Immunochemical analysis for dioxins--progress and prospects.

Recent developments in antibody design and sample preparation have considerably enhanced the use of enzyme immunoassay (EIA) as an alternative to the conventional techniques based on gas chromatography and mass spectroscopy for the analysis of the trace organic pollutants polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in source and environmental samples. The EIA-specific sample preparation technique for solid matrices using a compatible extracting solvent coupled with an assay using a more sensitive antibody permits screening of source and environmental samples to be undertaken with minimal sample preparation. EIA has been validated on an increasing range of environmental and source samples as a cost effective I-TEQ screening tool, exploiting the commonly recognised general strengths of immunoassays such as speed, simplicity, low cost and parallel processing of many samples, greatly reducing the number of samples requiring conventional GCMS analysis. Further research and developmental work is required in the areas of sample extraction and extract cleanup to ensure compatibility with the immunoassay from the outset, and to standardise as far as is possible an assay format relevant to the application of interest, covering sample preparation, sample cleanup, quality control, assay procedure and data analysis.

[1]  C. Creaser,et al.  Immunoprobes for polychlorinated dibenzodioxins: Synthesis of immunogen and characterization of antibodies , 1992 .

[2]  W. Funcke,et al.  Determination of PCDFs and PCDDs in fire accidents and laboratory combustion tests involving PVC-containing materials , 1989 .

[3]  H. Fiedler,et al.  Statistical analysis of patterns of PCDDs and PCDFs in stack emission samples and identification of a marker congener , 2000 .

[4]  K. Chae,et al.  Synthesis of 1-amino-3,7,8-trichlorodibenzo-p-dioxin and 1-amino-2,3,7,8-tetrachlorodibenzo-p-dioxin as haptenic compounds. , 1977, Journal of agricultural and food chemistry.

[5]  B D Hammock,et al.  Development of a highly sensitive enzyme-linked immunosorbent assay based on polyclonal antibodies for the detection of polychlorinated dibenzo-p-dioxins. , 1998, Analytical chemistry.

[6]  Kees Olie,et al.  Chlorinated dibenzo-p-dioxins and related compounds in incinerator effluents: A review of measurements and mechanisms of formation , 1980 .

[7]  J. Albaigés,et al.  Analytical techniques in environmental chemistry , 1980 .

[8]  M. Vanderlaan,et al.  An immunoassay for chlorinated dioxins in soils , 1989 .

[9]  L. Stieglitz,et al.  Investigation of different treatment techniques for PCDD/PCDF in fly ash , 1986 .

[10]  F. Hileman,et al.  Physical/chemical properties of 2,3,7,8-TCDD , 1985 .

[11]  K. Chae,et al.  Radioimmunoassay for quantitation of 2,3,7,8-tetrachlorodibenzofuran. , 1980, Analytical chemistry.

[12]  P. Albro,et al.  The use of radioimmunoassay for the detection of polychlorinated dibenzo-p-dioxins in fish samples , 1989 .

[13]  J. Johnson,et al.  Determination of part-per-trillion levels of polychlorinated dibenzofurans and dioxins in environmental samples. , 1984, Analytical chemistry.

[14]  Helmut Greim,et al.  The international toxicity equivalency factor (I-TEF) method of risk assessment for complex mixtures of dioxins and related compounds , 1990 .

[15]  D. Knopp Application of immunological methods for the determination of environmental pollutants in human biomonitoring. A review , 1995 .

[16]  J. Sherry,et al.  Environmental Chemistry: The Immunoassay Option , 1992 .

[17]  T. Nakano,et al.  Measurement of combustion products from liquid PCB waste incinerator , 1987 .

[18]  S. Kennel,et al.  Monoclonal antibodies to chlorinated dibenzo-p-dioxins. , 1986, Toxicology and applied pharmacology.

[19]  K. Olie,et al.  Extraction efficiencies of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans from fly ash , 1981 .

[20]  M. Vanderlaan,et al.  Improvement and application of an immunoassay for screening environmental samples for dioxin contamination , 1988 .

[21]  J. Piskorska-Pliszczynska,et al.  Validation of in vitro bioassays for 2,3,7,8-TCDD equivalents , 1987 .

[22]  Robert O. Harrison,et al.  Measurement of PCDD/F TEQ by Immunoassay: Concept Development and Validation , 1998 .

[23]  R O Harrison,et al.  An immunoassay for TEQ screening of dioxin/furan samples: current status of assay and applications development. , 1997, Chemosphere.

[24]  J. O. Nelson,et al.  Immunoanalysis of agrochemicals : emerging technologies , 1995 .

[25]  M Vanderlaan,et al.  Monoclonal antibodies for dioxin: antibody characterization and assay development. , 1987, Toxicology.

[26]  C. Rappe Analysis of polychlorinated dioxins and furans. , 1984, Environmental science & technology.