Life-cycle energy analysis of building integrated photovoltaic systems (BiPVs) with heat recovery unit

Building integrated photovoltaic (BiPV) systems generate electricity, but also heat, which is typically wasted and also reduces the efficiency of generation. A heat recovery unit can be combined with a BiPV system to take advantage of this waste heat, thus providing cogeneration. Two different photovoltaic (PV) cell types were combined with a heat recovery unit and analysed in terms of their life-cycle energy consumption to determine the energy payback period. A net energy analysis of these PV systems has previously been performed, but recent improvements in the data used for this study allow for a more comprehensive assessment of the combined energy used throughout the entire life-cycle of these systems to be performed. Energy payback periods between 4 and 16.5 years were found, depending on the BiPV system. The energy embodied in PV systems is significant, emphasised here due to the innovative use of national average input-output (I-O) data to fill gaps in traditional life-cycle inventories, i.e. hybrid analysis. These findings provide an insight into the net energy savings that are possible with a well-designed and managed BiPV system.

[1]  Karl W. Böer,et al.  Advances in Solar Energy , 1985 .

[2]  Wassily Leontief Input-Output Economics , 1966 .

[3]  Peter E.D. Love,et al.  Using national input/output data for embodied energy analysis of individual residential buildings , 2001 .

[4]  J. Guinée,et al.  Environmental Life cycle assessment of linoleum , 2000 .

[5]  Evert Nieuwlaar,et al.  Energy viability of photovoltaic systems , 2000 .

[6]  Raya Mertens,et al.  Energy payback time of crystalline silicon solar modules , 1997 .

[7]  Manfred Lenzen,et al.  A Generalized Input-Output Multiplier Calculus for Australia , 2001 .

[8]  E. A. Alsema,et al.  Energy pay-back time of photovoltaic energy systems: present status and prospects , 1998 .

[9]  Gjalt Huppes,et al.  System boundary selection in life-cycle inventories using hybrid approaches. , 2004, Environmental science & technology.

[10]  Stephen D. Casler Correcting input-output coefficients for capital depreciation , 1983 .

[11]  Morgan Bazilian,et al.  A net energy analysis of cogeneration with building integrated photovoltaic systems (BiPVs) , 2002 .

[12]  Erik Alsema,et al.  Energy requirements of thin-film solar cell modules—a review , 1998 .

[13]  Kazuhiko Kato,et al.  Energy pay‐back time and life‐cycle CO2 emission of residential PV power system with silicon PV module , 1998 .

[14]  E. A. Alsema,et al.  Environmental life-cycle assessment of multicrystalline silicon solar cell modules , 1995 .

[15]  I. Boustead,et al.  Handbook of industrial energy analysis , 1979 .

[16]  Manfred Lenzen,et al.  Endogenising capital: a comparison of two methods , 2004 .

[17]  J. Proops,et al.  Input-output analysis and energy intensities: a comparison of some methodologies , 1977 .

[18]  G. Keoleian,et al.  Application of life‐cycle energy analysis to photovoltaic module design , 1997 .

[19]  Gjalt Huppes,et al.  System Boundary Selection in Life-Cycle Inventories , 2004 .

[20]  Gjalt Huppes,et al.  Missing inventory estimation tool using extended input-output analysis , 2002 .

[21]  G. Treloar Extracting Embodied Energy Paths from Input–Output Tables: Towards an Input–Output-based Hybrid Energy Analysis Method , 1997 .

[22]  Clark W. Bullard,et al.  Net energy analysis : handbook for combining process and input-output analysis , 1976 .

[23]  Gjalt Huppes,et al.  Environmental life cycle assessment of linoleum , 2000 .

[24]  L. H. Trieu,et al.  Australian energy consumption and production: historical trends and projections to 2009-10 , 1995 .

[25]  Manfred Lenzen,et al.  Errors in Conventional and Input‐Output—based Life—Cycle Inventories , 2000 .