Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch.

Tip geometry and placement of rotary blood pump inflow and outflow cannulae influence the dynamics of flow within the ventricle and aortic branch. Cannulation, therefore, directly influences the potential for thrombus formation and end-organ perfusion during ventricular assist device (VAD) support or cardiopulmonary bypass (CPB). The purpose of this study was to investigate the effect of various inflow/outflow cannula tip geometries and positions on ventricular and greater vessel flow patterns to evaluate ventricular washout and impact on cerebral perfusion. Transparent models of a dilated cardiomyopathic ventricle and an aortic branch were reconstructed from magnetic resonance imaging data to allow flow measurements using particle image velocimetry (PIV). The contractile function of the failing ventricle was reproduced pneumatically, and supported with a rotary pump. Flow patterns were visualized around VAD inflow cannulae, with various tip geometries placed in three positions in the ventricle. The outflow cannula was placed in the subclavian artery and at several positions in the aorta. Flow patterns were measured using PIV and used to validate an aortic flow computational fluid dynamic study. The PIV technique indicated that locating the inflow tip in the left ventricular outflow tract improved complete ventricular washout while the tip geometry had a smaller influence. However, side holes in the inflow cannula improved washout in all cases. The PIV results confirmed that the positioning and orientation of the outflow cannula in the aortic branch had a high impact on the flow pattern in the vessels, with a negative blood flow in the right carotid artery observed in some cases. Cannula placement within the ventricle had a high influence on chamber washout. The positioning of the outflow cannula directly influences the flow through the greater vessels, and may be responsible for the occasional reduction in cerebral perfusion seen in clinical CPB.

[1]  H. Sievers,et al.  Hydrodynamics of aortic arch vessels during perfusion through the right subclavian artery. , 2000, The Annals of thoracic surgery.

[2]  W. White,et al.  Neurologic outcomes after coronary artery bypass grafting with and without cardiopulmonary bypass. , 2003, Seminars in thoracic and cardiovascular surgery.

[3]  R. Adrian Particle-Imaging Techniques for Experimental Fluid Mechanics , 1991 .

[4]  P. Herijgers,et al.  Initial experiences with the Impella device in patients with cardiogenic shock - Impella support for cardiogenic shock. , 2003, The Thoracic and cardiovascular surgeon.

[5]  H. Harasaki,et al.  Comparison of pulsatile and non‐pulsatile cardiopulmonary bypass on regional renal blood flow in sheep , 2004, Scandinavian cardiovascular journal : SCJ.

[6]  R. Benkowski,et al.  Suction Detection for the MicroMed DeBakey Left Ventricular Assist Device , 2005, ASAIO journal.

[7]  E. Catena,et al.  Impella recover 100 microaxial left ventricular assist device: the Niguarda experience. , 2004, Transplantation proceedings.

[8]  J. Fraser,et al.  Intraaortic Balloon Pump Counterpulsation and Cerebral Autoregulation: an observational study , 2010, BMC anesthesiology.

[9]  P. Corso,et al.  The impact of aortic manipulation on neurologic outcomes after coronary artery bypass surgery: a risk-adjusted study. , 2004, The Annals of thoracic surgery.

[10]  A Takatsu,et al.  Changes in blood viscosity by heparin and argatroban. , 2001, Thrombosis research.

[11]  Richard D. Keane,et al.  Theory of cross-correlation analysis of PIV images , 1992 .

[12]  B. Griffith,et al.  Proof of concept: hemodynamic response to long-term partial ventricular support with the synergy pocket micro-pump. , 2009, Journal of the American College of Cardiology.

[13]  M. Laumen,et al.  Flow distribution during cardiopulmonary bypass in dependency on the outflow cannula positioning. , 2009, Artificial organs.

[14]  G. V. Van Nooten,et al.  Hydrodynamical Comparison of Aortic Arch Cannulae , 1998, The International journal of artificial organs.

[15]  F. Arabía,et al.  Ventricular assist devices today and tomorrow. , 2010, Journal of cardiothoracic and vascular anesthesia.

[16]  Gino Gerosa,et al.  Influence of inflow cannula length in axial-flow pumps on neurologic adverse event rate: results from a multi-center analysis. , 2008, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[17]  H Reul,et al.  Miniaturized implantable rotary blood pump in atrial-aortic position supports and unloads the failing heart. , 1998, Cardiovascular surgery.

[18]  A Undar,et al.  Pulsatile and nonpulsatile flows can be quantified in terms of energy equivalent pressure during cardiopulmonary bypass for direct comparisons. , 1999, ASAIO journal.

[19]  M. Laumen,et al.  The impact of aortic/subclavian outflow cannulation for cardiopulmonary bypass and cardiac support: a computational fluid dynamics study. , 2009, Artificial organs.

[20]  Stephen Westaby,et al.  Initial Clinical Experience With the Jarvik 2000 Implantable Axial-Flow Left Ventricular Assist System , 2002, Circulation.

[21]  D. Mason,et al.  Reliable Suction Detection for Patients With Rotary Blood Pumps , 2008, ASAIO journal.

[22]  T. Imaizumi,et al.  The effects of pulsatile and nonpulsatile systemic perfusion on renal sympathetic nerve activity in anesthetized dogs. , 1996, The Journal of thoracic and cardiovascular surgery.