CPT AND CPTU DATA FOR SOIL PROFILE INTERPRETATION:REVIEW OF METHODS AND A PROPOSED NEW APPROACH

Cone penetration test (CPT) allows for the soil type to be determined from the measured values of cone resistance (qt) and sleeve friction (fs). Since the cone penetrometer progressed from the mechanical cone to the electrical piezocone (CPTu), the reliability of the determination of soil type also improved by pore pressure (u) measurement. This paper references several published methods of soil profiling. All but two of these apply cone resistance plotted against the friction ratio (Rf). A new method for soil profiling has been developed by plotting effective cone resistance (qE) versus sleeve friction with a compiled database from 20 sites in 5 countries. This paper presents two soil profiling methods based on the piezocone and compares them with three specific cases containing sand, normally consolidated clay and overconsolidated clay. Both methods result in an accurate soil type determination.

[1]  T Lunne,et al.  Laboratory and field evaluation of cone penetrometers , 1988 .

[2]  M. Jefferies,et al.  Use of CPTu to Estimate Equivalent SPT N60 , 1993 .

[3]  Peter K. Robertson,et al.  Use of Piezometer Cone Data , 1986 .

[4]  P. Robertson Soil classification using the cone penetration test , 1990 .

[5]  Peter K. Robertson,et al.  Cone-penetration testing in geotechnical practice , 1997 .

[6]  Z. Zhang,et al.  Statistical to Fuzzy Approach toward CPT Soil Classification , 2000 .

[7]  John H. Schmertmann,et al.  GUIDELINES FOR CONE PENETRATION TEST. (PERFORMANCE AND DESIGN) , 1978 .

[8]  Paul W. Mayne,et al.  Observations on the development of pore-water stresses during piezocone penetration in clays , 1990 .

[9]  I W Searle,et al.  The interpretation of Begemann friction jacket cone results to give soil types and design parameters , 1979 .

[10]  Mohsen M. Baligh,et al.  The piezocone penetrometer , 1981 .

[11]  M Mulabdic,et al.  Piezocone tests in clay , 1991 .

[12]  Abolfazl Eslami,et al.  Pile capacity by direct CPT and CPTu methods applied to 102 case histories , 1997 .

[13]  R. S. Olsen,et al.  Soil Classification Using Electric Cone Penetrometer , 1981 .

[14]  P. K. Robertson,et al.  Current status of the piezocone test : Proc 1st International Symposium on Penetration Testing, ISOPT-1, Orlando, 20–24 March 1988 V1, P93–116. Rotterdam: A A Balkema, 1988 , 1990 .

[15]  Hksp Begemann The use of the static soil Penetrometer in Holland , 1963 .

[16]  Richard J. Finno,et al.  Subsurface Conditions and Pile Installation Data: 1989 Foundation Engineering Congress Test Section , 1989 .

[17]  Nilmar Janbu,et al.  EVALUATION OF SOIL PARAMETERS FROM PIEZOCONE TESTS , 1989 .

[18]  李幼升,et al.  Ph , 1989 .