Feasibility study of CMOS detectors for mammography

We investigated the potential use of CMOS (complementary metal-oxide-semiconductor) imaging detectors with a pixel pitch of 48 μm for mammography. Fundamental imaging characteristics were evaluated in terms of modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). The magnitudes of various image noise sources, such as optical photons, direct x rays unattenuated and scattered x rays from the scintillator, and additive electronic noise, were measured and analyzed. For the analysis of the measurement results, we applied a model describing the signal and noise transfer based on the cascaded linear-systems approach. The direct x-ray was very harmful to the detector noise performance with white noise characteristics in the spatial frequency domain, and which significantly degraded the spatial-frequency-dependent DQE at higher frequencies. Although the use of a fiber-optic plate (FOP) reduces the detector sensitivity and the MTF performance, it enhances the DQE performance by preventing the direct x-ray photons from the absorption within the photodiode array.

[1]  Qihua Zhao,et al.  System performance of a prototype flat-panel imager operated under mammographic conditions. , 2003, Medical physics.

[2]  G Belli,et al.  Physical characteristics of five clinical systems for digital mammography. , 2007, Medical physics.

[3]  Min Kook Cho,et al.  Signal and Noise Characteristics Induced by Unattenuated X Rays from a Scintillator in Indirect-Conversion CMOS Photodiode Array Detectors , 2009, IEEE Transactions on Nuclear Science.

[4]  Thorsten Graeve,et al.  High-resolution CMOS imaging detector , 2001, SPIE Medical Imaging.

[5]  Min Kook Cho,et al.  Characterization of CMOS Pixel Detectors for Digital X-Ray Imaging , 2006 .

[6]  R Turchetta,et al.  Empirical electro-optical and x-ray performance evaluation of CMOS active pixels sensor for low dose, high resolution x-ray medical imaging. , 2007, Medical physics.

[7]  I. Cunningham,et al.  On the Development of Digital Radiography Detectors : A Review , 2008 .

[8]  Min Kook Cho,et al.  Measurements of X-ray Imaging Performance of Granular Phosphors With Direct-Coupled CMOS Sensors , 2008, IEEE Transactions on Nuclear Science.

[9]  Min Kook Cho,et al.  Radiation Effects on the Performance of CMOS Photodiode Array Detectors and the Role of Gain-Offset Corrections , 2009, IEEE Transactions on Nuclear Science.

[10]  Ian A. Cunningham,et al.  Computational engine for development of complex cascaded models of signal and noise in X-ray imaging systems , 2005, IEEE Transactions on Medical Imaging.

[11]  Ho Kyung Kim Generalized cascaded model to assess noise transfer in scintillator-based x-ray imaging detectors , 2006 .