. , 2004, Physical review letters.

[22]  Habib Ammari Optical, ultrasound, and opto-acoustic tomographies , 2012 .

[23]  Geng Ku,et al.  Multiple-bandwidth photoacoustic tomography. , 2004, Physics in medicine and biology.

[24]  Habib Ammari,et al.  Photoacoustic Imaging for Attenuating Acoustic Media , 2012 .

[25]  Vasilis Ntziachristos,et al.  The effects of acoustic attenuation in optoacoustic signals , 2011, Physics in medicine and biology.

[26]  B. Cox,et al.  Modeling power law absorption and dispersion for acoustic propagation using the fractional Laplacian. , 2010, The Journal of the Acoustical Society of America.

[27]  P. Beard Biomedical photoacoustic imaging , 2011, Interface Focus.

[28]  Boualem Boashash,et al.  Time-Frequency Signal Analysis and Processing: A Comprehensive Reference , 2015 .

[29]  Jan Laufer,et al.  In vivo preclinical photoacoustic imaging of tumor vasculature development and therapy. , 2012, Journal of biomedical optics.

[30]  Otmar Scherzer,et al.  Attenuation Models in Photoacoustics , 2012 .

[31]  N. V. Sushilov,et al.  Frequency-domain wave equation and its time-domain solutions in attenuating media. , 2004, The Journal of the Acoustical Society of America.

[32]  Gary F. Margrave,et al.  Theory of nonstationary linear filtering in the Fourier domain with application to time‐variant filtering , 1998 .

[33]  Rakesh,et al.  Determining a Function from Its Mean Values Over a Family of Spheres , 2004, SIAM J. Math. Anal..

[34]  B T Cox,et al.  A k-space Green's function solution for acoustic initial value problems in homogeneous media with power law absorption. , 2011, The Journal of the Acoustical Society of America.

[35]  Da Xing,et al.  Photoacoustic imaging with attenuation rectification of different frequent components of photoacoustic signal , 2005, SPIE/COS Photonics Asia.

[36]  Lihong V. Wang,et al.  Photoacoustic imaging in biomedicine , 2006 .

[37]  Thomas Berer,et al.  Ultrasonic attenuation of biomaterials for compensation in photoacoustic imaging , 2011, BiOS.

[38]  Frank K. Tittel,et al.  Axial resolution of laser opto-acoustic imaging: influence of acoustic attenuation and diffraction , 1998, Photonics West - Biomedical Optics.

[39]  B. Logan,et al.  Reconstructing Interior Head Tissue from X-Ray Transmissions , 1974 .

[40]  Yanghua Wang,et al.  Seismic Inverse Q Filtering , 2008 .

[41]  David C. Henley,et al.  Gabor deconvolution: Estimating reflectivity by nonstationary deconvolution of seismic data , 2011 .

[42]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .

[43]  Mark A. Anastasio,et al.  Ultrasonic attenuation correction in optoacoustic tomography , 2006, SPIE BiOS.

[44]  P. Kuchment,et al.  Mathematics of thermoacoustic tomography , 2007, European Journal of Applied Mathematics.

[45]  S. M. Doherty,et al.  Seismic Data Analysis: Processing, Inversion, and Interpretation of Seismic Data , 2000 .

[46]  Walter J. Riker A Review of J , 2010 .

[47]  B T Cox,et al.  k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields. , 2010, Journal of biomedical optics.

[48]  Edward Z. Zhang,et al.  Acoustic attenuation compensation in photoacoustic tomography: application to high-resolution 3D imaging of vascular networks in mice , 2011, BiOS.

[49]  A. Bhatia,et al.  Ultrasonic Absorption: An Introduction to the Theory of Sound Absorption and Dispersion in Gases, Liquids and Solids , 2012 .

[50]  Bradley E Treeby,et al.  Measurement of the ultrasound attenuation and dispersion in whole human blood and its components from 0-70 MHz. , 2011, Ultrasound in medicine & biology.

[51]  Thomas L. Szabo,et al.  Time domain wave equations for lossy media obeying a frequency power law , 1994 .

[52]  Jan Laufer,et al.  In vivo photoacoustic imaging of mouse embryos. , 2012, Journal of biomedical optics.

[53]  Chao Huang,et al.  Aberration correction for transcranial photoacoustic tomography of primates employing adjunct image data. , 2012, Journal of biomedical optics.

[54]  B. Cox,et al.  Photoacoustic tomography in absorbing acoustic media using time reversal , 2010 .

[55]  Vasilis Ntziachristos,et al.  Correction for acoustic attenuation effects in optoacoustic tomographic reconstructions , 2011, European Conference on Biomedical Optics.

[56]  Robert Nuster,et al.  Compensation of acoustic attenuation for high-resolution photoacoustic imaging with line detectors , 2007, SPIE BiOS.

[57]  Mark M Meerschaert,et al.  Analytical time-domain Green's functions for power-law media. , 2008, The Journal of the Acoustical Society of America.