Biventricular Support with the Jarvik 2000 Axial Flow Pump: A Feasibility Study

Patients with congestive heart failure who are supported with a left ventricular assist device (LVAD) may experience right ventricular dysfunction or failure that requires support with a right ventricular assist device (RVAD). To determine the feasibility of using a clinically available axial flow ventricular assist device as an RVAD, we implanted Jarvik 2000 pumps in the left ventricle and right atrium of two Corriente crossbred calves (approximately 100 kg each) by way of a left thoracotomy and then analyzed the hemodynamic effects in the mechanically fibrillated heart at various LVAD and RVAD speeds. Right atrial implantation of the device required no modification of either the device or the surgical technique used for left ventricular implantation. Satisfactory biventricular support was achieved during fibrillation as evidenced by an increase in mean aortic pressure from 34 mm Hg with the pumps off to 78 mm Hg with the pumps generating a flow rate of 4.8 L/min. These results indicate that the Jarvik 2000 pump, which can provide chronic circulatory support and can be powered by external batteries, is a feasible option for right ventricular support after LVAD implantation and is capable of completely supporting the circulation in patients with global heart failure.

[1]  L. Gray,et al.  Preoperative and postoperative comparison of patients with univentricular and biventricular support with the thoratec ventricular assist device as a bridge to cardiac transplantation. , 1997, The Journal of thoracic and cardiovascular surgery.

[2]  G K Jett Physiology of nonpulsatile circulation: acute versus chronic support. , 1999, ASAIO journal.

[3]  B. Griffith,et al.  Transplant candidate's clinical status rather than right ventricular function defines need for univentricular versus biventricular support. , 1996, The Journal of thoracic and cardiovascular surgery.

[4]  W. Piccione Left ventricular assist device implantation: short and long-term surgical complications. , 2000, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[5]  A. Pavie,et al.  Physiology of univentricular versus biventricular support. , 1996, The Annals of thoracic surgery.

[6]  Satoshi Saito,et al.  First permanent implant of the Jarvik 2000 Heart , 2000, The Lancet.

[7]  M. Oz,et al.  Multicenter clinical evaluation of the heartmate; vented electric left ventricular assist system in patients awaiting heart transplantation. , 2001, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[8]  N. Smedira,et al.  Prediction of right ventricular dysfunction after left ventricular assist device implantation. , 1996, Circulation.

[9]  J M Fuqua,et al.  In vivo evaluation of an intraventricular electric axial flow pump for left ventricular assistance. , 1994, ASAIO journal.

[10]  Friedhelm Beyersdorf,et al.  Implantation of the permanent Jarvik-2000 left ventricular assist device: a single-center experience. , 2002, Journal of the American College of Cardiology.

[11]  R K Jarvik,et al.  Research and development of an implantable, axial-flow left ventricular assist device: the Jarvik 2000 Heart. , 2001, The Annals of thoracic surgery.

[12]  M. Oz,et al.  Use of aprotinin in LVAD recipients reduces blood loss, blood use, and perioperative mortality. , 1995, The Annals of thoracic surgery.

[13]  H Harasaki,et al.  Physiopathological studies of nonpulsatile blood flow in chronic models. , 1983, Transactions - American Society for Artificial Internal Organs.

[14]  N G Smedira,et al.  Preoperative risk factors for right ventricular failure after implantable left ventricular assist device insertion. , 1999, The Annals of thoracic surgery.

[15]  W. Santamore,et al.  Left ventricular contributions to right ventricular systolic function during LVAD support. , 1996, The Annals of thoracic surgery.

[16]  E. Tatsumi,et al.  Influences of nonpulsatile pulmonary flow on pulmonary function. Evaluation in a chronic animal model. , 1994, The Journal of thoracic and cardiovascular surgery.

[17]  M. Oz,et al.  Experience with right ventricular assist devices for perioperative right-sided circulatory failure. , 1996, The Annals of thoracic surgery.

[18]  C. H. Owen,et al.  Effects of the left ventricular assist device on right ventricular function. , 1990, The Journal of thoracic and cardiovascular surgery.

[19]  J M Fuqua,et al.  Development of an implantable ventricular assist system. , 1997, The Annals of thoracic surgery.

[20]  M. Oz,et al.  Right ventricular dysfunction and organ failure in left ventricular assist device recipients: a continuing problem. , 2002, The Annals of thoracic surgery.

[21]  Satoshi Saito,et al.  Circulatory Support for Long-Term Treatment of Heart Failure: Experience With an Intraventricular Continuous Flow Pump , 2002, Circulation.