On the determination of the spatial distribution of deep centers in semiconducting thin films from capacitance transient spectroscopy

It is pointed out that a widely used simple formula may give rise to serious errors in profiling deep level concentrations from capacitance transient experiments. A correction formula is derived based on the space‐charge analysis.

[1]  Y. Zohta C‐V and G‐V characteristics of ion‐implanted MOS structures depending upon the geometrical structure of the implanted region , 1977 .

[2]  Richard Williams Determination of Deep Centers in Conducting Gallium Arsenide , 1966 .

[3]  Y. Zohta Admittance-voltage characteristic of an MOS capacitor formed over p-on-n semiconductor structure , 1980 .

[4]  Yasuhito Zohta,et al.  Frequency dependence of C and ΔV/Δ(C−2) of Schottky barriers containing deep impurities , 1973 .

[5]  D. Losee,et al.  Admittance spectroscopy of impurity levels in Schottky barriers , 1975 .

[6]  P. Bräunlich,et al.  Thermally stimulated relaxation in solids , 1979 .

[7]  D. V. Lang,et al.  Fast capacitance transient appartus: Application to ZnO and O centers in GaP p‐n junctions , 1974 .

[8]  J. Basinski,et al.  Capacitance of Junctions on Gold‐Doped Silicon , 1968 .

[9]  G. Glover Determination of deep levels in semiconductors from C-V measurements , 1972 .

[10]  D. V. Lang,et al.  Capacitance Transient Spectroscopy , 1977 .

[11]  Y. Ohmura,et al.  Determination of the spatial distribution of deep centers from capacitance measurements of pn junctions , 1972 .

[12]  A. Tasch,et al.  Thermal and optical emission and capture rates and cross sections of electrons and holes at imperfection centers in semiconductors from photo and dark junction current and capacitance experiments , 1970 .

[13]  Miyoko O. Watanabe,et al.  Effects of the Growth Conditions on Deep Level Concentration in MOCVD GaAs , 1981 .