Pre‐programmed robotic osteotomies for fibula free flap mandible reconstruction: A preclinical investigation

Bony free flap reconstruction of the facial skeleton remains a challenging area of reconstructive surgery. Despite technological advances that have aided planning and execution of these procedures, surgical inaccuracy is not insignificant. One source of error that has not been wholly addressed is that attributable to a human operator. In this study, we investigate the feasibility and accuracy of performing osteotomies robotically in pre‐programmed fashion for fibula free flap mandible reconstruction as a method to reduce inaccuracies related to human error. A mandibular defect and corresponding free fibula flap reconstruction requiring six osteotomies were designed on a CAD platform. A methodology was developed to translate this virtual surgical plan data to a robot (KUKA, Augsburgs, Germany), which then executed osteotomies on three‐dimensional (3D) printed fibula flaps with the aid of dynamic stereotactic navigation. Using high‐resolution computed tomography, the osteotomized segments were compared to the virtually planned segments in order to measure linear and angular accuracy. A total of 18 robotic osteotomies were performed on three 3D printed fibulas. Compared to the virtual preoperative plan, the average linear variation of the osteotomized segments was 1.3 ± 0.4 mm, and the average angular variation was 4.2 ± 1.7°. This preclinical study demonstrates the feasibility of pre‐programmed robotic osteotomies for free fibula flap mandible reconstruction. Preliminarily, this method exhibits high degrees of linear and angular accuracy, and may be of utility in the development of techniques to further improve surgical accuracy. © 2015 Wiley Periodicals, Inc. Microsurgery 36:246–249, 2016.

[1]  Erik J Geiger,et al.  Three-dimensional virtual surgery accuracy for free fibula mandibular reconstruction: planned versus actual results. , 2014, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[2]  K. Weimer,et al.  Computer-Assisted Design and Computer-Assisted Modeling Technique Optimization and Advantages Over Traditional Methods of Osseous Flap Reconstruction , 2013, Journal of Reconstructive Microsurgery.

[3]  M. Hanasono,et al.  Computer‐assisted design and rapid prototype modeling in microvascular mandible reconstruction , 2013, The Laryngoscope.

[4]  Benjamin D Foley,et al.  Mandibular reconstruction using computer-aided design and computer-aided manufacturing: an analysis of surgical results. , 2013, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[5]  Bin Zhang,et al.  Application of CAD/CAM-assisted technique with surgical treatment in reconstruction of the mandible. , 2012, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[6]  Anuja K. Antony,et al.  Use of Virtual Surgery and Stereolithography-Guided Osteotomy for Mandibular Reconstruction with the Free Fibula , 2011, Plastic and reconstructive surgery.

[7]  M. Hanasono,et al.  Midfacial Reconstruction Using Virtual Planning, Rapid Prototype Modeling, and Stereotactic Navigation , 2010, Plastic and reconstructive surgery.

[8]  K. Weimer,et al.  The accuracy of virtual surgical planning in free fibula mandibular reconstruction: comparison of planned and final results. , 2010, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[9]  J Collyer,et al.  Stereotactic navigation in oral and maxillofacial surgery. , 2010, The British journal of oral & maxillofacial surgery.

[10]  L. Smith,et al.  Clinical use of a frameless stereotactic arm: results of 325 cases. , 1995, Journal of neurosurgery.

[11]  R. Sieira Gil,et al.  Surgical planning and microvascular reconstruction of the mandible with a fibular flap using computer-aided design, rapid prototype modelling, and precontoured titanium reconstruction plates: a prospective study. , 2015, The British journal of oral & maxillofacial surgery.

[12]  J. Polley,et al.  Leveling of the occlusal plane during model surgery. , 1993, The Journal of craniofacial surgery.