Comprehensive control strategy for a variable speed cage machine wind generation unit

A comprehensive control strategy, that addresses all three control objectives in a wind generation system, i.e. control of the local bus voltage to avoid voltage rise, capture of the maximum power in the wind and minimization of the power loss in the induction generator is proposed. The control signals are the desired current wave shapes (instantaneous three-phase currents) of the rectifier and the inverter in a double-sided PWM converter system connected between the wind generating unit and the grid. Studies performed on a complete model for a variable speed cage machine wind generation unit, including wind profile, wind turbine, induction generator, PWM converter, local load and transmission line, show that even as the wind speed changes randomly, the proposed control strategy leads the system to the optimum operating conditions.

[1]  Chee-Mun. Ong,et al.  Dynamic simulation of electric machinery : using MATLAB/SIMULINK , 1997 .

[2]  D. J. Atkinson,et al.  Use of Load Control to Regulate Voltage on Distribution Networks with Embedded Generation , 2002, IEEE Power Engineering Review.

[3]  J. G. Slootweg,et al.  Wind Power: Modelling and Impact on Power System Dynamics , 2003 .

[4]  Paul C. Krause,et al.  Analysis of electric machinery , 1987 .

[5]  P. Kundur,et al.  Power system stability and control , 1994 .

[6]  R. Datta,et al.  Variable-Speed Wind Power Generation Using a Doubly Fed Wound Rotor Induction Machine: A Comparison with Alternative Schemes , 2002, IEEE Power Engineering Review.

[7]  D. Leroux,et al.  Field oriented control of induction machine-simulation and realization , 1996, Proceedings of 4th IEEE International Workshop on Advanced Motion Control - AMC '96 - MIE.

[8]  N. Horiuchi,et al.  Torque and power limitations of variable speed wind turbines using pitch control and generator power control , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[9]  Goran Strbac,et al.  Maximising penetration of wind generation in existing distribution networks , 2002 .

[10]  T. W. Reddoch,et al.  Harmonics generated by two variable speed wind generating systems , 1988 .

[11]  Christine Real de Azua Growth in Worldwide and United States Wind Generating Capacity as Compared with Nuclear Capacity , 2000 .

[12]  R. Swisher,et al.  Strong winds on the horizon: wind power comes of age , 2001, Proc. IEEE.

[13]  V. T. Ranganathan,et al.  Variable-Speed Wind Power Generation Using a Doubly Fed Wound Rotor Induction Machine: A Comparison with Alternative Schemes , 2002 .

[14]  V. T. Ranganathan,et al.  A Method of Tracking the Peak Power Points for a Variable Speed Wind Energy Conversion System , 2002, IEEE Power Engineering Review.

[15]  Wilsun Xu,et al.  Control design and dynamic performance analysis of a wind turbine-induction generator unit , 2000 .

[16]  J. Cidras,et al.  Wind speed simulation in wind farms for steady-state security assessment of electrical power systems , 1999 .

[17]  J. W. Smith,et al.  Voltage impacts of distributed wind generation on rural distribution feeders , 2001, 2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294).

[18]  Bimal K. Bose,et al.  Fuzzy logic based intelligent control of a variable speed cage machine wind generation system , 1995 .

[19]  Paul Puleston,et al.  Sliding mode control of wind energy systems with DOIG-power efficiency and torsional dynamics optimization , 2000 .