Using high-frequency water quality data to assess sampling strategies for the EU Water Framework Directive

The EU Water Framework Directive (WFD) requires that the ecological and chemical status of water bodies in Europe should be assessed, and action taken where possible to ensure that at least "good" quality is attained in each case by 2015. This paper is concerned with the accuracy and precision with which chemical status in rivers can be measured given certain sampling strategies, and how this can be improved. High-frequency (hourly) chemical data from four rivers in southern England were subsampled to simulate different sampling strategies for four parameters used for WFD classification: dissolved phosphorus, dissolved oxygen, pH and water temperature. These data sub-sets were then used to calculate the WFD classification for each site. Monthly sampling was less precise than weekly sampling, but the effect on WFD classification depended on the closeness of the range of concentrations to the class boundaries. In some cases, monthly sampling for a year could result in the same water body being assigned to three or four of the WFD classes with 95% confidence, due to random sampling effects, whereas with weekly sampling this was one or two classes for the same cases. In the most extreme case, the same water body could have been assigned to any of the five WFD quality classes. Weekly sampling considerably reduces the uncertainties compared to monthly sampling. The width of the weekly sampled confidence intervals was about 33% that of the monthly for P species and pH, about 50% for dissolved oxygen, and about 67% for water temperature. For water temperature, which is assessed as the 98th percentile in the UK, monthly sampling biases the mean downwards by about 1 °C compared to the true value, due to problems of assessing high percentiles with limited data. Low-frequency measurements will generally be unsuitable for assessing standards expressed as high percentiles. Confining sampling to the working week compared to all 7 days made little difference, but a modest improvement in precision could be obtained by sampling at the same time of day within a 3 h time window, and this is recommended. For parameters with a strong diel variation, such as dissolved oxygen, the value obtained, and thus possibly the WFD classification, can depend markedly on when in the cycle the sample was taken. Specifying this in the sampling regime would be a straightforward way to improve precision, but there needs to be agreement about how best to characterise risk in different types of river. These results suggest that in some cases it will be difficult to assign accurate WFD chemical classes or to detect likely trends using current sampling regimes, even for these largely groundwater-fed rivers. A more critical approach to sampling is needed to ensure that management actions are appropriate and supported by data.

[1]  William Dixon,et al.  Review of aquatic monitoring program design , 1996 .

[2]  M. Bowes,et al.  Seasonal nutrient dynamics in a chalk stream: the River Frome, Dorset, UK. , 2005, The Science of the total environment.

[3]  Richard A. Skeffington,et al.  Hydrochemical processes in lowland rivers: insights from in situ, high-resolution monitoring , 2012 .

[4]  Penny J Johnes,et al.  Uncertainties in annual riverine phosphorus load estimation: Impact of load estimation methodology, sampling frequency, baseflow index and catchment population density , 2007 .

[5]  Brian Kronvang,et al.  CHOICE OF SAMPLING STRATEGY AND ESTIMATION METHOD FOR CALCULATING NITROGEN AND PHOSPHORUS TRANSPORT IN SMALL LOWLAND STREAMS , 1996 .

[6]  J. Newman,et al.  The Water Quality of the River Enborne, UK: Observations from High-Frequency Monitoring in a Rural, Lowland River System , 2014 .

[7]  H. Broers,et al.  Water quality status and trends in agriculture-dominated headwaters; a national monitoring network for assessing the effectiveness of national and European manure legislation in The Netherlands , 2014, Environmental Monitoring and Assessment.

[8]  Richard A. Skeffington,et al.  High‐frequency water quality monitoring in an urban catchment: hydrochemical dynamics, primary production and implications for the Water Framework Directive , 2015 .

[9]  Richard J. Williams,et al.  Phosphorus dynamics and productivity in a sewage-impacted lowland chalk stream , 2008 .

[10]  Robert O Strobl,et al.  Network design for water quality monitoring of surface freshwaters: a review. , 2008, Journal of environmental management.

[11]  C Neal,et al.  Changes in water quality of the River Frome (UK) from 1965 to 2009: is phosphorus mitigation finally working? , 2011, The Science of the total environment.

[12]  D.T.E. Hunt,et al.  The chemical analysis of water : general principles and techniques , 1974 .

[13]  C. Neal,et al.  The value of high-resolution nutrient monitoring: A case study of the River Frome, Dorset, UK , 2009 .

[14]  B. Zheng,et al.  Optimization of sampling frequency for routine river water quality monitoring , 2014, Science China Chemistry.

[15]  J. P. Riley,et al.  A modified single solution method for the determination of phosphate in natural waters , 1962 .

[16]  Rachel Cassidy,et al.  Limitations of instantaneous water quality sampling in surface-water catchments: Comparison with near-continuous phosphorus time-series data , 2011 .

[17]  Vincenzo Naddeo,et al.  River water quality assessment: Implementation of non-parametric tests for sampling frequency optimization , 2013 .

[18]  Arthur J Horowitz,et al.  A review of selected inorganic surface water quality-monitoring practices: are we really measuring what we think, and if so, are we doing it right? , 2013, Environmental science & technology.