A novel technique for on-line location of Partial Discharges on medium voltage cables

In this paper, a simple and efficient procedure to model a medium voltage cable directly in time domain is presented. The proposed methodology, considering the skin effects and dielectric losses, takes into account the frequency-dependent parameters of the line. Based on the estimated propagation speed of the presented model, the laboratory and field testing results show that the accuracy Partial Discharge location of a medium voltage cable can be achieved.

[1]  W. Hauschild Frequency-tuned resonant test systems for HV on-site testing of XLPE cables and SF/sub 6/ insulated apparatus , 1997, Proceedings of 5th International Conference on Properties and Applications of Dielectric Materials.

[2]  van der,et al.  On-line detection and location of partial discharges in medium-voltage power cables , 2005 .

[3]  Matthieu Michel,et al.  On-line partial discharge monitoring in medium voltage underground cables , 2009 .

[4]  Time Domain Modeling and Simulation of Partial Discharges on MV Cables by Vector Fitting Method , 2013 .

[5]  T. Schlick,et al.  VLF testing and diagnosis on medium voltage power cables , 2003, 2003 IEEE 10th International Conference on Transmission and Distribution Construction, Operation and Live-Line Maintenance, 2003. 2003 IEEE ESMO..

[6]  Wei Zhang,et al.  A Technique to Identify the Types of Partial Discharges , 2012, 2012 Asia-Pacific Power and Energy Engineering Conference.

[7]  R. Laur,et al.  Simulation of skin effects and hysteresis phenomena in the time domain , 2001 .

[8]  John J. Soraghan,et al.  A noise reduction technique for on-line detection and location of partial discharges in high voltage cable networks , 2000 .

[9]  T. Sarkar,et al.  Analysis of Multiconductor Transmission Lines , 1988, 31st ARFTG Conference Digest.

[10]  R. Bausiere,et al.  Modeling and simulation of unshielded and shielded energy cables in frequency and time domains , 2006, IEEE Transactions on Magnetics.

[11]  E. Gulski,et al.  PD measurements on-site using oscillating wave test system , 1998, Conference Record of the 1998 IEEE International Symposium on Electrical Insulation (Cat. No.98CH36239).

[12]  Paul Lewin,et al.  Wavelet packet denoising for online partial discharge detection in cables and its application to experimental field results , 2006 .

[13]  Sergio Ledesma-Orozco,et al.  Diagnosis test of power cables using a resonant test system and analysis of partial discharge on site , 2010, 12th IEEE International Power Electronics Congress.

[14]  A. Semlyen,et al.  Rational approximation of frequency domain responses by vector fitting , 1999 .