Kinematic differences between optical motion capture and biplanar videoradiography during a jump-cut maneuver.

Jumping and cutting activities are investigated in many laboratories attempting to better understand the biomechanics associated with non-contact ACL injury. Optical motion capture is widely used; however, it is subject to soft tissue artifact (STA). Biplanar videoradiography offers a unique approach to collecting skeletal motion without STA. The goal of this study was to compare how STA affects the six-degrees-of-freedom motion of the femur and tibia during a jump-cut maneuver associated with non-contact ACL injury. Ten volunteers performed a jump-cut maneuver while their landing leg was imaged using optical motion capture (OMC) and biplanar videoradiography. The within-bone motion differences were compared using anatomical coordinate systems for the femur and tibia, respectively. The knee joint kinematic measurements were compared during two periods: before and after ground contact. Over the entire activity, the within-bone motion differences between the two motion capture techniques were significantly lower for the tibia than the femur for two of the rotational axes (flexion/extension, internal/external) and the origin. The OMC and biplanar videoradiography knee joint kinematics were in best agreement before landing. Kinematic deviations between the two techniques increased significantly after contact. This study provides information on the kinematic discrepancies between OMC and biplanar videoradiography that can be used to optimize methods employing both technologies for studying dynamic in vivo knee kinematics and kinetics during a jump-cut maneuver.

[1]  Simon M Gianotti,et al.  Incidence of anterior cruciate ligament injury and other knee ligament injuries: a national population-based study. , 2009, Journal of science and medicine in sport.

[2]  Anthony G Schache,et al.  Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity. , 2010, Journal of biomechanics.

[3]  S. Woo,et al.  Measurements of Tibiofemoral Kinematics during Soft and Stiff Drop Landings Using Biplane Fluoroscopy , 2011, The American journal of sports medicine.

[4]  A. J. van den Bogert,et al.  Effect of skin movement on the analysis of skeletal knee joint motion during running. , 1997, Journal of biomechanics.

[5]  Jessica M. Deneweth,et al.  Tibiofemoral Joint Kinematics of the Anterior Cruciate Ligament-Reconstructed Knee During a Single-Legged Hop Landing , 2010, The American journal of sports medicine.

[6]  Edward R. Valstar,et al.  Soft-tissue artefact assessment during step-up using fluoroscopy and skin-mounted markers. , 2008, Journal of biomechanics.

[7]  T P Andriacchi,et al.  A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. , 1998, Journal of biomechanical engineering.

[8]  Joseph J Crisco,et al.  Static and dynamic error of a biplanar videoradiography system using marker-based and markerless tracking techniques. , 2011, Journal of biomechanical engineering.

[9]  A. J. van den Bogert,et al.  Tibiocalcaneal motion during running, measured with external and bone markers. , 1997, Clinical biomechanics.

[10]  R. Marshall,et al.  Important features associated with acute anterior cruciate ligament injury. , 1990, The New Zealand medical journal.

[11]  Joseph J Crisco,et al.  Automatic determination of anatomical coordinate systems for three-dimensional bone models of the isolated human knee. , 2010, Journal of biomechanics.

[12]  P R Cavanagh,et al.  Three-dimensional kinematics of the human knee during walking. , 1992, Journal of biomechanics.

[13]  F. Buczek,et al.  Implications of using hierarchical and six degree-of-freedom models for normal gait analyses. , 2010, Gait & posture.

[14]  Bing Yu,et al.  Understanding and Preventing Noncontact Anterior Cruciate Ligament Injuries , 2006, The American journal of sports medicine.

[15]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[16]  I Söderkvist,et al.  Determining the movements of the skeleton using well-configured markers. , 1993, Journal of biomechanics.

[17]  C. L. Chen,et al.  Segment inertial properties of Chinese adults determined from magnetic resonance imaging. , 2000, Clinical biomechanics.

[18]  A Leardini,et al.  Position and orientation in space of bones during movement: experimental artefacts. , 1996, Clinical biomechanics.

[19]  Tung-Wu Lu,et al.  Effects of soft tissue artifacts on the calculated kinematics and kinetics of the knee during stair-ascent. , 2011, Journal of biomechanics.

[20]  Kevin R Ford,et al.  Gender differences in the kinematics of unanticipated cutting in young athletes. , 2005, Medicine and science in sports and exercise.

[21]  John H Challis,et al.  An objective evaluation of a segmented foot model. , 2009, Gait & posture.

[22]  J. Challis A procedure for determining rigid body transformation parameters. , 1995, Journal of biomechanics.

[23]  Scott Tashman,et al.  In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency. , 2003, Journal of biomechanical engineering.

[24]  J Erik Giphart,et al.  Knee kinematic profiles during drop landings: a biplane fluoroscopy study. , 2011, Medicine and science in sports and exercise.

[25]  B. Boden,et al.  Mechanisms of anterior cruciate ligament injury. , 2000, Orthopedics.

[26]  T. Kepple,et al.  Surface movement errors in shank kinematics and knee kinetics during gait , 1997 .

[27]  D. B. Baier,et al.  X-ray reconstruction of moving morphology (XROMM): precision, accuracy and applications in comparative biomechanics research. , 2010, Journal of experimental zoology. Part A, Ecological genetics and physiology.

[28]  W E Garrett,et al.  Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing. , 2011, Journal of biomechanics.

[29]  J. Lysholm,et al.  Rating systems in the evaluation of knee ligament injuries. , 1985, Clinical orthopaedics and related research.