Methodology for Combined TMS and EEG

The combination of transcranial magnetic stimulation (TMS) with simultaneous electroencephalography (EEG) provides us the possibility to non-invasively probe the brain’s excitability, time-resolved connectivity and instantaneous state. Early attempts to combine TMS and EEG suffered from the huge electromagnetic artifacts seen in EEG as a result of the electric field induced by the stimulus pulses. To deal with this problem, TMS-compatible EEG systems have been developed. However, even with amplifiers that are either immune to or recover quickly from the pulse, great challenges remain. Artifacts may arise from the movement of electrodes, from muscles activated by the pulse, from eye movements, from electrode polarization, or from brain responses evoked by the coil click. With careful precautions, many of these problems can be avoided. The remaining artifacts can be usually reduced by filtering, but control experiments are often needed to make sure that the measured signals actually originate in the brain. Several studies have shown the power of TMS–EEG by giving us valuable information about the excitability or connectivity of the brain.

[1]  P. Merton The silent period in a muscle of the human hand , 1951, The Journal of physiology.

[2]  W. Penfield SOME MECHANISMS OF CONSCIOUSNESS DISCOVERED DURING ELECTRICAL STIMULATION OF THE BRAIN. , 1958, Proceedings of the National Academy of Sciences of the United States of America.

[3]  K. Krnjević,et al.  An inhibitory process in the cerebral cortex , 1966, The Journal of physiology.

[4]  V E Amassian,et al.  An analysis of the activation of motor cortical neurons by surface stimulation. , 1967, Journal of neurophysiology.

[5]  Wade G. Holcomb,et al.  Principles of Applied Biomedical Instrumentation , 1969, The Yale Journal of Biology and Medicine.

[6]  T. Bliss,et al.  Long‐lasting potentiation of synaptic transmission in the dentate area of the anaesthetized rabbit following stimulation of the perforant path , 1973, The Journal of physiology.

[7]  B. MCA. SAVERS,et al.  The Mechanism of Auditory Evoked EEG Responses , 1974, Nature.

[8]  J. Webster,et al.  Minimizing Electrode Motion Artifact by Skin Abrasion , 1977, IEEE Transactions on Biomedical Engineering.

[9]  P. Jannetta,et al.  Trigeminal evoked potentials in humans. , 1980, Electroencephalography and clinical neurophysiology.

[10]  E. Speckmann,et al.  Electrogenesis of cortical DC potentials. , 1980, Progress in brain research.

[11]  A. Barker,et al.  NON-INVASIVE MAGNETIC STIMULATION OF HUMAN MOTOR CORTEX , 1985, The Lancet.

[12]  I. Hashimoto Trigeminal evoked potentials following brief air puff: Enhanced signal‐to‐noise ratio , 1988, Annals of neurology.

[13]  V. Amassian,et al.  Suppression of visual perception by magnetic coil stimulation of human occipital cortex. , 1989, Electroencephalography and clinical neurophysiology.

[14]  V E Amassian,et al.  Comparison of human transcallosal responses evoked by magnetic coil and electrical stimulation. , 1989, Electroencephalography and clinical neurophysiology.

[15]  D. Regan Human brain electrophysiology: Evoked potentials and evoked magnetic fields in science and medicine , 1989 .

[16]  J F Thayer,et al.  Facial muscle activity and EEG recordings: redundancy analysis. , 1991, Electroencephalography and clinical neurophysiology.

[17]  M Hallett,et al.  The heating of metal electrodes during rapid-rate magnetic stimulation: a possible safety hazard. , 1992, Electroencephalography and clinical neurophysiology.

[18]  V E Amassian,et al.  Cerebello-frontal cortical projections in humans studied with the magnetic coil. , 1992, Electroencephalography and clinical neurophysiology.

[19]  R. Ilmoniemi,et al.  BioMag: functional brain and heart research in clinical environment , 1995, Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society.

[20]  C M Epstein,et al.  Magnetic coil suppression of visual perception at an extracalcarine site. , 1996, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[21]  A. Kimura,et al.  Transcranial magnetic stimulation-induced changes in EEG and responses recorded from the scalp of healthy humans. , 1997, Electroencephalography and clinical neurophysiology.

[22]  Peter T. Fox,et al.  Imaging human intra‐cerebral connectivity by PET during TMS , 1997, Neuroreport.

[23]  Alan C. Evans,et al.  Transcranial Magnetic Stimulation during Positron Emission Tomography: A New Method for Studying Connectivity of the Human Cerebral Cortex , 1997, The Journal of Neuroscience.

[24]  R. Ilmoniemi,et al.  Neuronal responses to magnetic stimulation reveal cortical reactivity and connectivity , 1997, Neuroreport.

[25]  G. Schlaug,et al.  Experience and early findings using transcranial magnetic stimulation (TMS) during functional magnetic resonance imaging (fMRI) in humans , 1998, NeuroImage.

[26]  F. L. D. Silva,et al.  Event-related EEG/MEG synchronization and desynchronization: basic principles , 1999, Clinical Neurophysiology.

[27]  V. Nikouline,et al.  The role of the coil click in TMS assessed with simultaneous EEG , 1999, Clinical Neurophysiology.

[28]  Risto Näätänen,et al.  Separation of contamination caused by coil clicks from responses elicited by transcranial magnetic stimulation , 1999, Clinical Neurophysiology.

[29]  K. Nuechterlein,et al.  Cortical oscillations and schizophrenia: timing is of the essence. , 1999, Archives of general psychiatry.

[30]  P. Matthews The effect of firing on the excitability of a model motoneurone and its implications for cortical stimulation , 1999, The Journal of physiology.

[31]  Matthias M. Müller,et al.  MEG gamma band activity in schizophrenia patients and healthy subjects in a mental arithmetic task and at rest , 2000, Clinical Neurophysiology.

[32]  P. König,et al.  Top-down processing mediated by interareal synchronization. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[33]  E M Wassermann,et al.  BOLD‐f MRI response to single‐pulse transcranial magnetic stimulation (TMS) , 2000, Journal of magnetic resonance imaging : JMRI.

[34]  M. Hallett,et al.  Cutaneomotor integration in humans is somatotopically organized at various levels of the nervous system and is task dependent , 2000, Experimental Brain Research.

[35]  S Minoshima,et al.  Lasting cortical activation after repetitive TMS of the motor cortex , 2000, Neurology.

[36]  Risto J. Ilmoniemi,et al.  Ethanol modulates cortical activity: Direct evidence with combined TMS and EEG , 2000, NeuroImage.

[37]  J. Rothwell,et al.  Short latency inhibition of human hand motor cortex by somatosensory input from the hand , 2000, The Journal of physiology.

[38]  T. Paus,et al.  Repetitive Transcranial Magnetic Stimulation of the Human Prefrontal Cortex Induces Dopamine Release in the Caudate Nucleus , 2001, The Journal of Neuroscience.

[39]  Stefano Tamburin,et al.  Cutaneomotor integration in human hand motor areas: somatotopic effect and interaction of afferents , 2001, Experimental Brain Research.

[40]  T. Paus,et al.  Synchronization of neuronal activity in the human primary motor cortex by transcranial magnetic stimulation: an EEG study. , 2001, Journal of neurophysiology.

[41]  D. Le Bihan,et al.  Diffusion tensor imaging: Concepts and applications , 2001, Journal of magnetic resonance imaging : JMRI.

[42]  Erol Başar,et al.  EEG responses to combined somatosensory and transcranial magnetic stimulation , 2001, Clinical Neurophysiology.

[43]  Giovanni Abbruzzese,et al.  Clinical and Research Methods for Evaluating Cortical Excitability , 2002, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[44]  Sauli Savolainen,et al.  Ipsi- and contralateral EEG reactions to transcranial magnetic stimulation , 2002, Clinical Neurophysiology.

[45]  P. Mazzone,et al.  Short-term reduction of intracortical inhibition in the human motor cortex induced by repetitive transcranial magnetic stimulation , 2002, Experimental Brain Research.

[46]  T. Sejnowski,et al.  Dynamic Brain Sources of Visual Evoked Responses , 2002, Science.

[47]  Takashi Maeno,et al.  Effects of transcranial magnetic stimulation on EEG activities , 2002 .

[48]  Mark S. Cohen,et al.  Simultaneous EEG and fMRI of the alpha rhythm , 2002, Neuroreport.

[49]  P. Mazzone,et al.  Direct demonstration of the effects of repetitive transcranial magnetic stimulation on the excitability of the human motor cortex , 2002, Experimental Brain Research.

[50]  Y Kamitani,et al.  Effects of single-pulse transcranial magnetic stimulation (TMS) on functional brain activity: a combined event-related TMS and evoked potential study , 2003, Clinical Neurophysiology.

[51]  G. Tamás,et al.  Identified Sources and Targets of Slow Inhibition in the Neocortex , 2003, Science.

[52]  Seppo Kähkönen,et al.  Alcohol Reduces Prefrontal Cortical Excitability in Humans: A Combined TMS and EEG Study , 2003, Neuropsychopharmacology.

[53]  R. Ilmoniemi,et al.  Modulation of electroencephalographic responses to transcranial magnetic stimulation: evidence for changes in cortical excitability related to movement , 2003, The European journal of neuroscience.

[54]  E. Gordon,et al.  Synchronous Gamma activity: a review and contribution to an integrative neuroscience model of schizophrenia , 2003, Brain Research Reviews.

[55]  G. Tononi,et al.  Sleep and synaptic homeostasis: a hypothesis , 2003, Brain Research Bulletin.

[56]  N. Logothetis,et al.  Spatial Patterns of Spontaneous Local Field Activity in the Monkey Visual Cortex , 2003, Reviews in the neurosciences.

[57]  Takashi Maeno,et al.  Measurement of evoked electroencephalography induced by transcranial magnetic stimulation , 2003 .

[58]  Gregor Thut,et al.  Differential effects of low-frequency rTMS at the occipital pole on visual-induced alpha desynchronization and visual-evoked potentials , 2003, NeuroImage.

[59]  H. Siebner,et al.  Long-lasting increase in corticospinal excitability after 1800 pulses of subthreshold 5 Hz repetitive TMS to the primary motor cortex , 2004, Clinical Neurophysiology.

[60]  P. Fox,et al.  Column‐based model of electric field excitation of cerebral cortex , 2004, Human brain mapping.

[61]  Ankoor S. Shah,et al.  Neural dynamics and the fundamental mechanisms of event-related brain potentials. , 2004, Cerebral cortex.

[62]  Seppo Kähkönen,et al.  The effect of stimulus intensity on brain responses evoked by transcranial magnetic stimulation , 2004, Human brain mapping.

[63]  H. Siebner,et al.  Distinct changes in cortical and spinal excitability following high-frequency repetitive TMS to the human motor cortex , 2005, Experimental Brain Research.

[64]  Thomas Grunwald,et al.  Neural Bases of Cognitive ERPs: More than Phase Reset , 2004, Journal of Cognitive Neuroscience.

[65]  J. Rothwell,et al.  Interhemispheric interaction between human dorsal premotor and contralateral primary motor cortex , 2004, The Journal of physiology.

[66]  Gregor Thut,et al.  A new device and protocol for combining TMS and online recordings of EEG and evoked potentials , 2005, Journal of Neuroscience Methods.

[67]  Alexander Thiel,et al.  Neuroimaging-guided rTMS of the left inferior frontal gyrus interferes with repetition priming , 2005, NeuroImage.

[68]  Stephen M. Smith,et al.  Investigations into resting-state connectivity using independent component analysis , 2005, Philosophical Transactions of the Royal Society B: Biological Sciences.

[69]  Hannu Tiitinen,et al.  Auditory event-related responses are generated independently of ongoing brain activity , 2005, NeuroImage.

[70]  Giorgio Fuggetta,et al.  Modulation of cortical oscillatory activities induced by varying single-pulse transcranial magnetic stimulation intensity over the left primary motor area: A combined EEG and TMS study , 2005, NeuroImage.

[71]  G. Tononi,et al.  Breakdown of Cortical Effective Connectivity During Sleep , 2005, Science.

[72]  Risto J. Ilmoniemi,et al.  Prefrontal TMS produces smaller EEG responses than motor-cortex TMS: implications for rTMS treatment in depression , 2005, Psychopharmacology.

[73]  Manuel Schabus,et al.  A shift of visual spatial attention is selectively associated with human EEG alpha activity , 2005, The European journal of neuroscience.

[74]  Seppo Kähkönen,et al.  MEG and TMS combined with EEG for mapping alcohol effects. , 2005, Alcohol.

[75]  Thomas Kammer,et al.  Electroencephalographic response to transcranial magnetic stimulation in children: Evidence for giant inhibitory potentials , 2005, Annals of neurology.

[76]  Michael Scherg,et al.  Functional imaging and localization of electromagnetic brain activity , 2005, Brain Topography.

[77]  O. Jensen,et al.  Posterior alpha activity is not phase-reset by visual stimuli. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[78]  S. Rombouts,et al.  Consistent resting-state networks across healthy subjects , 2006, Proceedings of the National Academy of Sciences.

[79]  Jean-Francois Mangin,et al.  Modulation of language areas with functional MR image-guided magnetic stimulation , 2006, NeuroImage.

[80]  Steven K. Esser,et al.  A direct demonstration of cortical LTP in humans: A combined TMS/EEG study , 2006, Brain Research Bulletin.

[81]  Gregor Thut,et al.  Electroencephalographic recording during transcranial magnetic stimulation in humans and animals , 2006, Clinical Neurophysiology.

[82]  N. Swerdlow,et al.  Gamma Band Oscillations Reveal Neural Network Cortical Coherence Dysfunction in Schizophrenia Patients , 2006, Biological Psychiatry.

[83]  C. Carter,et al.  Impairments in frontal cortical γ synchrony and cognitive control in schizophrenia , 2006, Proceedings of the National Academy of Sciences.

[84]  Tomáš Paus,et al.  The neural response to transcranial magnetic stimulation of the human motor cortex. I. Intracortical and cortico-cortical contributions , 2006, Experimental Brain Research.

[85]  Rainer Goebel,et al.  The temporal characteristics of motion processing in hMT/V5+: Combining fMRI and neuronavigated TMS , 2006, NeuroImage.

[86]  C. Carter,et al.  Impairments in frontal cortical gamma synchrony and cognitive control in schizophrenia. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[87]  Helmut Laufs,et al.  Where the BOLD signal goes when alpha EEG leaves , 2006, NeuroImage.

[88]  Matcheri S. Keshavan,et al.  Decreased coherence in higher frequency ranges (beta and gamma) between central and frontal EEG in patients with schizophrenia: A preliminary report , 2006, Psychiatry Research.

[89]  C. Miniussi,et al.  Transcranial magnetic stimulation and cortical evoked potentials: A TMS/EEG co-registration study , 2006, Clinical Neurophysiology.

[90]  Juha Silvanto,et al.  Stimulation of the human frontal eye fields modulates sensitivity of extrastriate visual cortex. , 2006, Journal of neurophysiology.

[91]  Seppo Kähkönen,et al.  The novelty value of the combined use of electroencephalography and transcranial magnetic stimulation for neuroscience research , 2006, Brain Research Reviews.

[92]  O. Jensen,et al.  Posterior α activity is not phase-reset by visual stimuli , 2006 .

[93]  R. Ilmoniemi,et al.  Interpreting magnetic fields of the brain: minimum norm estimates , 2006, Medical and Biological Engineering and Computing.

[94]  G. Tononi,et al.  Sleep function and synaptic homeostasis. , 2006, Sleep medicine reviews.

[95]  R. J. Ilmoniemi,et al.  Instrumentation for the measurement of electric brain responses to transcranial magnetic stimulation , 1999, Medical & Biological Engineering & Computing.

[96]  Vladimir Litvak,et al.  Artifact correction and source analysis of early electroencephalographic responses evoked by transcranial magnetic stimulation over primary motor cortex , 2007, NeuroImage.

[97]  Steven Lemm,et al.  A novel mechanism for evoked responses in the human brain , 2007, The European journal of neuroscience.

[98]  Simon Hanslmayr,et al.  Prestimulus oscillations predict visual perception performance between and within subjects , 2007, NeuroImage.

[99]  O. Jensen,et al.  Cross-frequency coupling between neuronal oscillations , 2007, Trends in Cognitive Sciences.

[100]  J. Kaiser,et al.  Human gamma-frequency oscillations associated with attention and memory , 2007, Trends in Neurosciences.

[101]  Juha Heiskala,et al.  Excitation threshold of the motor cortex estimated with transcranial magnetic stimulation electroencephalography , 2007, Neuroreport.

[102]  Simon Hanslmayr,et al.  Alpha phase reset contributes to the generation of ERPs. , 2006, Cerebral cortex.

[103]  Anna C Nobre,et al.  FEF TMS affects visual cortical activity. , 2006, Cerebral cortex.

[104]  Seppo Kähkönen,et al.  Effects of alcohol on TMS-evoked N100 responses , 2007, Journal of Neuroscience Methods.

[105]  Juha Silvanto,et al.  Neural adaptation reveals state‐dependent effects of transcranial magnetic stimulation , 2007, The European journal of neuroscience.

[106]  L. Merabet,et al.  Occipital Transcranial Magnetic Stimulation Has Opposing Effects on Visual and Auditory Stimulus Detection: Implications for Multisensory Interactions , 2007, The Journal of Neuroscience.

[107]  G. Tononi,et al.  TMS-Induced Cortical Potentiation during Wakefulness Locally Increases Slow Wave Activity during Sleep , 2007, PloS one.

[108]  L. Merabet,et al.  Visual Phosphene Perception Modulated by Subthreshold Crossmodal Sensory Stimulation , 2007, The Journal of Neuroscience.

[109]  T. Paus,et al.  Transcranial magnetic stimulation and the challenge of coil placement: A comparison of conventional and stereotaxic neuronavigational strategies , 2008, Human brain mapping.

[110]  Martin Eimer,et al.  Combining TMS and EEG to study cognitive function and cortico–cortico interactions , 2008, Behavioural Brain Research.

[111]  J. Silvanto,et al.  A novel approach for enhancing the functional specificity of TMS: Revealing the properties of distinct neural populations within the stimulated region , 2008, Clinical Neurophysiology.

[112]  Juha Silvanto,et al.  State-Dependency of Transcranial Magnetic Stimulation , 2008, Brain Topography.

[113]  Bruce R. Rosen,et al.  Parallel input makes the brain run faster , 2008, NeuroImage.

[114]  Gregor Thut,et al.  Resting electroencephalogram alpha-power over posterior sites indexes baseline visual cortex excitability , 2008, Neuroreport.

[115]  R. J. Ilmoniemi,et al.  Bilateral changes in excitability of sensorimotor cortices during unilateral movement: Combined electroencephalographic and transcranial magnetic stimulation study , 2008, Neuroscience.

[116]  Debora Brignani,et al.  Modulation of cortical oscillatory activity during transcranial magnetic stimulation , 2008, Human brain mapping.

[117]  J. Karhu,et al.  Efficient reduction of stimulus artefact in TMS–EEG by epithelial short-circuiting by mini-punctures , 2008, Clinical Neurophysiology.

[118]  Risto J. Ilmoniemi,et al.  TMS and electroencephalography: methods and current advances , 2008 .

[119]  G. Tononi,et al.  Measures of Cortical Plasticity after Transcranial Paired Associative Stimulation Predict Changes in Electroencephalogram Slow-Wave Activity during Subsequent Sleep , 2008, The Journal of Neuroscience.

[120]  K. Iramina,et al.  Differences in evoked EEG by transcranial magnetic stimulation at various stimulus points on the head , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[121]  Á. Pascual-Leone,et al.  Spontaneous fluctuations in posterior alpha-band EEG activity reflect variability in excitability of human visual areas. , 2008, Cerebral cortex.

[122]  G. Tononi,et al.  Reduced evoked gamma oscillations in the frontal cortex in schizophrenia patients: a TMS/EEG study. , 2008, American Journal of Psychiatry.

[123]  Paul B. Fitzgerald,et al.  GABA and cortical inhibition in motor and non-motor regions using combined TMS–EEG: A time analysis , 2009, Clinical Neurophysiology.

[124]  M. Bonnard,et al.  Prior intention can locally tune inhibitory processes in the primary motor cortex: direct evidence from combined TMS‐EEG , 2009, The European journal of neuroscience.

[125]  Synnöve Carlson,et al.  Electrophysiological correlates of short-latency afferent inhibition: a combined EEG and TMS study , 2009, Experimental Brain Research.

[126]  Carlo Miniussi,et al.  TMS-EEG co-registration: On TMS-induced artifact , 2009, Clinical Neurophysiology.

[127]  M. Massimini,et al.  Natural Frequencies of Human Corticothalamic Circuits , 2009, The Journal of Neuroscience.

[128]  C. Miniussi,et al.  New insights into rhythmic brain activity from TMS–EEG studies , 2009, Trends in Cognitive Sciences.

[129]  Jyrki P. Mäkelä,et al.  Reproducibility of TMS—Evoked EEG responses , 2009, Human brain mapping.

[130]  D. Kicic,et al.  Probing cortical excitability with transcranial magnetic stimulation , 2009 .

[131]  Rolf Verleger,et al.  On how the motor cortices resolve an inter‐hemispheric response conflict: an event‐related EEG potential‐guided TMS study of the flankers task , 2009, The European journal of neuroscience.

[132]  Á. Pascual-Leone,et al.  A Review of Combined TMS-EEG Studies to Characterize Lasting Effects of Repetitive TMS and Assess Their Usefulness in Cognitive and Clinical Neuroscience , 2009, Brain Topography.

[133]  Rainer Goebel,et al.  Optimizing Functional Accuracy of TMS in Cognitive Studies: A Comparison of Methods , 2009, Journal of Cognitive Neuroscience.

[134]  Nadia Bolognini,et al.  The Oxford Handbook of Transcranial Stimulation , 2010 .

[135]  Marcello Massimini,et al.  General indices to characterize the electrical response of the cerebral cortex to TMS , 2010, NeuroImage.